6
UV-C lamp
After 5,000 operating hours, the UV-C lamp must be replaced. Ensure that the Compact4pool is always switched off while replacing the lamp. A switch
is integrated inside the lamp holder. When the pre-selector is pulled out of the filter housing with the lamp, the lamp will switch off automatically.
It is only possible to check whether the lamp is on by looking through the transparent connecting piece (
S
) between the filter housing and the pump.
1 Remove the plug from the socket.
2 Using a screw driver, open the heavy fastening clip (
A
) from the screw ring (
C
). Unscrew the pre-selector screw ring (
C
) manually from the filter
housing (
D
). (
see drawing 3
).
3 Slide the transformer slightly backwards and carefully click the UV-C lamp (
P
) out of the lamp holder (
Q
); put the transformer temporarily to the side.
4 Remove the used UV-C lamp from the quartz glass and carefully place the new replacement UV-C lamp in the quartz glass.
5 Fix the lamp holder (
Q
) of the pre-selector (
B
) to the new lamp. As these parts are very fragile, caution is essential.
6 Test the operation of the lamp via the transparent connection piece between the filter and the pump (see item 5 of the chapter on installation).
7 Following this, re-fit the complete transformer to the filter housing by means of the screw ring (
C
) and the fastening clip (
A
).
Pump
The Compact4pool pump is practically maintenance-free. If you would like to clean the pump, or dismantle it for other reasons, always remove the
plug from the socket first.
1 Disconnect the inlet and outlet couplings (
E & R
), and unscrew the connection (
I
) between the filter housing and the pump (
J
).
2 Unscrew the black plastic nuts (
L
) from the bracket (
K
) and remove the bracket from the support (
M
) (
see drawing 3
).
3 Open the filter housing and click the filter housing loose from the support using a flat screwdriver.
4 After removing the four screws on the pump head, it is possible to open and clean the pump housing of the Compact4pool pump (
see drawing 5
).
The pump wheel forms an integrated unit with the rotor, and can be removed. These components have been manufactured in a high-quality,
but brittle ceramic material (breakage hazard!). No lubricants should be applied. The electric motor is encapsulated and must never be
dismantled! If in doubt with regard to the connection, consult a recognized fitter.
5 Clean the Compact4pool under running water (do not use a high-pressure cleaner or aggressive cleaning agents). The plug and the UV-C lamp
should never become wet! Reassemble the pump after cleaning and tighten the screws cross-wise onto the pump housing.
6 Tighten the couplings (
E & R
) and couple the transparent connecting piece (
S
) between the filter housing and the pump.
Technical specifications
• UV-C PL LTC KLVE
11 Watt
• Power consumption
81 W
• UV-C output (W)
3, 4 Watt
• Pump capacity
5000 l/h
• UV-C (%) after 5,000 hours
85%
• Max. discharge head
2.6 m
• Swimming pool content (l)
20,000 l
• Outlet size
Ø 40 mm
• Max. temperature
25 °C
• Cable length
10 m
• Mains voltage
220-240 V /50 Hz
• Weight, incl. cable
3.7 kg
Terms of guarantee
The guarantee of this product covers manufacturing faults for a period of 24 months following the date of purchase. The lamp and the quartz glass
are not included in this guarantee. Claims under the guarantee can only be considered if the product is returned post-paid together with a valid
purchase receipt. Repairs under the guarantee may exclusively be carried out by the supplier. Guarantee claims that are caused by errors in the
installation or operation of the unit will not be considered. Defects originating from poor maintenance are also excluded from the guarantee.
Consequential damage is excluded from the guarantee. Components that are subject to wear and tear, such as rotors, are not included in the
guarantee. In no way whatsoever can the supplier be held responsible for any damage caused by the incorrect use of the product. The supplier will
not be liable for consequential damage caused by any breakdown of the unit. Complaints regarding transportation damage will only be
considered if the damage was established or confirmed on delivery by the carrier or the postal authorities. A claim can only be made against the
carrier or the postal authorities if this has been done.
Содержание Compact4pool
Страница 1: ...1 The easy and friendly way to disinfect your pool Blue Lagoon Compact4pool ...
Страница 2: ...2 2 1 E K R N K A I S J B O P Q C D L L M ...
Страница 3: ...3 5 4 3 1 3 4 2 2m 6 2m 2m 2m ...
Страница 58: ...58 2 1 E K R N K A I S J B O P Q C D L L M ...
Страница 59: ...59 5 4 3 1 3 4 2 2m 6 2m 2m 2m ...