![background image](http://html.mh-extra.com/html/bmpro/j35a/j35a_owners-manual_2779841023.webp)
23
BATTERY CHARGING MANAGEMENT ALGORITHM
The following describes the Battery Charging Management Algorithm used by the
J35 when charging the caravan battery from a mains power source. The J35 will
operate as described when the caravan loads are connected directly to the J35
and not the caravan battery.
Battery Capacity
Soft Start
Boost + Bulk-Absorption
Float
≤
100AH
6 Hours
5 Hours
6 Hours
150AH
6 Hours
7.5 Hours
6 Hours
200AH
6 Hours
10 Hours
6 Hours
250AH
6 Hours
12.5 Hours
6 Hours
≥
300AH
6 Hours
15 Hours
6 Hours
Table 7:
Timeout for each charging mode, based on battery capacity
Figure 5:
J35 Battery Charging Management Algorithm