background image

NTxx23SDHD Camera-back Transmitter Operation Manual 

Broadcast Microwave Services 

 

 

Document Revision History 

Initial release 

March 2011 

Rev. - 

Pin assignement  for data interface added 

August 2011 

Rev. 
2.0 

 

Conventions Used in This Manual 

 

NOTE: Notes provide supplementary information. They are highlighted for emphasis, as in this 
example, and are placed immediately after the relevant text.  

 

CAUTION: Cautions give information which, if strictly followed, will prevent damage to equipment 
or other goods. They are boxed for emphasis, as in this example, and are placed immediately 
preceding the point at which the reader requires them.  

 

WARNING: Warnings give information which, if strictly observed, will prevent personal injury or 
death, or damage to personal property or the environment. They are boxed and shaded for 
emphasis, as in this example, and are placed immediately preceding the point at which the reader 
requires them.  

 

ATTENTION! 

 

DO NOT use right-angle connectors or adapters on the RF Power Out cable assemblies. Right-
angle connectors may have significant RF power loss at the operating frequencies of this system. 

 

FOR ALL BMS TRANSMITTERS – Operation of a BMS transmitter product generally requires a 
license. It is the responsibility of the user to obtain all required operating licenses.  

 

ONLY FOR PRODUCTS AWAITING FCC CERTIFICATION – This device has not been authorized as 
required by the rules of the US Federal Communications Commission. This device is not, and may 
not be, offered for sale or lease, or sold or leased, in the US until authorization is obtained. 

 

Acceptance Test Procedure (ATP) test data results by product serial number are typically shipped 
with all units and indicate the equipment to be operating within advertised specifications. Contact 
BMS to request this data. 

 

Read and Follow Instructions! All safety and operating instructions should be read before this 
product is operated. All operating and use instructions should be followed. This manual should be 
retained for future reference. 

 

EMC Compliance – This equipment is certified to the EMC requirements detailed in the technical 
specifications. To maintain this certification, only use the cables supplied or if in doubt contact 
BMS Customer Service. 

 

Compliance – This device complies with several standards. Please refer to the chapter 1.5  
Specifications,
 in this manual for a complete list of standards.

 

Содержание 11.2531.000

Страница 1: ...NT5723SDHD CAMERA BACK TRANSMITTER Operation Manual Doc No 605 Rev 2 0 ...

Страница 2: ...49 6124 72 39 29 2010 Broadcast Microwave Services All rights reserved This document and the information contained in it is the property of Broadcast Microwaves Services Inc and may be the subject of patents pending and granted It must not be used for commercial purposes nor copied disclosed reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical ph...

Страница 3: ...ing frequencies of this system FOR ALL BMS TRANSMITTERS Operation of a BMS transmitter product generally requires a license It is the responsibility of the user to obtain all required operating licenses ONLY FOR PRODUCTS AWAITING FCC CERTIFICATION This device has not been authorized as required by the rules of the US Federal Communications Commission This device is not and may not be offered for s...

Страница 4: ...ered trademark of Thomson and Télédiffusion de France TDF Europe and is a registered trademark of CCS now Musicam USA Incorporated USA Ethernet is a registered trademark of Xerox Corporation XILINX is a registered trademark of Xilinx Inc Pozidriv is a trademark of European Industrial Services Windows NT Windows XP Windows 7 are registered trademarks of Microsoft Corporation NDS is a trademark of N...

Страница 5: ...he transmitter 1 1 3 Configuring the transmitter 2 1 4 Inputs and outputs 3 1 5 Specifications 4 2 PREVENTIVE MAINTENANCE 6 3 REPAIR SERVICE WARRANTY INFORMATION 7 3 1 Customer Service Contact Information 8 4 8 List of Figures Figure 1 Transmitter control panel 1 Figure 2 Menu structure 2 Figure 3 Waking up the unit s display 3 Figure 4 BMS product label 7 ...

Страница 6: ...tput power 1 1 Display and Control buttons The transmitter uses a side mounted control panel shown below The control buttons are capacitive type buttons and a light pressure is needed to operate them Figure 1 Transmitter control panel 1 2 Using the transmitter When the transmitter is powered on the display will show the letters BMS then once the bootup is completed the frequency and current channe...

Страница 7: ...en after about one minute Figure 2 Menu structure To change any of the settings enter the associated menu by touching the select button Use the up or down arrow buttons to navigate through the menus If you are in a submenu the display will appear as below Two arrows are shown with the different values which can be set If the display OFF time is set to a value between 15 seconds and 240 seconds the...

Страница 8: ...re 3 Waking up the unit s display 1 4 Inputs and outputs BNC f Video in SDI HD SDI 75 Ω BNC f Video in CVBS 75 Ω 4pol Hirose f Audio in 1 GND 2 Audio R 3 Audio L 4 n c 2x Analog audio in Line or Mic Level 4pol Hirose m Data 1 Data in 2 Data TX 3 Data RX 4 GND RS232 SMA f RF out 200mW 50 Ω ...

Страница 9: ... 24 25 29 97 30 50 59 94 60 fps Power Input 12 to 17 5 VDC Consumption approx 16 W Temperature 10 C to 50 C 4 F to 122 F Relative Humidity 5 to 95 Dimensions W x D x H NT5723SDHD without brackets 158 x 80 x 46 mm 6 22 x3 14 x1 81 Weight 390g 0 86 lbs 1 5 1 CE Marking The CE mark is affixed to indicate compliance with the following directives 89 336 EEC of 3 May 1989 on the approximation of the law...

Страница 10: ...tion which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an e...

Страница 11: ...NTxx23SDHD Camera back Transmitter Operation Manual Broadcast Microwave Services 6 2 PREVENTIVE MAINTENANCE There are no preventive maintenance procedures for this product ...

Страница 12: ...anual or such other BMS documentation as may be applicable Any such defect reported to BMS within two years BMS will take reasonable and prompt action to repair or replace such equipment Should any of the components be defective please contact BMS immediately Please have the following information available so we can best serve you Much of this information can be found on the unit s BMS product lab...

Страница 13: ... 866 489 4267 Fax 1 858 391 3049 Web www broadcastmicrowave com E mail sales bms inc com Broadcast Microwave Services Europe GmbH Schwalbacher Str 12 65321 Heidenrod Germany Tel 49 6124 72 39 00 Fax 49 6124 72 39 29 Web www broadcastmicrowave com E mail saleseurope bms inc com Please send feedback on this and other BMS manuals to techpubs bms inc com Register for BMS customer portal at www broadca...

Отзывы: