5.2  How To Install the Tubing and Fittings

 

!

Suction (Inlet) Tubing

Locate the inlet fitting of the pump head. Push the clear suction tubing onto the 
fitting barb.

Page 6

Page 7

C3

C3

CAUTION: Proper eye and skin protection must be worn when 

installing and servicing the pump and fittings.

!

Footvalve / Strainer

Trim the inlet end of the suction tubing so 
that the strainer will rest approximately two 
inches from the bottom of the solution tank. 
This will prevent sediment from clogging the 
strainer. Press the strainer’s barbed fitting 
into the end of the tube. Drop the footvalve / 
strainer into the solution tank.

FootValve
Strainer
Assembly

Suction
(inlet)
Tubing

Footvalve / Strainer

Discharge
Pipe or
1/2” Tubing
(not included)

Injection / Check Valve

Pipe
Tee

Install

upward

for best

results

!

Injection / Check Valve Fitting Installation

The Injection / Check valve fitting is designed 
to install directly into  1/2” female pipe 
threads. This fitting will require periodic 
cleaning, especially when injecting fluids that 
calcify such as sodium hypochlorite. 
Install the Injection / Check valve directly into 
the piping system. 

To prevent trapped 

gasses, install the fitting in an upward 
direction.

 Use Teflon thread sealing tape on 

the pipe threads.

At high pressures, Blue-White recommends 
using a threaded connection. 

Injection / Check Valve is available with 1/2” 
Male NPT or 1/2” Hose Barb. This is based 
on the outlet connection selected for the C3 
pump.

Keep discharge (outlet) tube as short as 
possible.

Hose
Barb

1/2” Male
NPT

1/2” Male NPT
(optional 1/2”
Hose Barb)

5.3  DFD (Diaphragm Failure Detection)

C3F Display

C3F Display

C3V Display

C3V Display

Blue-White Industries

Made in the USA

tm

CHEM-PRO

D

iaphragm

F

ailure

D

etection

C3F  |  Diaphragm Metering Pump

NEMA 4X

IP66

tm

CHEM-PRO

C3V  |  Diaphragm Metering Pump

Made in the USA

MODE

PRIME

Program

Minimum

Maximum

Blue-White Ind.

IP66

NEMA 4X

ALARM

ALARM

ALARM

ALARM

DFD ALARM

icons

DFD ALARM

icons

DFD Sensors

Diaphragm

The C3 includes DFD sensors built directly into the pump. Although it doesn’t happen 
often, diaphragm failure can occur. The DFD sensors will detect the chemical behind 
the diaphragm caused by diaphragm failure. The pump will then shut down and 
energize an internal 3 amp relay. You can wire the 3 amp relay to an alarm, SCADA 
system, backup pump, or nothing at all.

If the DFD Alarm has been 
triggered, the diaphragm 
must be replaced and the 
pumphead must be 
thoroughly cleaned.

You can reset the DFD 
alarm by pressing the 
Start/Stop button.

If the DFD Alarm is triggered, the DFD and ALARM icons will begin 
flashing.

Note:

 The DFD system will not reset until you have removed all traces of chemical 

from behind the diaphragm.

Pumphead

Outlet

(discharge)

Inlet

(suction)

l  -

Bu

i t

I D

FD

Dia

a

 

il

phr

gm

Fa

ure

De

c

n

te

tio

Содержание CHEM-PRO ProSeries C3 Series

Страница 1: ...ve Displacement Diaphragm Metering Pump C3 Series Industries Ltd ProSeries by Blue White Ind TM www Blue White com by Blue White Industries CHEM PRODiaphragm Metering Pumps i n DF Bu lt I D ph a m Fa...

Страница 2: ...7 5 4 Flow Verification System 8 6 C3F External Input Output Signal Connection 9 6 1 How to operate the C3F 10 7 C3V External Input Output Signal connection 11 7 1 How to operate the C3V 12 7 2 Operat...

Страница 3: ...he C3 Diaphragm Metering Pump The C3 is designed to inject chemicals into piping systems and is capable of injecting against a high system pressure up to 175 PSI 12 1 bar C3 Depending on model selecti...

Страница 4: ...on with the drinking water supply Check your local plumbing codes CAUTION Always wear protective clothing face shield safety glasses and gloves when working on or near your metering pump Additional pr...

Страница 5: ...stable mounting surface Blue White s Stainless Steel extended brackets allow the pump to be securely mounted to most any surface floor shelf or skid The brackets lift the pump up 4 1 2 inches 11 43 c...

Страница 6: ...r Discharge Pipe or 1 2 Tubing not included Injection Check Valve Pipe Tee Install upward for best results Injection Check Valve Fitting Installation The Injection Check valve fitting is designed to i...

Страница 7: ...gm failure can occur The DFD sensors will detect the chemical behind the diaphragm caused by diaphragm failure The pump will then shut down and energize an internal 3 amp relay You can wire the 3 amp...

Страница 8: ...d white black and white wires from the sensor to the red black and yellow wires located in the pump s junction box 300 3000 FV 400 1V 500 5000 FV 500 1V 700 7000 FV 600 1V Sensor Model Number Operatin...

Страница 9: ...E FLOW VERIFICATION SENSOR FVS ALARM RELAY connect 2 conductor plug to either normally open NO factory default or normally closed NC side of receptacle 3 AMP MAX 125VAC 24VDC PURPLE PURPLE RED WHITE 2...

Страница 10: ...g Pump NEMA 4X IP66 To start the pump press the Start Stop button To increase the output press the Up button To decrease the output press the Down button To stop the pump press the Start Stop button T...

Страница 11: ...HALL EFFECT SENSOR BLACK RED PUMP INPUT WIRE COLOR CODE MODEL FC AC SINE WAVE SENSOR BARE signal BLACK RED 20VDC WHITE signal BLACK RED BLACK WHITE 4 20 mA 0 10 VDC AC sine wave TTL CMOS 7 0 C3V Exter...

Страница 12: ...V Modes MODE 0 DFD Diaphragm Failure Detection On Off FVS Flow Verification System 0 OFF 1 255 Seconds ON Please Note You will not see the FVS icon or be able to configure the FVS unless an FVS sensor...

Страница 13: ...ill point to the word PROGRAM indicating the program mode has been activated MODE MODE Press the DOWN button to select the digit to program The digit will blink when selected Press the UP button to ch...

Страница 14: ...peed is ready to be programmed 4 Enter the motor speed at the minimum mA input signal value Press the DOWN button to select the digit to program The digit will blink when selected Press the UP button...

Страница 15: ...mA from external source 70 Output Mode 2 Programming Examples 4 Enter the maximum mA input signal value Note this value must be greater than the minimum mA input signal value Press the DOWN button to...

Страница 16: ...programming mode While MODE 3 is displayed Press and hold the MODE button for more than two seconds tm CHEM PRO C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue Whit...

Страница 17: ...VDC icon will blink indicating the maximum VDC value is ready to be pro grammed The currently programmed maximum value is shown on the LCD 4 Enter the maximum VDC input signal value Note this value m...

Страница 18: ...signal Any motor speed can be assigned to either the minimum or maximum Hz input signals 4 Set the pump for mode 4 Press the MODE button until MODE 4 is shown on the LCD display The SPEED or Hz icon...

Страница 19: ...DE Press the MODE button The Hz icon will stop blinking and the SPEED icon will blink The ARROW next to the word MAXIMUM will blink indicating the maximum value is ready to be pro grammed The Currentl...

Страница 20: ...1 0 Hz will result in a pump output of 0 0 1000 Hz will result in a pump output of 0 0 0 1000 90 Output 200 400 600 800 Example 3 0 Hz will result in a pump output of 90 0 1000 Hz will result in a pum...

Страница 21: ...UM tm CHEM PRO C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue White Ind IP66 NEMA 4X Mode 5 MODE A blinking ARROW will point to the word PROGRAM and the SPEED icon...

Страница 22: ...d MIN Press the MODE button The SEC or MIN icon will stop blinking and the Hz icon will blink indicating the number of pulses is ready to be programmed 4 Enter the number of pulses to trigger the batc...

Страница 23: ...by turning the valve to the right 5 Run the pump until all air is removed from the suction line and the solution enters the discharge tubing If the pump does not easily prime loosen the priming valve...

Страница 24: ...pump that has been caused by chemical attack 9 2How to Clean the Pump The pump will require occasional cleaning especially the Injection fitting the Footvalve Strainer and the pump head valves The fr...

Страница 25: ...Page 25 C3 PUMP HEAD AND VALVE EXPLODED VIEW...

Страница 26: ...Page 26 C3 Replacement Parts Drawing 6 12 3 14 15 13 23 24 27 30 17 29 28 25 21 21 16 18 19 20 22 5 1 8 7 10 11 26 9 2 4...

Страница 27: ...Bumper Feet 15 76001 347 Backup Washer Diaphragm 1 16 90011 115 Screw for housing 10 32x 50L SS 10 17 76000 361 Tubing Suction C3 75 OD x 50 ID x 8ft 1 18 70002 276 Motor 130RPM 1 70002 277 Motor 62R...

Страница 28: ...Page 28 C3 Intentionally left blank...

Страница 29: ...Page 29 C3 Intentionally left blank...

Страница 30: ...ions to be taken when injecting various chemicals especially those considered hazardous or dangerous Should it become necessary to return an injector for repair or service you must attach information...

Страница 31: ...NOIS Mullarkey Associates Repair Center 12346 S Keeler Ave Alsip IL 60658 708 597 5558 NEW YORK Sherwood Specialties Inc Repair Center 875 Atlantic Ave Rochester NY 14608 585 546 1211 NORTH CAROLINA S...

Страница 32: ...2006 5300 Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com or techsupport blue white com Website www blue white com Industries Ltd ProSeries...

Отзывы: