BLUE SKY Solar Boost 2512i Скачать руководство пользователя страница 4

Blue Sky Energy - Solar Boost 2512i and 2512iX 

 

PRODUCT DESCRIPTION

 

 

 

Solar Boost™™ 2512i and 2512iX are 25 amp 12 volt 

Maximum Power Point Tracking

 (MPPT) photovoltaic (PV) battery charge controllers. The full 

featured Solar Boost 2512iX includes all the features described in this manual. The Solar Boost 2512i omits certain features to reduce cost. 

 

 

Through the use of patented MPPT technology the 2512 can increase charge current up to 30% or more compared to conventional controllers. The 

2512’’s  sophisticated  three  stage  charge  control  system  improves  battery  performance  and  life  while  minimizing  battery  maintenance.  The  unit  is  fully 
protected against voltage transients, over temperature, over current, reverse battery and reverse PV connections. An automatic current limit feature allows 
use of the full 25 amp capability without worrying about overload or nuisance fuse blow from excessive current. An environmentally sealed high current high 
reliability relay is used to disconnect the PV array at night to prevent unwanted current drain. An IPN Network display interface is provided in both versions of the 
product allow use of the available IPN-Remote or IPN-ProRemote displays. 

 

 

Additional features included in the Solar Boost 2512iX version of the product include a battery temperature sensor input, equalization capability, full IPN 

Network interface, and an auxiliary output. The versatile auxiliary output can provide either a 2 amp battery charger for a second battery, 25 amp voltage or 
amp-hour based load control, or 25 amp variable Dusk-to-Dawn lighting control. The full IPN Network interface included in the Solar Boost 2512iX allows 
multiple  IPN  compatible  charge  controllers  to  communicate  with  each  other  and  operate  as  a  single  charging  machine  rather  than  separate  charge 
controllers. 

 

FEATURES OMITTED IN THE SOLAR BOOST 2512i 

 

 

The following features described in this manual are omitted in the lower cost Solar Boost 2512i version of the product. See Figure 3 for omitted connectors 

and setup selectors. 

 

x

 Battery Temperature sensor input 

x

 Battery equalization capability  

x

 Full IPN Network interface (for multi-controller coordination) 

x

 Auxiliary Output (for load & lighting control, or auxiliary battery charge) 

 

PART NUMBERS AND OPTIONS 

 

x

 SB2512i ..............Basic Solar Boost 2512i charge controller 

x

 SB2512iX ........... Full featured Solar Boost 2512iX charge controller 

x

 IPNPRO  .............IPN-ProRemote display & battery monitor 

x

 IPNPRO-S .......... IPN-ProRemote with required 500A/50mV current shunt 

x

 CS-500  ...............500A/50mV current shunt 

x

 IPNREM ............. IPN-Remote display 

x

 930-0022-20 .......Battery temperature sensor 

x

 930-0039-01 ....... Deluxe mounting box, black powder coated 

 

OPERATION 

 

Charge control and MPPT operation are fully automatic. At night when PV power production stops, the PV array is disconnected from the battery to 

prevent unwanted current drain. There is a 5 second turn-on delay, and a 45 second turn-off delay. 
 

¾

 The 2512 operates on battery power, not PV power. A battery must be connected with a minimum voltage of 9V for the unit to 

operate.  

 

 

CHARGE STATUS INDICATOR 

 

 

A charge status indicator is provided on the face of the 2512, and on the optional remote displays. If net battery charge current is greater than  

|

3 to 5 amps 

per 100 amp-hours of battery capacity the charge status indicator can provide a rough indication of battery state of charge.  

 

CHARGE STATUS INDICATOR 

 

CHARGE STATUS INDICATOR 

CHARGE MODE 

APPROXIMATE CHARGE LEVEL 

OFF 

CHARGE OFF 

 

CONTINUOUSLY ON 

BULK 

<70% FULL 

BLINKING  

x

 1 SEC ON / 1 SEC OFF 

ACCEPTANCE 

70% - 95% FULL 

BLINKING  

x

  0.2 SEC ON / 1 SEC OFF 

FLOAT 

FULLY CHARGED 

RAPID BLINKING  

x

  0.2 SEC ON / 0.2 SEC OFF 

EQUALIZE 

 

 

TABLE 1 

 

AUXILIARY OUTPUT INDICATOR 

(Omitted on SB2512i)

 

 

 

An Auxiliary Output indicator labeled ““LOAD”” is provided on the face of the SB2512iX, and is omitted on the SB2512i. The indicator will be ON when the 

auxiliary output is ON providing power to a load, or charging an auxiliary battery. Auxiliary Output status can also be viewed on the IPN-ProRemote.  

 

OPTIONAL REMOTE DISPLAYS 

 

 

There are two available remote displays, the low cost IPN-Remote and the full featured IPN-ProRemote. The IPN-Remote is a basic 3-digit LED type 

voltage,  current  and  charge  mode  display  without  setup  or  control  capability.  The  full  featured  IPN-ProRemote  provides  setup  capability  and  enhanced 
monitoring of charge controllers on the IPN network. It also provides a complete battery system monitor with various amp-hour counters and a highly accurate 
““fuel gage”” type battery level indicator.  

 
 
 
 

)

 

Содержание Solar Boost 2512i

Страница 1: ...IC CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL THIS MANUAL INCLUDES IMPORTANT SAFETY INSTRUCTIONS FOR MODELS SB2512i and SB2512iX SAVE THESE INSTRUCTIONS COVERED UNDER ONE OR MORE OF THE FOLLOWING US PATENTS 6 111 391 x 6 204 645 Blue Sky Energy Inc 2011 430 0021 E ...

Страница 2: ...LLATION 5 Electrostatic Handling Precautions 6 Selecting PV Modules 6 As Shipped Factory Default Settings 6 Equalize Enable 6 Battery Temperature Sensor 6 Battery and PV Wiring 7 Auxiliary Output 10 Auxiliary Battery Charge 8 Load Controller 8 Dusk to Dawn Lighting Control 8 Installing a Multi Controller System 8 Multi Controller Wiring And Setup 8 IPN Network Address 9 Mounting 9 TROUBLESHOOTING ...

Страница 3: ...battery can produce a short circuit current high enough to weld a ring or the like to metal causing a severe burn j Remove all sources of power photovoltaic and battery before servicing or installing 4 CHARGER LOCATION INSTALLATION a This unit is designed to charge 12V 6 cell flooded or sealed type lead acid chemistry batteries within the range of 20 to 10 000 amp hours Follow battery manufacturer...

Страница 4: ...oller coordination x Auxiliary Output for load lighting control or auxiliary battery charge PART NUMBERS AND OPTIONS x SB2512i Basic Solar Boost 2512i charge controller x SB2512iX Full featured Solar Boost 2512iX charge controller x IPNPRO IPN ProRemote display battery monitor x IPNPRO S IPN ProRemote with required 500A 50mV current shunt x CS 500 500A 50mV current shunt x IPNREM IPN Remote displa...

Страница 5: ...at charge voltage setting to No Float using the IPN ProRemote Refer to the IPN ProRemote operators manual FRONT PANEL INDICATORS FIGURE 1 EQUALIZATION Omitted on SB2512i WARNING Not all batteries can be safely equalized Equalization should be performed only on vented liquid electrolyte lead acid batteries Always follow battery manufacturers recommendations pertaining to equalization Equalization a...

Страница 6: ...e about 10 20 increase Charge current increase can go to zero in hot temperatures whereas charge current increase can easily exceed 30 with a discharged battery and freezing temperatures For a more complete MPPT description see www blueskyenergyinc com PANEL TEMPERATURE AND OUTPUT POWER Internal power control devices use the front panel as a heatsink It is normal for the front panel to become quit...

Страница 7: ...ance Select PV modules that do not exceed the maximum ratings shown below and preferably produce at least 3A of IMP per 100 amp hours of battery capacity Recommended range of VMP at STC Maximum PV Power STC Maximum PV Isc STC Maximum PV VOC STC Nominal 12V PV 340W 20A 28 0V 16 5 18 5V AS SHIPPED FACTORY DEFAULT SETTINGS The 2512 contains various user configurable settings all of which are preconfi...

Страница 8: ...2 1 in lb 0 24 nm CAUTION DO NOT connect Bat and PV together outside of the unit or improper operation will result Bat and PV connect together internally SETUP AND WIRING DIAGRAM FIGURE 3 AUXILIARY OUTPUT Omitted on SB2512i The auxiliary output can serve one of three functions a 2 amp auxiliary battery charger a 25 amp load controller with Low Voltage Disconnect LVD or a 25 amp variable Dusk to Da...

Страница 9: ...n lighting control is enabled the Load output is controlled by both the normal load control function and the lighting control function such that whichever function wants the Load output OFF prevails Dusk or night time begins when the charge control system turns OFF which occurs when PV module current drops below 50mA at battery voltage Dawn or day time begins when the charge control system turns O...

Страница 10: ...ESS MASTER SLAVES DIP SWITCH 0 1 2 3 4 5 6 7 JUMPER A2 NO NO NO NO YES YES YES YES 1 A1 OFF OFF ON ON OFF OFF ON ON 2 A0 OFF ON OFF ON OFF ON OFF ON MOUNTING CAUTION Mount the 2512 vertically to promote air flow and do not enclose in a confined space The 2512 is not watertight and must be protected from rain snow and excessive moisture Take care not to place mounting screws under large brown capac...

Страница 11: ...d battery voltage is high Output during MPPT operation is constant power higher battery voltage reduces charge current increase VMP and available power decrease with increasing PV cell temperature Cooler PV s will produce greater boost It is normal for boost to decrease as PV temperature rises Replace use as is or use different controller for different PV modules Auxiliary battery not being chargi...

Страница 12: ...nt process With IPN ProRemote which may be used as specifications are subject to change without prior notice a setup tool only or permanently installed FIVE YEAR LIMITED WARRANTY Blue Sky Energy Inc hereinafter BSE hereby warrants to the original consumer purchaser that the product or any part thereof shall be free from defects due to defective workmanship or materials for a period of five 5 years...