C3

5.4

 

FVS - Flow Verification System

 

The C3 is equipped with a 

Flow Verification System

 which is designed to stop 

the pump and provide a contact closure output in the event the sensor does not 
detect flow during pump operation. This could indicate a clogged injection fitting, 
empty chemical solution tank, loose tubing connection, etc.
To allow the pump to clear any gasses that may have accumulated during 
stopper operation (such as with chlorine), an alarm delay time value from 1-255 
seconds must be programmed (An alarm delay value of 000 seconds disables 
the FVS system).

 

- (sensor sold separately)

Install the FVS Flow Sensor - 

The Flow Verification Sensor (FVS) should be 

installed on the outlet (discharge) side of the pump head valve.
Connect the red/white, black, and white wires from the sensor to the red, black, 
and yellow wires located in the pump’s junction box. 

300-3000

FV-400-1V

500-5000

FV-500-1V

700-7000

FV-600-1V

Sensor

Model

Number

Operating Flow Range

mL/min

4.8-47.5

7.9-79.3

11.1-111

GPH (US)

Contact Closure Alarm Output - 

A contact closure output (relay) is provided 

with the FVS system. The relay can be configured for normally open (factory 
default) or normally closed operation by properly positioning the connector plug 
on the circuit board . 

Adapter

½” barb
½” barb
½” barb

Maximum
PSI / BAR

150 / 10.3
150 / 10.3
150 / 10.3

300-3000

300-3000

FV-400-2V

500-5000

500-5000

FV-500-2V

700-7000

700-7000

FV-600-2V

FV-400-3V
FV-500-3V
FV-600-3V

4.8-47.5

4.8-47.5

7.9-79.3

7.9-79.3

11.1-111

11.1-111

½” M/NPT
½” M/NPT

½” M/NPT

½” F/NPT

½” F/NPT

½” F/NPT

150 / 10.3
150 / 10.3

150 / 10.3

150 / 10.3

150 / 10.3

150 / 10.3

C3V  |  Diaphragm Metering Pump

Made in the USA

MODE

PRIME

Program

Minimum

Maximum

Blue-White Ind.

IP66

NEMA 4X

FVS

Sensor

SIGNAL INPUT/OUTPUT  WIRE COLOR CODES

WIRE COLOR CODE

INPUT TYPE

FLOW VERIFICATION SENSOR (FVS)

ALARM RELAY

connect 2-conductor plug to either

normally open (NO) (factory default)

or normally closed (NC) side of receptacle. 

3 AMP MAX @ 125VAC (24VDC)

PURPLE

 & 

PURPLE

RED/WHITE (+ 

20VDC)

BLACK (-)

YELLOW 

(signal)

6.0  C3F External Input / Output Signal Connection

Содержание CHEM-PRO ProSeries C3 Series

Страница 1: ...ve Displacement Diaphragm Metering Pump C3 Series Industries Ltd ProSeries by Blue White Ind TM www Blue White com by Blue White Industries CHEM PRODiaphragm Metering Pumps i n DF Bu lt I D ph a m Fa...

Страница 2: ...7 5 4 Flow Verification System 8 6 C3F External Input Output Signal Connection 9 6 1 How to operate the C3F 10 7 C3V External Input Output Signal connection 11 7 1 How to operate the C3V 12 7 2 Operat...

Страница 3: ...he C3 Diaphragm Metering Pump The C3 is designed to inject chemicals into piping systems and is capable of injecting against a high system pressure up to 175 PSI 12 1 bar C3 Depending on model selecti...

Страница 4: ...on with the drinking water supply Check your local plumbing codes CAUTION Always wear protective clothing face shield safety glasses and gloves when working on or near your metering pump Additional pr...

Страница 5: ...stable mounting surface Blue White s Stainless Steel extended brackets allow the pump to be securely mounted to most any surface floor shelf or skid The brackets lift the pump up 4 1 2 inches 11 43 c...

Страница 6: ...r Discharge Pipe or 1 2 Tubing not included Injection Check Valve Pipe Tee Install upward for best results Injection Check Valve Fitting Installation The Injection Check valve fitting is designed to i...

Страница 7: ...gm failure can occur The DFD sensors will detect the chemical behind the diaphragm caused by diaphragm failure The pump will then shut down and energize an internal 3 amp relay You can wire the 3 amp...

Страница 8: ...d white black and white wires from the sensor to the red black and yellow wires located in the pump s junction box 300 3000 FV 400 1V 500 5000 FV 500 1V 700 7000 FV 600 1V Sensor Model Number Operatin...

Страница 9: ...E FLOW VERIFICATION SENSOR FVS ALARM RELAY connect 2 conductor plug to either normally open NO factory default or normally closed NC side of receptacle 3 AMP MAX 125VAC 24VDC PURPLE PURPLE RED WHITE 2...

Страница 10: ...g Pump NEMA 4X IP66 To start the pump press the Start Stop button To increase the output press the Up button To decrease the output press the Down button To stop the pump press the Start Stop button T...

Страница 11: ...HALL EFFECT SENSOR BLACK RED PUMP INPUT WIRE COLOR CODE MODEL FC AC SINE WAVE SENSOR BARE signal BLACK RED 20VDC WHITE signal BLACK RED BLACK WHITE 4 20 mA 0 10 VDC AC sine wave TTL CMOS 7 0 C3V Exter...

Страница 12: ...V Modes MODE 0 DFD Diaphragm Failure Detection On Off FVS Flow Verification System 0 OFF 1 255 Seconds ON Please Note You will not see the FVS icon or be able to configure the FVS unless an FVS sensor...

Страница 13: ...ill point to the word PROGRAM indicating the program mode has been activated MODE MODE Press the DOWN button to select the digit to program The digit will blink when selected Press the UP button to ch...

Страница 14: ...peed is ready to be programmed 4 Enter the motor speed at the minimum mA input signal value Press the DOWN button to select the digit to program The digit will blink when selected Press the UP button...

Страница 15: ...mA from external source 70 Output Mode 2 Programming Examples 4 Enter the maximum mA input signal value Note this value must be greater than the minimum mA input signal value Press the DOWN button to...

Страница 16: ...programming mode While MODE 3 is displayed Press and hold the MODE button for more than two seconds tm CHEM PRO C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue Whit...

Страница 17: ...VDC icon will blink indicating the maximum VDC value is ready to be pro grammed The currently programmed maximum value is shown on the LCD 4 Enter the maximum VDC input signal value Note this value m...

Страница 18: ...signal Any motor speed can be assigned to either the minimum or maximum Hz input signals 4 Set the pump for mode 4 Press the MODE button until MODE 4 is shown on the LCD display The SPEED or Hz icon...

Страница 19: ...DE Press the MODE button The Hz icon will stop blinking and the SPEED icon will blink The ARROW next to the word MAXIMUM will blink indicating the maximum value is ready to be pro grammed The Currentl...

Страница 20: ...1 0 Hz will result in a pump output of 0 0 1000 Hz will result in a pump output of 0 0 0 1000 90 Output 200 400 600 800 Example 3 0 Hz will result in a pump output of 90 0 1000 Hz will result in a pum...

Страница 21: ...UM tm CHEM PRO C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue White Ind IP66 NEMA 4X Mode 5 MODE A blinking ARROW will point to the word PROGRAM and the SPEED icon...

Страница 22: ...d MIN Press the MODE button The SEC or MIN icon will stop blinking and the Hz icon will blink indicating the number of pulses is ready to be programmed 4 Enter the number of pulses to trigger the batc...

Страница 23: ...by turning the valve to the right 5 Run the pump until all air is removed from the suction line and the solution enters the discharge tubing If the pump does not easily prime loosen the priming valve...

Страница 24: ...pump that has been caused by chemical attack 9 2How to Clean the Pump The pump will require occasional cleaning especially the Injection fitting the Footvalve Strainer and the pump head valves The fr...

Страница 25: ...Page 25 C3 PUMP HEAD AND VALVE EXPLODED VIEW...

Страница 26: ...Page 26 C3 Replacement Parts Drawing 6 12 3 14 15 13 23 24 27 30 17 29 28 25 21 21 16 18 19 20 22 5 1 8 7 10 11 26 9 2 4...

Страница 27: ...Bumper Feet 15 76001 347 Backup Washer Diaphragm 1 16 90011 115 Screw for housing 10 32x 50L SS 10 17 76000 361 Tubing Suction C3 75 OD x 50 ID x 8ft 1 18 70002 276 Motor 130RPM 1 70002 277 Motor 62R...

Страница 28: ...Page 28 C3 Intentionally left blank...

Страница 29: ...Page 29 C3 Intentionally left blank...

Страница 30: ...ions to be taken when injecting various chemicals especially those considered hazardous or dangerous Should it become necessary to return an injector for repair or service you must attach information...

Страница 31: ...NOIS Mullarkey Associates Repair Center 12346 S Keeler Ave Alsip IL 60658 708 597 5558 NEW YORK Sherwood Specialties Inc Repair Center 875 Atlantic Ave Rochester NY 14608 585 546 1211 NORTH CAROLINA S...

Страница 32: ...2006 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Website www blue white com Industries Ltd ProSeries...

Отзывы: