Blue-White industries flexflo A-100NV Скачать руководство пользователя страница 5

4.0

How To Install the A-100NV

Note: 

 All diagrams are strictly for guideline purposes only.  Always consult an expert before installing 

the A-100NV into specialized systems.
The A-100NV should be 

serviced by qualified persons only.

4.1

Mounting Location

Choose an area located near the chemical supply tank, chemical injection point and electrical supply.  
Although the pump is designed to withstand outdoor conditions, a cool, dry, well ventilated location is 
recommended.  Install the pump where it can be easily serviced.

!

Mount the pump to a  secure surface or wall using the enclosed hardware.  Wall mount to a solid surface 
only.  Mounting to drywall with anchors is not recommended.

!

Keep the outlet (discharge) tubing as short as possible.  Longer tubing increases the back pressure at the 
pump tube.

!

Do not mount the pump directly over your chemical container.  Chemical fumes may damage the unit.  
Mount the pump off to the side or at a lower level than the chemical container.

!

Mounting the pump lower than the chemical container will gravity feed the chemical into the pump. This 
“flooded suction” installation can reduce the  time required to prime the pump.  Install a shut-off valve, 
pinch clamp or other means to halt the gravity feed to the pump during servicing.

!

Your solution tank should be sturdy.  Keep the tank covered to reduce fumes.

!

Be sure your installation does not constitute a cross connection with the drinking water supply. Check 
your local plumbing codes.

A-100N

A-100N

FIG. 4.0 INJECTOR MOUNTING

FIG. 4.1 SWIMMING POOL INSTALLATION

FIG. 4.2 TYPICAL INSTALLATION

1

1

P

oo

l

2

2

3

3

5

5

4

4

6

6

7

7

8

8

9

9

10

10

1. Strainer

7. Injector

®

2. Circulation Pump

Blue-White  A-100N

3. Filter

8. Solution Tank

4. Heater

9. Injection Fitting

5. Check Valve

10. Return Line

6. Flowmeter

®

Blue-White  F-300

Discharge 

Tube

Pumping unit

R

Suction 

Tube

Chemical 
Container

¼" & ½" NPT Injector

Page 4

Page 5

Floor Mount

7-3/8”

7-5/8”

3-1/2”

8-3/16”

Drill .156 Dia. (5/32)

For Self-Tap Screw

#10 X 1” Phillips Steel

4 Places

Drill .156 Dia. (5/32)

For Self-Tap Screw

#10 X 1” Phillips Steel

2 Places

Note:  

For wall-mounting, recommend drill & thread into

           solid wood only.

Wall Mount

RUN

STANDBY

RUN

FIELD

DIGIT

MODE

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

INPUT MODES

1 - MANUAL

2 - 4-20mA

3 - 0-10VDC

4 - PULSE (Hz)

PROGRAM

RESET SERVICE

PRIME

DISPLAY

VARIABLE SPEED PUMP

% SPEED

1

MODE

VDC

SERVICE

1000

ALARM

mA

Hz

RUN

STANDBY

RUN

FIELD

DIGIT

MODE

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

INPUT MODES

1 - MANUAL

2 - 4-20mA

3 - 0-10VDC

4 - PULSE (Hz)

PROGRAM

RESET SERVICE

PRIME

DISPLAY

VARIABLE SPEED PUMP

% SPEED

1

MODE

VDC

SERVICE

1000

ALARM

mA

Hz

Содержание flexflo A-100NV

Страница 1: ...le Speed Peristaltic Injector Pump Operating Manual 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Webs...

Страница 2: ...o maintain the A 100N 16 7 1 Routine inspection and cleaning 16 7 2 How to clean and lubricate the A 100N 16 7 3 500 hour service warning timer 16 7 4 How to replace the pump tube 17 Replacement parts...

Страница 3: ...system 2 0 Specifications Maximum Working Pressure 100 psig 6 9 bar o o Maximum Fluid Temperature 130 F 54 C o o Ambient Temperature Range 14 to 110 F 10 to 43 C Duty Cycle Continuous Maximum Solids 5...

Страница 4: ...the pump tube Do not mount the pump directly over your chemical container Chemical fumes may damage the unit Mount the pump off to the side or at a lower level than the chemical container Mounting th...

Страница 5: ...umping unit R Suction Tube Chemical Container NPT Injector Page 5 RUN STANDBY RUN FIELD DIGIT MODE PROGRAM STAND BY PRIME MINIMUM MAXIMUM INPUT MODES 1 MANUAL 2 4 20mA 3 0 10VDC 4 PULSE Hz PROGRAM RES...

Страница 6: ...ections The A 100NV will accept any one of three different types of external input signals 4 20 mA 0 10 VDC or frequency Two types of frequency inputs AC sine waves magnetic coils type outputs and Dig...

Страница 7: ...WHITE frequency input JUNCTION BOX LIQUID TIGHT CONNECTOR ACCEPTABLE CABLE JACKET RANGE 118 255 INCH 3 0 6 5 MM EXTERNAL INPUT CABLE BROWN motor on contact output INPUT SIGNAL CONNECTOR 7 wire bundle...

Страница 8: ...e tube Secure the ceramic weight to the strainer Drop the strainer into the solution tank 4 3 3 Outlet Tubing Locate the outlet fitting of the Pump Tube see fig 4 6 Remove the tube nut Push the opaque...

Страница 9: ...he back pressure and interfering with the check valve operation See section 7 0 Install the Injection Check valve directly into the piping system Do not use a pipe stud with a tee for insertion of the...

Страница 10: ...pressed with the MODE button initiates the programming mode The ARROW next to the word PROGRAM will blink FIELD Button 4 In the programming mode selects the digit to be changed DIGIT Button 4 In the...

Страница 11: ...mode 2 Press the MODE button until MODE 2 is shown on the LCD display The SPEED or mA icon will light depending on the current display setting The large 3 DIGIT LCD will indicate the current motor spe...

Страница 12: ...LD button to select the digit to program The digit will blink when selected 4 Press the DIGIT button to change the selected digit 4 Repeat until all digits are programmed 4 Press the mode button Progr...

Страница 13: ...maximum VDC input signal value Press the FIELD button to select the digit to program The digit will blink when selected 4 Press the DIGIT button to change the selected digit 4 Repeat until all digits...

Страница 14: ...ut signal value Press the FIELD button to select the digit to program The digit will blink when selected 4 Press the DIGIT button to change the selected digit 4 Repeat until all digits are programmed...

Страница 15: ...in the bottom of the pump head just enough to cover the sensors and turn on the pump If the TFD system detects the chemical the pump will stop after a five second confirmation period and the ALARM ic...

Страница 16: ...may require grease periodically Apply a small amount of grease Aeroshell aviation grease 5 or equivalent when necessary Silicone oil ONLY may be used on the roller assembly and tube assembly The inje...

Страница 17: ...on side of the Pump Tube fitting into the lower retaining slot in the pump head Fig 7 2 6 4 2 2 Carefully guide the Pump Tube into the pump head Stretch the tube slightly and insert the outlet dischar...

Страница 18: ...0 15 16 11 3 14 13 31 30 17 26 27 3 2 1 2 9 52 54 5 4 7 8 56 55 10 12 28 29 25 24 23 22 21 33 32 34 F IE L D 6 53 D IG IT M O D E ST AN DB Y PR IM E R ES ET 99 SE C C YC LE TU BE LIF E WA RIN G TIM ER...

Страница 19: ...8 Star 1 25 90010 222 Wire Motor ground Digital Timers Green 1 26 A 008 1 Gearbox 14 Rpm 1 A 008 2 Gearbox 30 Rpm 1 A 008 3 Gearbox 45 Rpm 1 A 008 4 Gearbox 60 Rpm 1 A 008 5 Gearbox 125 Rpm 1 27 76001...

Страница 20: ...a brief description of the problem as well as the original invoice or sales receipt showing the date of purchase The receipt will be returned with the unit Prepay all shipping costs COD shipments will...

Отзывы: