27
Fig. 27.1
Fig. 27.2 - Mod. FLOOR STANDING
Connection to the mains wa-
ter supply
Check that the mains pressure is
between 1 bar and 3,5 bar. To enhance
the quality of the sparkling water
dispensed, an incoming flow rate in
excess of 3.5 l/min is recommended.
If the water pressure is higher than 3,5
bar it is necessary to install a pressure
reducer.
Connect incoming water tube (1)
(Ø9,5mm in mod. F.S. 150 or Ø8mm in
mod. 80 and 30) to the drinking-water
main, ideally with a tap upstream of the
unit.
Once the pipes are attached, turn on
the tap. Ensure there are no leaks.
Before drinking the water from the
system, perform a thorough rinse of the
circuit by dispensing water from each
product line.
CAUTION!
To connect the water cooler to the mains
water supply, you will need to use a new
set of connectors (joints, gaskets and
pipes).
Do not use a set of connectors that has
already been used elsewhere.
The water pressure entering the unit must
be between a minimum of 1,0 bar (0,10
MPa) and a maximum of 3,5 bar (0,35
MPa).
On Beer Tap models, for a proper
installation of the system, the use of the
Water Block is compulsory (cod. 140065).