We recommend putting the filter system on a concrete slab or similar. Be sure the
installation is level.

Additional installation accessories such as hoses, hoses clamps, and filter sand
(not included) are available from your pool dealer.

K

.

Filter-Pump Assembly (Figure 1)

1. Filter pump & Base Plate assembly

Secure filter pump to the base plate with the provided pump mounting hardware.
Orient as shown.

2. The filter pump consists of the following components:

a. Pump body
b. 7 position valve

c. Internal Seal (O-Ring) seal

d. Valve plate clamping ring with bolt & nut

f. Riser pipe w connecting

ith

hub for filter laterals

e. Filter tank

g. Filter laterals

h. Drain plug assembly

i. Centering plate & Sand guard
j. Base plate

k. Pressure hose or Pre-assembled PVC pipe

3.

Filter Tank assembly

a. The riser pipe with connecting hub for filter laterals is inserted into the tank

(Figure 2). Screw the filter laterals into the connecting hub. (Figure 2&3).

b. Install the tank drain assembly as shown in figure 1, key 8.
c. Make sure that the riser pipe and laterals are seated on the bottom of the tank.
d. Put the centering plate sand guard on the tank opening, while centering the riser

pipe. (Figure 4)

e. Fill the filter tank to about 1/8 depth with water then up to 3/4 full with #20 Pool Filter 

Grade silica sand.

NOTE: Installation of sand other than #20 Pool Filter Grade silica sand will NOT 

function properly, and may void your warranty. 

Cotton Tails filter media can be substituted for #20 Pool Filter Grade silica sand.

f. Attach the 7 position valve to the Tank opening using the thick O-ring and the

clamping ring (Figure 1, 5&6). Before you do this, clean tank opening to wash off
any sand or accumulated debris. The clamping ring is connected with the clamping
ring bolt and nut (Figures 5 & 6).

g. The pressure gauge (if included) is screwed to the side of the 7 position valve

.

Seal with Teflon tape. The pre-installed vent plug must be removed first (Figure 9).

h. Attach the pump fittings to the 7 position valve. Seal the pump fittings sufficiently

with Teflon tape.

4.

Pump Hose Connections (Figure 7)

a. Skimmers: Connect hose from pool skimmer to the intake fitting on the filter pump.
b. Pressure line: Connect the flexible corrugated hose from the upper discharge point

on the top of the filter pump to the connector with designation “PUMP” on the 7-way
valve. Use stainless steel hose clamps to secure both ends of the hose.

c. Return line: Connect flexible hose or hard PVC pipe from the 7-way valve port with

the designation “RETURN” to the connection for the pool skimmer. Secure all

Page 05

Содержание FlowXtreme Pro NE4490

Страница 1: ...VER 0418 NE4490 NE4499 FlowXtreme Pro Filter System Manual...

Страница 2: ...before operating Never change the 7 Position Multi Port Valve while the system is operating ALWAYS unplug the system before changing the control valve Install this product with sufficient safety marg...

Страница 3: ...ct information contained in this technical manual If there is any indication that safe operation is no longer possible the device is to be disconnected from the power supply and secured against accide...

Страница 4: ...Gallons H Unpacking your filter system Carefully remove the product and all component parts from the box Cross reference all parts in the box with the parts list reference chart to make certain all p...

Страница 5: ...l the filter tank to about 1 8 depth with water then up to 3 4 full with 20 Pool Filter Grade silica sand NOTE Installation of sand other than 20 Pool Filter Grade silica sand will NOT function proper...

Страница 6: ...kwash process described below Turn off the Motor Pump at the Power Source Attach backwash hose not included to backwash port Place the Multi Port Valve in the 4 Backwash position Turn on the Pump Run...

Страница 7: ...causes the sand to separate and lift while releasing trapped debris out the waste port and backwash hose Closed Position 5 Function Cleaning the hair and lint strainer This position stops the flow of...

Страница 8: ...8 of tank height of water Cover the water chamber to avoid getting sand inside the riser pipe and laterals Start filter in Backwash mode for about 3 minutes and then for about 1 minute in the rinse m...

Страница 9: ...n Check the socket and power cord G F C I or main circuit breaker tripped Switch on the breaker if it is immediately tripped again there is a defect in pump or controls Pump motor defective Replace mo...

Страница 10: ...S Installation and Operation Illustration Figures Page 10 1 2 8 6 9 3 4 5 7 a b c d d e f g h i j k...

Страница 11: ...PIN 1 3015 NEP4072 NE4490 NE4499 16 RIGHT CLAMP 1 3016 NEP4073 NE4490 NE4499 17 LEFT CLAMP 1 3017 NEP4074 NE4490 NE4499 18 MIDDLE PIPE 1 30184 NEP4095 NE4490 18 LONG PIPE 1 30185 NEP4096 NE4499 19 DI...

Страница 12: ...P4191 All DRAIN PLUG O RING HTA008 NEP4192 All 7 O RING HTA009 NEP4193 All 8 SCREW HTA010 NEP4194 All 9 PUMP COVER HTA011 NEP4195 All 10 O RING HTA012 NEP4196 All 11 IMPELLER OF ITEM HTA 075 HTA2SP 07...