background image

1.0

 Introduction 

4

2.0

 Features 

4

3.0

 Specifications 

5

4.0

 Dimensions 

6

5.0

 Mounting a pump to the system 

8

6.0

 Mounting the skid system to wall

8

7.0

 Component Identification and Typical Operation - Simplex Skid 

9

®

7.1 How to Operate the Chem-Feed  Skid System - Simplex Skid 

10

8.0

 Component Identification and Typical Operation - Duplex Skid 

11

8.1 How to operate the Chem-Feed Skid System - Duplex Skid 

12

9.0

®

 Chem-Feed  Skid System Matrix

13

10.0

 Warranty

15

Page 2

Page 3

®

CHEM-FEED  CFWS

®

CHEM-FEED  CFWS

READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE.

+1 (714) 893 - 8529

[email protected]

[email protected]

5300 Business Drive
Huntington Beach, CA 92649

Содержание CHEM-FEED CFWS Series

Страница 1: ...Municipal Skid Systems Series CFWS CHEM FEED ...

Страница 2: ... to wall 8 7 0 Component Identification and Typical Operation Simplex Skid 9 7 1 How to Operate the Chem Feed Skid System Simplex Skid 10 8 0 Component Identification and Typical Operation Duplex Skid 11 8 1 How to operate the Chem Feed Skid System Duplex Skid 12 9 0 Chem Feed Skid System Matrix 13 10 0 Warranty 15 Page 2 CHEM FEED CFWS ...

Страница 3: ...Page 3 CHEM FEED CFWS READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE 1 714 893 8529 sales blue white com customerservice blue white com 5300 Business Drive Huntington Beach CA 92649 ...

Страница 4: ...ilt and tested system includes the following standard components Pressure Relief Valve Protects the system from over pressurization 5 150 psi setting range 150 psi maximum system pressure Ships on all systems Check Valve Protects the user from back flow during pump maintenance Ships on all systems Flow Verification Sensor MS6 accurately verifies chemical feed Exclusive to Blue White Inlet Y Strain...

Страница 5: ...Page 5 CHEM FEED CFWS 3 0 Specifications Items listed below are standard available items and ship with most configurations Your system may be custom ized with components not listed below ...

Страница 6: ... Pump System 4 0 Dimensions Your Chem Feed System may be designed differently from drawings below However the dimensions shown below remain the same no matter your configuration Page 6 CHEM FEED CFWS A C D E B ...

Страница 7: ...Duplex Pump System Page 7 CHEM FEED CFWS A D F G E B C ...

Страница 8: ...and 10 32 nut Qty 4 of each per pump 6 0 Mounting the Chem Feed System 1 Locate mounting position of skid on wall 2 Use dimensions and strut to mark best location for wall anchors 3 Remove strut from skid and mount to wall with anchors 4 Re mount skid to strut 5 Mount pump s Mounting Bracket Qty 2 per pump ...

Страница 9: ...preset at 50psi Chemical Output Pressure Gauge Chemical Feed Flowmeter optional One way Check Valve with union Calibration Cylinder Pulse Dampener optional Chemical Input Y Strainer PRV Gauge Guard Page 9 CHEM FEED CFWS V1 V8 V7 V5 V4 V3 V2 V6 Pressure Switch optional Back Pressure Valve optional ...

Страница 10: ...eration Stop pump once calibration cylinder is filled Close ball valves V 1 and V 7 Open ball valve V 2 and V 8 to inject chemical solution into your system Note the chemical solution level in the calibration cylinder To calibrate pump at maximum speed into your system Press the prime button on pump The prime mode runs the pump at maximum speed for 60 seconds 1 minute on all Blue White pumps To ca...

Страница 11: ...m One way Check Valves with union PRV PRV Pressure Relief Valve preset at 50psi Chemical Output Chemical Input Chemical Feed Flowmeter Calibration Cylinder Pressure Gauge Pulsation Dampener optional Y Strainer Page 11 CHEM FEED CFWS V12 V3 V4 V5 V6 V11 V10 V9 V8 V7 V2 V1 V13 ...

Страница 12: ...nder is filled to top calibration line Do not leave pump unattended during this operation Stop pump once calibration cylinder is filled Close ball valves V 1 and V 12 Open ball valve V 2 and V 13 to inject chemical solution into your system Note the chemical solution level in the calibration cylinder To calibrate pump at maximum speed into your system Press the prime button on pump The prime mode ...

Страница 13: ...C R 8 GPH 250 ml Glass E 8 GPH 250 ml PVC S 3 GPH 100 ml Glass Pulsation Dampener P 10 cubic in X Not Included Back Pressure Valve B Included X Not Included Pressure Gauge w Guard A 200 PSI B 100 PSI C 30 PSI Pressure Switch w Guard S Included X Not Included Flow Meter w Strainer A 10 5000 mL min B 100 10000 mL min X Not Included CFWS 1 M A A V A A P B A S A X X Sample Model Number Model Number Ma...

Страница 14: ...s D 16 GPH 500 ml PVC R 8 GPH 250 ml Glass E 8 GPH 250 ml PVC S 3 GPH 100 ml Glass Pulsation Dampener P 10 cubic in X Not Included Back Pressure Valve B Included X Not Included Pressure Gauge w Guard A 200 PSI B 100 PSI C 30 PSI Pressure Switch w Guard S Included X Not Included Flow Meter w Strainer A 10 5000 mL min B 100 10000 mL min X Not Included CFWS 2 M A A V A A P B A S A X X Sample Model Nu...

Страница 15: ...rmation Purchasers installers and operators of Blue White products should take the time to inform themselves about the safe operation of these products In addition Customers are expected to do their own due diligence regarding which products and materials are best suited for their intended applications Blue White is pleased to assist in this effort but does not guarantee the suitability of any par...

Страница 16: ...l waste but use the collection framework available to them for the return recycle recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances The WEEE marking applies only to countries within the European Union EU and Norway Appliances are labeled in accordance with European Directive 2002 96 EC Contact your local waste...

Отзывы: