IP50HD
USER MANUAL
www.blustream.com.au
|
www.blustream-us.com
|
www.blustream.co.uk
14
Configuring the IP50HD-RX:
1) Power the IP50HD Receiver
- to configure the Multicast Receiver first connect the product to a power supply (local
or PoE network) and wait for the product to boot up. The front panel LED display will rotate whilst booting and display
a 2 digit number when complete. This will be '00' if the unit has default settings.
2) Put the IP50HD-RX into 'Local Configuration' mode
- once the product is powered press both the 'UP' and
'DOWN' Channel Select buttons on the front panel at the same time for 6 seconds to enter 'Local Configuration' mode.
The LCD front display of the product will show '
LC
' when it is in this mode.
3) Assign the Receiver ID (IP address)
- once the product is in Local Configuration (LC) mode the display will begin
to flash with a lowercase 'r' to indicate the receivers identity is going to be assigned. The identity will also be the IP
address that is automatically assigned, so is of utmost importance that an individual ID not equal to another RX unit in
the system is assigned:
- The first Receiver ID assigned is ID001 = 169.254.6.1 (IP address 1)
- The second Receiver ID is ID002 = 169.254.6.2 (IP address 2)
and so on....
Once the ID number has been selected and is correct, confirm the selection by pressing both Channel 'UP' and 'DOWN'
buttons at the same time to move on to setting the scaled output.
4) Set the Video Scaler of the Receiver
- once the product ID has been configured the display will begin to flash with
an 's' to indicate that the scaler output is next to be configured. Use the 'UP' or 'DOWN' arrows to select the scaler set-
ting required. A full list of scaler settings can be found in 'Scaler Output Control' section of this manual.
For example: if the display shows '01' the Scaler output will be 1080p 60Hz.
Once the Scaler output that is required for the display connected to the HDMI output of the RX has been set, press both
Channel 'UP' and 'DOWN' buttons at the same time to move onto setting permissions.
5) Setting Permissions
- after the scaler output has been set, the permissions of the Receiver now need to be
configured. The display in the unit will start to flash with the letters 'CH'. Use the 'UP' or 'DOWN' arrows to select the
maximum channel permission number required.
Maximum channel permissions allow for the Receiver to be set up so that it can / cannot access Transmitters within
the system. If the system has 6x TX units and the max channel permissions of the RX is set to 05, the Receiver will have
access to the first 5x transmitters (ID's 001 - 005) and not any other Transmitter after. The number set will equal the last
Transmitter in the system that can be accessed.
Setting the permission value to '00' ignores the permissions and will mean that the Receiver being manually configur-
ing can therefore access ALL transmitters in the system.
Once the permission value required has been selected, press both Channel 'UP' and 'DOWN' buttons to finalise the
manual configuration.
The Multicast Receiver will then reboot with the new settings applied.
Содержание Multicast IP50HD-RX
Страница 1: ...Blustream Multicast IP50HD TX RX User Manual M U L T I C A S T RevA1_IP50_Manual_210604...
Страница 29: ...IP50HD USER MANUAL Contact support blustream com au support blustream us com support blustream co uk 29 Notes...