LIMITED WARRANTY

Your new pump is a quality product and is warranted to be free of defects as set down in this policy.  All parts, including rubberized goods, and labor 
are covered under warranty for 90 days from the date of purchase.  Used peristaltic pump tube assemblies are not warranted.  Parts, excluding 
rubberized goods, are covered under warranty for 12 months from the date of purchase.  
Warranty coverage does not include damage to the pump that results from misuse, carelessness, abuse or alteration.  Only the repair or the 
replacement of the pump is covered.  Blue-White Industries does not assume responsibility for any other loss or damage.
Warranty status is determined by the pump’s serial label and the sales invoice or receipt.  The serial label must be on the pump and the pump must be 
accompanied by the sales invoice or receipt to obtain warranty coverage.  The warranty status of the pump will be verified by Blue-White or a factory 
authorized service center.

Please be advised; injection and metering devices are not intended as a means of treating water to render it suitable for human consumption.  When 
used as hypochlorinators, they are meant to destroy bacteria and algae contamination, before it’s removal by filtration.  Acid and soda injectors are 
used for PH control (balance).  Blue-White injectors are factory tested with water only for pressure and performance.  

Installers and operators of 

these devices must be well informed and aware of the precautions to be taken when injecting various chemicals -especially those considered 
hazardous or dangerous.

Should it become necessary to return an injector for repair or service, you must attach information regarding the chemical used as some residue may 
be present within the unit which could be a hazard to service personnel.
Blue-White Industries will not be liable for any damage that may result by the use of chemicals with their injectors and it’s components.  Thank you.

PROCEDURE FOR IN WARRANTY REPAIR

Carefully pack the pump to be repaired, include the foot strainer and injection/check valve fitting.  Enclose a brief description of the problem as well 
as the original invoice or sales receipt showing the date of purchase.  The receipt will be returned with the unit.  Prepay all shipping costs.  COD 
shipments will not be accepted.  Warranty service must be performed by the factory or an authorized service center.  Damage caused by improper 
packaging is the responsibility of the sender. 

AUTHORIZED SERVICE CENTERS

ARKANSAS

FLORIDA

MARYLAND

BT Environmental, Inc

AAA Electric Motor Services

Century Pool Service, Inc

Bill Thomason

1131 N.E. 45th Street

5020 Nicholson Court, #201

225 Castleberry Street

Ft. Lauderdale, FL 33334

Kensington, MD 20895

Hot Springs, AR 71901

305-772-7501

301-231-8999

501-624-3837

All American Pool & Patio

NEVADA

CALIFORNIA (NORTHERN)

2021 Curry Ford Road

Swim-In Enterprises, Inc.

Orlando, FL 32806

Howard E. Hutching company

1314 S. Main Street

407-898-8722

(Repair Center)

Las Vegas, NV 89104

7190 Penryn Plaza

Rice Pump & Motor Repair

702-384-4223

Penryn, CA 95663

5740 N.W. 9 ave.
Ft. Lauderdale FL 33309

NEW YORK

Pool-Tech, Inc.

954-776-6049

Sherwood Specialties, Inc.

401 Sunset Dr., Suite A.

412 Smith Street

Antioch, CA 94509

American Pump

Rochester, NY 14608

925-754-2424

7580-A W. Tennessee St.

716-546-1211

Tallahassee, FL 32304

Swimco Electric Co.

850-575-9618

753 Camden Avenue

NORTH CAROLINA

Campbell, CA 95008

Jerry Lee Chemical Co.

Southern Industrial Sales 

408-378-2607

3407 W. Old Fairfield Drive

1903 Herring Avenue

Pensacola, FL 32505

Wilson, NC 27893

CALIFORNIA (SOUTHERN)

904-432-9929

919-237-2500

Blue-White Industries

Picard Chemical

(Repair Center)

1670 S. Congress Avenue

SOUTH DAKOTA

5422 Business Drive

W. Palm Beach, FL 33406

Son-Aqua Distributing

Huntington Bch. CA 92649

407-965-3434

Jim Robinson

714-893-8529

2447 W. Main Street

V.J. Mini & Son, Inc.

Rapid City, SD 57702

COLORADO

1581 N. Dixie Highway

605-343-7716

Denver Winpump

Pompano Beach, FL 33060

4845 Pontiac Street

305-946-0920

TENNESSEE

Commerce City, CO 80022

Rock City Machine

303-287-2884

ILLINOIS

307 3rd Avenue South

CONNECTICUT

Nashville, TN 37201

Mullarkey Associates

Cronin-Cook  & Associates

615-244-1371

(Repair Center)

24 West Road

12346 S. Keeler Ave.

Vernon, CT 06066

TEXAS

Alsip, IL 60658

203-875-0544

Alamo Water Refiners

708-597-5558

13700 Hwy. 90 West
San Antonio, TX 78245
512-677-8400

# 80000-381

Rev.   7/18/2003

Содержание flexflo A-100NV

Страница 1: ...le Speed Peristaltic Injector Pump Operating Manual 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Webs...

Страница 2: ...o maintain the A 100N 16 7 1 Routine inspection and cleaning 16 7 2 How to clean and lubricate the A 100N 16 7 3 500 hour service warning timer 16 7 4 How to replace the pump tube 17 Replacement parts...

Страница 3: ...system 2 0 Specifications Maximum Working Pressure 100 psig 6 9 bar o o Maximum Fluid Temperature 130 F 54 C o o Ambient Temperature Range 14 to 110 F 10 to 43 C Duty Cycle Continuous Maximum Solids 5...

Страница 4: ...the pump tube Do not mount the pump directly over your chemical container Chemical fumes may damage the unit Mount the pump off to the side or at a lower level than the chemical container Mounting th...

Страница 5: ...umping unit R Suction Tube Chemical Container NPT Injector Page 5 RUN STANDBY RUN FIELD DIGIT MODE PROGRAM STAND BY PRIME MINIMUM MAXIMUM INPUT MODES 1 MANUAL 2 4 20mA 3 0 10VDC 4 PULSE Hz PROGRAM RES...

Страница 6: ...ections The A 100NV will accept any one of three different types of external input signals 4 20 mA 0 10 VDC or frequency Two types of frequency inputs AC sine waves magnetic coils type outputs and Dig...

Страница 7: ...WHITE frequency input JUNCTION BOX LIQUID TIGHT CONNECTOR ACCEPTABLE CABLE JACKET RANGE 118 255 INCH 3 0 6 5 MM EXTERNAL INPUT CABLE BROWN motor on contact output INPUT SIGNAL CONNECTOR 7 wire bundle...

Страница 8: ...e tube Secure the ceramic weight to the strainer Drop the strainer into the solution tank 4 3 3 Outlet Tubing Locate the outlet fitting of the Pump Tube see fig 4 6 Remove the tube nut Push the opaque...

Страница 9: ...he back pressure and interfering with the check valve operation See section 7 0 Install the Injection Check valve directly into the piping system Do not use a pipe stud with a tee for insertion of the...

Страница 10: ...pressed with the MODE button initiates the programming mode The ARROW next to the word PROGRAM will blink FIELD Button 4 In the programming mode selects the digit to be changed DIGIT Button 4 In the...

Страница 11: ...mode 2 Press the MODE button until MODE 2 is shown on the LCD display The SPEED or mA icon will light depending on the current display setting The large 3 DIGIT LCD will indicate the current motor spe...

Страница 12: ...LD button to select the digit to program The digit will blink when selected 4 Press the DIGIT button to change the selected digit 4 Repeat until all digits are programmed 4 Press the mode button Progr...

Страница 13: ...maximum VDC input signal value Press the FIELD button to select the digit to program The digit will blink when selected 4 Press the DIGIT button to change the selected digit 4 Repeat until all digits...

Страница 14: ...ut signal value Press the FIELD button to select the digit to program The digit will blink when selected 4 Press the DIGIT button to change the selected digit 4 Repeat until all digits are programmed...

Страница 15: ...in the bottom of the pump head just enough to cover the sensors and turn on the pump If the TFD system detects the chemical the pump will stop after a five second confirmation period and the ALARM ic...

Страница 16: ...may require grease periodically Apply a small amount of grease Aeroshell aviation grease 5 or equivalent when necessary Silicone oil ONLY may be used on the roller assembly and tube assembly The inje...

Страница 17: ...on side of the Pump Tube fitting into the lower retaining slot in the pump head Fig 7 2 6 4 2 2 Carefully guide the Pump Tube into the pump head Stretch the tube slightly and insert the outlet dischar...

Страница 18: ...0 15 16 11 3 14 13 31 30 17 26 27 3 2 1 2 9 52 54 5 4 7 8 56 55 10 12 28 29 25 24 23 22 21 33 32 34 F IE L D 6 53 D IG IT M O D E ST AN DB Y PR IM E R ES ET 99 SE C C YC LE TU BE LIF E WA RIN G TIM ER...

Страница 19: ...8 Star 1 25 90010 222 Wire Motor ground Digital Timers Green 1 26 A 008 1 Gearbox 14 Rpm 1 A 008 2 Gearbox 30 Rpm 1 A 008 3 Gearbox 45 Rpm 1 A 008 4 Gearbox 60 Rpm 1 A 008 5 Gearbox 125 Rpm 1 27 76001...