background image

Puppeteer Plus Board

Controller

Instruction

I

Blue Point   

Pointing the Way to Solutions!

Engineering

www.BPEsolutions.com

9-12 VDC

(BPE No. PCA-0001)

The Puppeteer plus board provides up to 4 minutes of recording and playback time for one servo channel
and one digital (relay) output channel. The board supports sequential recording functions, daisy chaining 
and loop playback with variable inter-loop timing and automatic start-up positioning.

Board Connections

Power Supply Header

The Puppeteer plus board re5V DC supply at currents up to 0.5 amps depending on servo used.

Servo Header

Three pin header to connect to standard servos- observe polarity of servo connection wire (R,B,W)
The Puppeteer plus board generates pcm signals between 0.5 and 2.5msec long repeated every 20msecs. 

Note:

 Most servos are generally only rated for 1-2msec pulses so care should be taken at the extreme 

ends of the travel to ensure the servo motor is not damaged by the extreme travel.

3-Way Terminal Block

Switched relay outputs. The relay is rated at 

24V DC @ 1 Amp

    (NO, Comm, NC terminal connections)

Controls

Go Switch Button

Press and release to record the servo and digital(relay) actions.
Press and release to initiate playback modes.

Go Pins

Used for daisy-chaining multiple Puppeteer plus board - connect subsidiary module Go pins to the sync 
output pins.

R/P Pins

Selects either 

R

ecord mode (jumper 

IN

 place) or 

P

layback mode (jumper 

OUT

).

S/R Pins

Selects either loop playback 

R

epeat (Jumper 

OUT

) or 

S

ingle playback (Jumper 

IN

)

Reset Pins

Resets the Puppeteer plus board. (Briefly short the Reset jumper pin pair to reset the controller)

Servo Connection

Servo Position Adjustment

GO Button

Power Connection 5 Vdc

Playback LED

Record LED

Sync.

Relay LED

EEPROM

Relay Connection

Digital Button

Playback 

LED

Reset

S/R

GO

R/P

Puppet - II+

Battery Cells

- Black

- Red

- Yellow / White

- N/C

- Com

- N/O

Содержание Puppeteer Plus

Страница 1: ...re generally only rated for 1 2msec pulses so care should be taken at the extreme ends of the travel to ensure the servo motor is not damaged by the extreme travel 3 Way Terminal Block Switched relay...

Страница 2: ...quent recording sessions If you move the position control the Green LED will turn OFF and will only re light when the servo is in the exact same position it was at the end of the previous session Remo...

Страница 3: ...Wall Power Adapter GO Button Playback LED Record LED Relay LED GO Sync Reset S R R P Relay Servo Position Control Adjustment Digital Button Relay Connections Configuration Jumpers Caution Check Corre...

Страница 4: ...r Pneumatic Cylinder 12 Vdc Power Supply Pneumatic Tank Air Filter Pressure Regulator Air Hose Pneumatic Valve Air Hose Air Hose Air Hose 12 Vdc 12 Vdc 12 Vdc Wire Wire Wire Pressure Gauge Quick Disco...

Страница 5: ...or improper use of this circuit This circuit should NOT be used for any applications that could cause injury dangerous hazardous situations or consequential damages Use this circuit at your own risk...

Страница 6: ...nal Small DC Motor Control Mode 12 Volt DC Power Supply Relay Connections 24 Volts DC 1 Amp Relay Wire Connection Terminal MOTOR POWER V Gnd 12 Volt DC Permanent Magnet Motor Motor Rotation 12 Volt DC...

Страница 7: ...s Relay Connections 24 Volts DC 1 Amp Relay Wire Connection Terminal Puppeteer Plus Board Puppet Plus Controller Board Optional LED Effect Control Mode 9 Volt dc Power Supply Resistors Blue LED s 2 3...

Отзывы: