background image

© 2009 Blue Angel™ Pumps

330804-002 12/09

Sewage Pump

CSE40M, CSE40T  

CSE40T-2 and BCAPSE40 

Operating Instructions and Parts Manual

Please read and save these instructions. Read carefully before 

attempting to assemble, install, operate or maintain the product 

described. Protect yourself and others by observing all safety 

information. Failure to comply with instructions could result in 

personal injury and/or property damage! Retain instructions for 

future reference.

Description

A sewage pump is intended for use in 
domestic sewage lift stations. It is suitable  
for pumping sewage, effluent, wastewater, 
groundwater, and other nonexplosive, 
noncorrosive liquids with up to 2 inch solids. 
The pump is controlled by a switch with a 
piggyback style plug which accepts the pump 
plug and, in turn, plugs into a 120-volt outlet. 
The float switch is a wide angle differential 
switch that rises with the liquid level and turns 
the pump on. As the liquid level decreases, 
the float lowers and turns the pump off.
The BCAPSE40 is provided with a solid-
state electronic water level control. When 
water is detected, the pump will start 
automatically. This pump is intended for 
use in domestic sewage lift stations.

Unpacking

Inspect this unit before it is used. 

Occasionally, products are damaged 

during shipment. If the pump or 

components are damaged, return 

the unit to the place of purchase for 

replacement. Failure to do so could 

result in serious injury or death.

The Professional’s Line

For parts, product & service information

visit 

www.blueangelpumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!  

Attach it to this manual or file it for safekeeping.

Performance

GAllONS PER MINUTE AT TOTAl 

hEAD IN fEET

5

10

15

90

62

23

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

Danger indicates  

  an imminently 

hazardous situation which, if not avoided, 

WILL result in death or serious injury.
 

Warning indicates  

  a potentially 

hazardous situation which, if not avoided, 

COULD result in death or serious injury.
 

Caution indicates  

  a potentially 

hazardous situation which, if not avoided, 

MAY result in minor or moderate injury.
 

Notice indicates  

  important 

information, that if not followed, may 

cause damage to equipment.

General Safety 

Information

CAlIfORNIA PROPOSITION 65

 

This product or its  

  power cord contains 

chemicals known to the State of 

California to cause cancer and birth 

defects or other reproductive harm. 

Wash hands after handling.

GENERAl SAfETy

1.  Know the pump application, 

limitations, and po ten tial hazards.

 

Do not  

  use to  

pump flammable or 

explosive fluids such as 

gasoline, fuel oil, kerosene, 

etc. Do not use in a 

flammable and/or explosive atmosphere. 

Use pump only with liquids compatible 

with pump component materials. Failure 

to follow this warning can result in 

personal injury and/or property damage.

2.  Make certain that the power source 

(electric motor) conforms to the 

requirements of the equipment.

 

  

 

Disconnect power before 
servicing. If the power 
dis con nect is out of sight, 
lock in the open po si tion and tag it 
to prevent unexpected application of 
power. Failure to do so could result in 
fatal electrical shock!

Specifications

BCSE50M & BCSE50T

BCAPSE50 & 
BCAPSE50-2

Power supply requirements

120V, 60 hz

120V, 60hz

Circuit requirements

15 amps (min)

15 amps (min)

Motor duty

Intermittent

Intermittent

Motor

120V, 1 Phase

120V, 1 Phase

Horsepower 

4/10

4/10

Motor full load

12.0 amps

8.7 amps

Liquid temperature range

40°F to 120°F

40°F to 120°F

Max. operating position

45o from vertical

45o from vertical

Dimensions

14 inch x 12 inch

14 inch x 12 inch

Intake

2 inch

2 inch

Discharge

2 inch NPT female

2 inch NPT female

Cut-in level (factory set)

19 inch

11 inch

Cut-out level (factory set)

9 inch

3 inch

Differential

10 inch

7 inch

Switch

90° wide angle 
mechanical tether switch

Capacitive water sensor

Power cord

16 gauge 3 conductor 
with plug

16 gauge 3 conductor 
with plug

Construction

Motor  

body material  ..........  Cold rolled steel
Motor housing  ...................... Cast iron
Volute  .................................... Cast iron
Impeller  .............. Glass reinforced PBT
Seal plate  .............................. Cast Iron
Shaft seal  ........................... Mechanical

Содержание BCAPSE40

Страница 1: ...death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may cause damage to equipment General Safety Information California proposition 65 This pro...

Страница 2: ...p 14 This pump is designed to transfer water in cycles Using this pump in a continuous duty application by ma nip u lat ing the switch to stay on will affect the per for mance and the life of the product 15 Protect electrical cord from sharp objects hot sur fac es oil and chemicals Avoid kinking the cord Re place or repair damaged or worn cords im me di ate ly Use wire of adequate size to minimize...

Страница 3: ...s for proper op er a tion If anything has changed since unit was new the unit should be removed and repaired or replaced Only qualified electricians or service peo ple should at tempt to repair this unit Improper repair and or assembly can cause an electrical shock hazard 4 Place the pump in a suitable area where it can be cleaned thoroughly Remove all scale and deposits on pump 5 Submerge the com...

Страница 4: ...3 Low line voltage 1 Pump should not be used for water above 120º F 2 Replace or reposition pump Pump may start unexpectedly Disconnect power supply before ser vic ing 3 If voltage is under recommended min i mum check wiring size from the main switch on property If OK contact power company Pump operates noisily or vibrates excessively 1 Worn bearings 2 Debris in impeller cavity or broken 3 Piping ...

Страница 5: ...lease provide following information Model number Serial number if any Part description and number as shown in parts list Address parts correspondence to Blue Angel Pumps 101 Production Drive Harrison OH 45030 U S A CSE40M CSE40T CSE40T 2 and BCAPSE40 1 Capacitive Water Sensor 30037 002 1 2 Power Cord BCAPSE50 31035 001 1 3 Impeller 17317 001 1 4 Volute 41027 001 1 5 Motor Assembly 8322 1 with Shaf...

Страница 6: ...ONSEQUENTIAL DAM AG ES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above lim i ta tions might not apply to you This limited war ran ty gives you specific legal rights and you may also have other legal rights which vary from state to state In ...

Страница 7: ...tion hasardeuse potentielle qui PEUT résulter en perte de vie ou blessures graves Attention indique une situation hasardeuse potentielle qui PEUT résulter en blessures Avis indique de l information importante pour éviter le dommage de l équipement Généralités Sur La Sécurité PRoposition 65 DE CALIFORNIE Ce produit ou son cordon peuvent contenir des produits chimiques qui de l avis de l État de Cal...

Страница 8: ...cien local pour la disponibilité et l installation Le moteur de la pompe est équipé d un protecteur thermique à réenclenchement automatique et peut se mettre en marche subitement Le déclenchement du protecteur est une indication de surcharge du moteur résultant du fonctionnement de la pompe à basse pression restriction de décharge basse tension extrèmement élevée ou basse installation de fils insu...

Страница 9: ...ait essayer de réparer ce modèle La réparation incorrecte peut causer un hasard de secousse électrique La pompe contient de l huile qui peut être sous pression à cause de la chaleur Permettre que la pompe se refroidisse pour un minimum de deux heures avant de procéder à l entretien de ce modèle 1 Démonter le moteur avant l expiration de la garantie annulera la garantie Il est aussi possible de cau...

Страница 10: ...e à l édifice trop rigides ou trop desserrés 1 Retourner pour l entretien ou remplacer 2 Enlever le carter nettoyer la turbine et ou remplacer la turbine en panne 3 Remplacer la section de tuyau de décharge avec un raccord flexible La pompe ne s arrête pas 1 Mouvement de l interrupteur flotteur limité 2 Décharge limité tuyauterie obstruée 3 Arrivée excessive ou pompe de taille incorrecte pour l ap...

Страница 11: ...r à flotteur ancré CSE40T 30000 009 1 Interrupteur à flotteur ancré CSE40T 2 30000 003 1 2 Cordon d alimintation CSE40T 31035 001 1 Cordon d alimintation CSE40M CSE40T 2 31036 001 1 3 Rotor 17317 001 1 4 Volute 41027 001 1 Ref Part No Description Number Qty 1 Le capteur d eau capacitif 30037 002 1 2 Cordon d alimentation 31035 001 1 10 pi 3 Rotor 17317 001 1 4 Volute 41027 001 1 5 Assemblage du mo...

Страница 12: ...AGES INDIRECTS OU DÉPENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de durée pour les garanties implicites ni l exclusion ni la limitation des dom mages fortuits ou indirects Les limitations précédentes peuvent donc ne pas s appliquer Cette garantie limitée donne à l acheteur des droits légales précis et vous pouvez avoir autres droits légales qui sont variab...

Страница 13: ...indica que hay una situación que PODRIA ocasionarle heridas no muy graves Ésto le indica una información importante que de no seguirla le podría ocasionar daños al equipo Informaciones Generales de Seguridad PROPOSICIÓN DE CALIFORNIA 65 Este producto o su cordón eléctrico puede contener productos químicos conocidos por el estado de California como causantes de cáncer y defectos de nacimiento u otr...

Страница 14: ...mente recomendable que utilice un tomacorrientes que tenga un sistema de cortacircuito incorporado Con súltele a un electricista local para ver si éstos están disponibles en su área El motor de la bomba tiene un sistema de protección térmica y puede comenzar a funcionar sin previo aviso Si este sistema se activa es una indicación de que el motor está sobrecargado debido a que la distancia de desca...

Страница 15: ... De lo contrario podría ocasionar peligro de electrocutamiento Esta bomba contiene aceite que podría estar bajo presión debido al calor Espere a que la bomba se enfríe por lo menos durante 2 horas antes de darle servicio 1 Si desmantela el motor antes de la fecha de expiración de la garantía esta quedaría cancelada Igualmente podría ocasionar fugas internas y daños a la unidad Si necesita reparaci...

Страница 16: ...resa de las tuberías 2 Sensor de agua Interruptor sucio 3 El interruptor flotante está dañado 4 No instaló una válvula de chequeo o la válvula de chequeo tiene una fuga 5 La distancia de la descarga es inferior al mínimo recomendado por el fabricante 1 Instale una válvula de chequeo 2 Cambie la posición de la bomba limpie la superficie del sensor 3 Reemplace el interruptor flotante 4 Desconecte la...

Страница 17: ...r al mínimo recomendado chequée el alambrado del circuito principal de la propiedad Si es adecuado comuníquese con la compañía de electricidad 2 Desconecte el impulsor límpielo y cerciórese de que esté bien instalado 3 Reemplace las piezas dañadas o toda la bomba Si es necesario limpie las piezas que estén sucias 4 Chequée la rotación Sentido contrario al de las agujas del reloj al observarlo desd...

Страница 18: ...U S A 1 Interruptor de flotador de correa CSE40T 30000 009 1 Interruptor de flotador de correa CSE40T 2 30000 003 1 2 Cordón de corriente CSE40T 31035 001 1 Cordón de corriente CSE40M CSE40T 2 31036 001 1 3 Impulsor 31047 001 1 4 Caja espiral 17317 001 1 Ref Part No Description Number Qty 1 Sensor de agua capacitivo 30037 002 1 2 Cordón de corriente 31035 001 1 de 3m 10 pies 3 Impulsor 17317 001 1...

Страница 19: ...Notas 19 Sp CSE40M CSE40T CSE40T 2 y BCAPSE40 ...

Страница 20: ...STOS POR DAÑOS INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS Algunos estados no permiten que se establezcan límites en la duración de las garantías implicitas o no permiten que se excluyan ni se establezcan límites en los daños por incidentes o consecuencias por lo tanto los límites antes mencionados podrían ser no válidos Esta Garantía Limitada le otorga derechos legales especificos y usted también ...

Отзывы: