StarFish 453OEM
System Manual
9
2.6.
Transducer Connections
The StarFish electronic circuit board is pre-
fitted with the transducer cable loom connected to “J1”. Once the
transducers have been mounted and sealed into the housing, they should be connected as shown in the diagram
below to the electronics module:
The grey cabl
es from the circuit board are labelled with “Port” and “Starboard” to indicate which transducer they
should be connected to. However, in case the labels are missing, the Starboard transducer should be connected
to the Yellow & Green wiring pair, while the Port transducer should be connected to the Red & Blue wires.
Wire
Function
Wire
Colour
Starboard
Connector Pin
Port
Connector Pin
J1
Connector Pin
Ground
Black
1
-
4
Not Used
2
-
-
Starboard
Yellow
3
-
6
Starboard Signal-
Green
4
-
5
Ground
Black
-
1
3
Not Used
-
2
-
Port
Red
-
3
1
Port Signal-
Blue
-
4
2