TABLE OF CONTENTS
Section
Heading
Page
1.0
Features
3
2.0
Applications
3
3.0
Specifications
3
3.1
Physical
3
3.2
Dimensional Drawing
4
3.3
Temperature vs. Pressure Graph
4
4.0
Flow ranges
5
5.0
Mounting Options
6
6.0
Electrical Wiring Connections
8
6.1
Enclosure Knock-Out Instructions
8
6.2
Optional Circuit Board Installation
8
6.3
Model RT Circuit Board Wiring
9
6.4
Model FHXX and FCXX Sensor Wiring
10
7.0
Operation
11
7.1
Theory of operation
11
7.2
Model RT Operation
11
7.2.1
Model RT Applications
11
7.2.2
Model RT Features
12
7.2.3
How to Determine Calibration Constants
12
7.2.4
Programming the Model RT
15
7.2.5
Calibration Constants
16
7.3
Programming flow chart
18
8.0
Maintenance
19
8.1
Troubleshooting
19
F-2000 parts list
20
. . .
F-2000 exploded view
21
F-2000
F-2000
Page 2
Page 3
1.0
FEATURES
2.0
APPLICATIONS
3.0
SPECIFICATIONS
3.1
Physical
Maximum Working Pressure ...... ............300 psig (20.7 bar)
o
o
Maximum fluid temperature........ ............200 F (93 C) - saddle and sensor only
o
o
200 F (93 C) - polypropylene and PVDF inline units
o
o
140 F (60 C) - molded PVC tee units
o
o
140 F (60 C) - when mounted on PVC pipe
o
o
o
o
Ambient temperature range........ ............32 F (0 C) to 110 F (43 C)
Enclosure ......... ............ ............ ............NEMA 4X (acceptable for outdoor use)
Sensor Accuracy ........... ............ ............±1% of full scale reading
Repeatability..... ............ ............ ............±1% of full scale reading
Power requirements ...... ............ ............15 VDC Nominal (16 - 24 VDC Absolute)
Model RT units only....... ............Four standard AA alkaline batteries or 16-24VDC Plug in transformer
(Battery life expectancy 1 year minimum)
All units ............ ............ ............16-24VDC (plug-in transformer supplied)
Model AO analog output board... ............Linear, Non-isolated, powered loop. 250 ohm max for 4-20 ma / 500
ohms minimum for 0-10 VDC
Model PC Process control board ............Relay SPDT, NO/NC
Maximum switching load
8 amps @ 115 VAC, 220 VAC, 230 VAC
7 amps @ 30 VDC (resistive load)
Maximum fluid debris size .......... ............0.020” diameter
Model RT
!
Measure and display the rate of flow
!
Measure and display the total flow
Model AO
!
Measure and display the rate of flow
!
Measure and display the total flow
!
Control external devices with 4-20mA
control signal
!
Control external devices with 0-10VDC
control signal
Model PC
!
Measure and display the rate of flow
!
Measure and display the total flow
!
Maintain a flow rate range alarm
!
Trigger a high flow rate alarm
!
Trigger a low flow rate alarm
!
Manually controlled batch processing
!
Timed auto-reset batch processing
!
Proportional flow chemical pump process
control
!
!
Battery powered rate and total
Weather resistant enclosure (NEMA 4X)
!
!
Extended battery life mode
Corrosion resistant PVDF sensor
(screen blanks after 30 seconds)
!
Corrosion resistant ABS enclosure
!
Easy to read, eight digit LCD display
!
High accuracy
!
Installs quickly on existing pipe
!
Extended flow range
!
Factory programmed
!
Front panel security lockout
!
Field programmable front panel push buttons
!
Minimal maintenance required
!
No pressure drop