5.1.2 Test Parameters
On the left hand side of the display values such as passed and failed counts and measured pressure readings
are displayed. The values can be zeroed by pressing the ‘0’ key when the parameter to be zeroed is selected.
For this program the following parameters may be seen:
1. Pressure 1
- “LIVE” pressure reading for channel 1.
2. Final P % 1
- Final pressure % of the last bottle leak tested in channel 1.
3. Pressure 2
- “LIVE” pressure reading for channel 2.
4. Final P % 2
- Final pressure % of the last bottle leak tested in channel 2.
5. Pressure 3
- “LIVE” pressure reading for channel 3.
6. Final P % 3
- Final pressure % of the last bottle leak tested in channel 3.
7. Pressure 4
- “LIVE” pressure reading for channel 4.
8. Final P % 4
- Final pressure % of the last bottle leak tested in channel 4.
9. Pressure 5
- “LIVE” pressure reading for channel 5.
10. Final P % 5
- Final pressure % of the last bottle leak tested in channel 5.
11. Pressure 6
- “LIVE” pressure reading for channel 6.
12. Final P % 6
- Final pressure % of the last bottle leak tested in channel 6.
13. # Leak Pass
- The number of containers to pass the leak test so far.
14. # Leak Fail
- The number of containers to fail the leaktest so far.
15. Rej Count
- Shows the ‘live’ count of the reject index, this parameter can be used as a rough
guide to ensure that the reject routine is indexing in time with the screw revolutions.
NOTE : The standard screen display has bargraph No. 1 on the far right of the display, depending on
the physical mounting of the operator panel, this may be the same as the physical layout of the
machine, or it may be the other way round, it can be confusing if the screen layout does not match
the physical layout, if the screen layout is the wrong way round it can be reversed by linking IP 7
‘REVERSE DISP’ to 24V on the Input Card in the Operator Panel.