background image

STATE-OF-CHARGE:

 

 

COMPONENT 

FUNCTION / DESCRIPTION 

State-of-charge indicator 

 
 
 

 
 

0% 

 25% SoC 

 
 
 
 

 

25% 

 50% SoC 

 
 
 
 
 

50% 

 75% SoC 

 
 
 
 
 

75% 

 100% 

SoC 

 

 

LED indicators: 
 

Status 

Running 

condition 

SOC 

RUN 

ALM 

Description 

 

 

 

 

 

 

Switch Off 

Sleep mode 

off 

off 

off 

off 

off 

off 

All off 

Stand by 

Normal 

off 

off 

off 

off 

Flash 1 

off 

Idle 

Alarm 

off 

off 

off 

off 

Flash 3  Flash 3 

ALM and RUN Flash 

Charging 

Normal 

According to real-time 

capacity 

on 

off 

Highest LED Flash 2 

OV Alarm 

According to real-time 

capacity 

on 

off 

Highest LED Flash 2 

OC Alarm 

According to real-time 

capacity 

on 

Flash 3  Highest LED Flash 2 

OV Protect 

on 

on 

on 

on 

on 

off 

 

OC Protect 

(charge limit 

off) 

off 

off 

off 

off 

off 

on 

Stop charging 

Charge limit 

According to real-time 

capacity 

on 

off 

Highest LED Flash 2 

Discharging 

Normal 

According to real-time 

capacity 

Flash 3 

off 

According to real-

time capacity 

indicate 

Alarm 

According to real-time 

capacity 

Flash 3  Flash 3 

ALM and RUN Flash 

OC/short 

circuit/revere 

connection 

off 

off 

off 

off 

 

off 

on 

Stop discharging 

UV 

off 

off 

off 

off 

off 

off 

Stop discharging 

Temp 

Normal 

According to status 

 

Charge alarm 

According to real-time 

capacity 

on 

Flash 3  Highest LED Flash 2 

Discharge 

alarm 

According to real-time 

capacity 

Flash 3  Flash 3 

 

Protect 

off 

off 

off 

Off 

off 

on 

 

 

Содержание CPS 5000-King

Страница 1: ...Installation Manual CPS 5000 Vic 5 2k...

Страница 2: ...EMENTS C STRUCTURAL INFORMATION 1 LIST OF COMPONENTS 2 PRODUCT LAYOUT D INSTALLATION 1 PRE INSTALLATION 1 1 Product Applications 1 2 Requirements Limitations 1 3 Wiring Diagram 2 STANDARD INSTALLATION...

Страница 3: ...V 100 5 2k DU Daily Use Lithium Iron Phosphate battery See G Supporting Documents for more technical information Battery Pack term Two or more BN52V 100 5 2k DU batteries connected to each other in pa...

Страница 4: ...importance that any all requirements listed below are strictly adhered to Product installation maintenance should be performed by a qualified electrical installer or authorised BlueNova representative...

Страница 5: ...have to be obtained following completion of such installations as per South African legislature CoC documents issued in this regard should be kept safe will be supportive in the event of future warra...

Страница 6: ...The distribution boards in the top section contain the following components The diagram below illustrates the layout of the unit s BN52V 100 5 2k DU battery...

Страница 7: ...at the product integrated inverter is compatible by design with several peripheral hardware components A few applications for which the product can be configured are described below Product Applicatio...

Страница 8: ...figured for such purposes Please see D3 Adding Solar below Familiarising yourself with system subcomponents minimises the risk of failure during product installation For non standard applications of t...

Страница 9: ...l the rawl bolts supplied The top section should be mounted as high as possible without compromising access to the inverter s user interface and or legibility of any information that might be displaye...

Страница 10: ...verter will auto disconnect At temperatures higher than 25 C maximum inverter output will derate to less than 4000W See the inverter manual included with shipment for more information The AC breakers...

Страница 11: ...4 ADDING MORE BATTERIES Additional batteries can be connected to the original battery to increase overall capacity Batteries should be connected as illustrated below...

Страница 12: ...32 RJ11 Not active CAN Ports RJ45 x 2 Serial communication via CAN Bus PIN configuration as follows 7 CAN H 8 CAN L RS485 Ports RJ45 x 2 Pin configuration as follows 1 8 A 2 7 B 3 6 GND 4 5 NC DIP SWI...

Страница 13: ...me capacity on Flash 3 Highest LED Flash 2 OV Protect on on on on on off OC Protect charge limit off off off off off off on Stop charging Charge limit According to real time capacity on off Highest LE...

Страница 14: ...ry display If the batteries are not charged repeat steps 1 to 3 above Should the system not start up at this point please contact BlueNova technical support G Emergency First Aid 1 IN CASE OF FIRE a E...

Отзывы: