Page 18
Page 19
C3
C3
4
Enter the motor speed at the minimum Hz input signal value.
Press the
DOWN
button to select the digit to program. The digit will blink
when selected.
Press the
UP
button to change the selected digit.
Repeat until all digits are programmed.
Program
Minimum
Maximum
Press the
MODE
button. The
% SPEED
icon will stop
blinking and the
Hz
icon will blink indicating the
minimum Hz value is ready to be programmed. The
currently programmed minimum value is shown on
the
LCD
.
4
Enter the minimum Hz input signal value (to the nearest 10 Hz).
Note:
this value must be less than the maximum Hz input signal value.
Press the
DOWN
button to select the digit to program. The digit will blink
when selected.
Press the
UP
button to change the selected digit.
Repeat until all digits are programmed.
MODE
MODE
MODE
Press the
MODE
button. The
Hz
icon will stop
blinking and the
% SPEED
icon will blink. The
ARROW
next to the word
MAXIMUM
will blink
indicating the maximum value is ready to be pro-
grammed. The Currently programmed maximum
motor speed value is shown on the
LCD
.
4
Enter the motor speed at the maximum VDC input signal value.
Press the
DOWN
button to select the digit to program. The digit will blink
when selected.
Press the
UP
button to change the selected digit.
Repeat until all digits are programmed.
Press the
MODE
button. The
% SPEED
icon will stop blinking and the
Hz
icon will blink indicating the maximum Hz value is ready to be programmed.
The currently programmed maximum value is shown on the
LCD
.
4
Enter the maximum Hz input signal value (to the nearest 10 Hz).
Note:
this value must be greater than the minimum Hz input signal value.
Press the
DOWN
button to select the digit to program. The digit will blink
when selected.
Press the
UP
button to change the selected digit.
Program
Minimum
Maximum
Mode 3 Programming Examples, continued
0%
25%
50%
75%
100%
P
u
m
p
O
u
tp
u
t
M
o
to
r
S
p
e
e
d
VDC input
from external source
0%
Output
Example 2
0 VDC will result in a pump output of
90%
10 VDC will result in a pump output of
0.0%
0
10
90%
Output
2
4
6
8
2
4
6
0%
25%
50%
75%
100%
P
u
m
p
O
u
tp
u
t
M
o
to
r
S
p
e
e
d
VDC input
from external source
100%
Output
Example 3
0 VDC will result in a pump output of
0.0%
10 VDC will result in a pump output of
100.0%
0
8
0%
Output
10
7.5
OPERATING MODE 4 - Frequency (Hz) Mode
Also known as Pulse Input. In this mode, the pump’s motor speed is adjusted
automatically based on the frequency (Hz) of the input signal. Any motor speed
can be assigned to either the minimum or maximum Hz input signals.
4
Set the pump for mode 4
.
Press the MODE button until
MODE 4
is shown on the LCD display.
The
% SPEED
or
Hz
icon will light
depending on the current display
setting.
The large
LCD
will indicate the current
motor speed or the Hz input value.
4
Enter the programming mode.
While
MODE 4
is displayed, press and
hold the
MODE
button for more than
two seconds.
tm
CHEM-PRO
C3V | Diaphragm Metering Pump
Made in the USA
MODE
PRIME
Program
Minimum
Maximum
Blue-White Ind.
IP66
NEMA 4X
Mode 4
MODE
Blinking
ARROW’s
will point to the word
PROGRAM
and
MINIMUM
indicating the program mode is activated and the minimum value is ready to
be programmed. The
% SPEED
icon will blink indicating the percentage of
speed is ready to be programmed.
MODE
Содержание CHEM-PRO ProSeries C3 Series
Страница 25: ...Page 25 C3 PUMP HEAD AND VALVE EXPLODED VIEW...
Страница 28: ...Page 28 C3 Intentionally left blank...
Страница 29: ...Page 29 C3 Intentionally left blank...