background image

A.

 

Introduction

 

 

1.

 

GENERAL INFORMATION 

 

Congratulations on purchasing a high-quality BlueNova® product. 
 

2.

 

DOCUMENT SCOPE 

 

This is a technical support document applicable to the following product(s): 
 
-

 

BlueNova® CPS 5000-Vic 5.2k 

 

The information in this document includes the following 
 
-

 

Product Assembly & Installation Procedures 

-

 

Operating Instructions 

-

 

Maintenance & Troubleshooting Guidelines 

-

 

Emergency Procedures 

 

3.

 

TERMINOLOGY 

 

The table below contains an alphabetical list of industry-specific abbreviations as well as 
product-specific terms used throughout this document: 
 

Term 

Definition 

AC 

  (abbr.)

 

Alternating Current

 (as supplied by utilities & most generators). 

Battery 
  

(term) 

A product subcomponent, in this case specifically 1 x 

BN52V-100-

5.2k DU (Daily Use)

 Lithium Iron Phosphate battery. 

See: 

G. Supporting Documents

 for more technical information. 

Battery Pack 

  (term)

 

Two or more 

BN52V-100-5.2k DU

 batteries connected to each other 

in parallel, up to a maximum of 9. 

BMS 

  (abbr.)

 

Battery Management System

: Battery-integrated electronic circuitry 

& components. Supports cell health, product safety & peripheral 
compatibility functionalities. 

DB 

  (abbr.)

 

Electrical 

Distribution Board

 

Site DB

 refers to the main electrical distribution board (if available) 

of the building or site at which the product will be installed. 
 

DB-A

 or 

DB-B

 refers to either one of the two electrical distribution 

boards integrated as subcomponents within the CPS5000 system 
(see: 

C. Structural Information - 1. Product Layout

DC 

  (abbr.)

 

Direct Current

. Batteries & solar panels supply DC. 

DoD 

  (abbr.)

 

Depth of Discharge

. Refers to a percentage of the total available 

energy capacity of a battery or battery pack. 

Содержание CPS 5000-King

Страница 1: ...Installation Manual CPS 5000 Vic 5 2k...

Страница 2: ...EMENTS C STRUCTURAL INFORMATION 1 LIST OF COMPONENTS 2 PRODUCT LAYOUT D INSTALLATION 1 PRE INSTALLATION 1 1 Product Applications 1 2 Requirements Limitations 1 3 Wiring Diagram 2 STANDARD INSTALLATION...

Страница 3: ...V 100 5 2k DU Daily Use Lithium Iron Phosphate battery See G Supporting Documents for more technical information Battery Pack term Two or more BN52V 100 5 2k DU batteries connected to each other in pa...

Страница 4: ...importance that any all requirements listed below are strictly adhered to Product installation maintenance should be performed by a qualified electrical installer or authorised BlueNova representative...

Страница 5: ...have to be obtained following completion of such installations as per South African legislature CoC documents issued in this regard should be kept safe will be supportive in the event of future warra...

Страница 6: ...The distribution boards in the top section contain the following components The diagram below illustrates the layout of the unit s BN52V 100 5 2k DU battery...

Страница 7: ...at the product integrated inverter is compatible by design with several peripheral hardware components A few applications for which the product can be configured are described below Product Applicatio...

Страница 8: ...figured for such purposes Please see D3 Adding Solar below Familiarising yourself with system subcomponents minimises the risk of failure during product installation For non standard applications of t...

Страница 9: ...l the rawl bolts supplied The top section should be mounted as high as possible without compromising access to the inverter s user interface and or legibility of any information that might be displaye...

Страница 10: ...verter will auto disconnect At temperatures higher than 25 C maximum inverter output will derate to less than 4000W See the inverter manual included with shipment for more information The AC breakers...

Страница 11: ...4 ADDING MORE BATTERIES Additional batteries can be connected to the original battery to increase overall capacity Batteries should be connected as illustrated below...

Страница 12: ...32 RJ11 Not active CAN Ports RJ45 x 2 Serial communication via CAN Bus PIN configuration as follows 7 CAN H 8 CAN L RS485 Ports RJ45 x 2 Pin configuration as follows 1 8 A 2 7 B 3 6 GND 4 5 NC DIP SWI...

Страница 13: ...me capacity on Flash 3 Highest LED Flash 2 OV Protect on on on on on off OC Protect charge limit off off off off off off on Stop charging Charge limit According to real time capacity on off Highest LE...

Страница 14: ...ry display If the batteries are not charged repeat steps 1 to 3 above Should the system not start up at this point please contact BlueNova technical support G Emergency First Aid 1 IN CASE OF FIRE a E...

Отзывы: