A-100N
Page 13
4
Press the mode button. The
Ma
icon will stop blinking and the
% SPEED
icon
will blink. The
ARROW
next to the word
MAXIMUM
will blink indicating the
maximum value is ready to be programmed. The currently programmed
maximum motor speed value is shown on the
3-DIGIT LCD
.
4
Enter the motor speed at the maximum mA input signal value.
Press the
FIELD button to select the digit to program. The digit will blink when
selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. The
% SPEED
icon will stop blinking and the
mA
icon
will blink indicating the maximum mA value is ready to be programmed. The
currently programmed maximum value is shown on the
3-DIGIT LCD
.
4
Enter the maximum mA input signal value.
Note: this value must be greater
than the minimum mA input signal value. Press the FIELD button to select the
digit to program. The digit will blink when selected..
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. Programming is complete.
4
To exit the programming mode, press the RUN/STANDBY button and the
MODE button at the same time. The
PROGRAM
arrow will disappear.
PROGRAM MODE 2
% speed at the maximum input
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
% SPEED
2
MODE
100
PROGRAM MODE 2
maximum input value
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
2
MODE
20.0
mA
Example 1
6
4
8 10 12 14 16 18 20
0
25
50
75
100
P
u
m
p
M
o
to
r
S
p
e
e
d
(
%
)
Milliamp input (mA)
4 mA = 0% OUTPUT
20 mA = 100% OUTPUT
Example 2
6
4
8 10 12 14 16 18 20
0
25
50
75
100
P
u
m
p
M
o
to
r
S
p
e
e
d
(
%
)
Milliamp input (mA)
4 mA = 100% OUTPUT
20 mA = 0% OUTPUT
Example 3
6
4
8 10 12 14 16 18 20
0
25
50
75
100
P
u
m
p
M
o
to
r
S
p
e
e
d
(
%
)
Milliamp input (mA)
4 mA = 0% OUTPUT
20 mA = 75% OUTPUT
Example 4
6
4
8 10 12 14 16 18 20
0
25
50
75
100
P
u
m
p
M
o
to
r
S
p
e
e
d
(
%
)
Milliamp input (mA)
4 mA = 20% OUTPUT
20 mA = 50% OUTPUT
MODE 2 PROGRAMMING EXAMPLES
5.4
-
OPERATING MODE 3 - Output adjusted by 0-10VDC input signal
In this mode, the pump’s motor speed is adjusted automatically based on the value
of the 0-10VDC input signal. Any motor speed can be assigned to either the
minimum or maximum DC input signal values. However,
the programmed
minimum VDC value must be less than the programmed maximum VDC
value.
The
ALARM
and
SERVICE
icons will blink if the programming is in
error. To assign the minimum and maximum motor speed and the minimum and
maximum VDC input signal values:
4
Set the pump for mode 3
. Press the MODE button until
MODE 3
is shown on
the LCD display. The
% SPEED
or
VDC
icon will light depending on the
current display setting. The large
3-DIGIT LCD
will indicate the current
motor speed or the VDC input value.
4
Enter the programming mode.
At the same time, press the RUN/STANDBY
and MODE buttons. A blinking
ARROW
will point to the word
PROGRAM
indicating the program mode is activated. A blinking
ARROW
will point to the
word
MINIMUM
indicating the minimum value is ready to be programmed.
The
% SPEED
icon will blink indicating the percentage of speed is ready to
be programmed.
4
Enter the motor speed at the minimum VDC input signal value.
Press the
FIELD button to select the digit to program. The digit will blink when
selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. The
% SPEED
icon will stop blinking and the
VDC
icon will blink indicating the minimum VDC value is ready to be pro-
grammed. The currently programmed minimum value is shown on the
3-
DIGIT LCD
.
4
Enter the minimum VDC input signal value.
Note: this value must be less
than the maximum VDC input signal value. Press the FIELD button to select
the digit to program. The digit will blink when selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. The
VDC
icon will stop blinking and the
% SPEED
icon will blink. The
ARROW
next to the word
MAXIMUM
will blink indicating
the maximum value is ready to be programmed. The currently programmed
maximum motor speed value is shown on the
3-DIGIT LCD
.
4
Enter the motor speed at the maximum VDC input signal value.
Press the
FIELD button to select the digit to program. The digit will blink when
selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. The
% SPEED
icon will stop blinking and the
VDC
icon will blink indicating the maximum VDC value is ready to be pro-
grammed. The currently programmed maximum value is shown on the
3-
DIGIT LCD
.
4
Enter the maximum VDC input signal value.
Note: this value must be greater
than the minimum VDC input signal value. Press the FIELD button to select
the digit to program. The digit will blink when selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. Programming is complete.
4
To exit the programming mode, press the RUN/STANDBY button and the
MODE button at the same time. The
PROGRAM
arrow will disappear.
A-100N
Page 12
PROGRAM MODE 3
% speed at the minimum input
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
% SPEED
3
MODE
000
RUN MODE 3
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
3
MODE
00.0
VDC
PROGRAM MODE 3
minimum input value
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
3
MODE
00.0
VDC
PROGRAM MODE 3
% speed at the maximum input
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
% SPEED
3
MODE
100
PROGRAM MODE 3
maximum input value
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
3
MODE
10.0
VDC