![Blue-White CHEM-FEED CFWS Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/blue-white/chem-feed-cfws-series/chem-feed-cfws-series_operating-manual_2777001008.webp)
5.0
Mounting Pump to the Chem-Feed® System
Page 8
®
CHEM-FEED CFWS
Socket Head
Screw, SS #10-32 - .625”
#10 washer, and 10-32 nut.
(Qty: 4 of each per pump)
6.0
Mounting the Chem-Feed® System
1. Locate mounting position of skid on wall.
2. Use dimensions and strut to mark best location for wall anchors.
3. Remove strut from skid, and mount to wall with anchors.
4. Re-mount skid to strut.
5. Mount pump(s).
Mounting Bracket
(Qty: 2 per pump)
7.0
Component Identification and Typical Operation - Simplex Pump Skid
* PRV = Pressure Relief Valve preset at 50psi
Chemical
Output
Pressure Gauge
Chemical Feed
Flowmeter
(optional)
One way
Check Valve
(with union)
Calibration
Cylinder
Pulse
Dampener
(optional)
Chemical
Input
Y Strainer
PRV*
Gauge
Guard
Page 9
®
CHEM-FEED CFWS
V1
V8
V7
V5
V4
V3
V2
V6
Pressure Switch
(optional)
Back Pressure Valve
(optional)