PREP TABLE
PAGE 8
START UP PROCEDURE
1. Ensure doors to refrigerated base are closed and night cover is lowered to cover pan chiller top.
2. On the front side of the unit in the compressor compartment area, flip the main power switch ON.
3. Replace louver panel to cover opening of compressor compartment.
4. Observe the blue LED Temperature Display located just above the louver panel. (See Fig. 4)
5. At start-up, the readout will read H1. This signifies that the temperature is above normal operating
range. The reading will alternate every 5 seconds, displaying the refrigerated cabinet temperature
and the glycol liquid temperature.
6. When the liquid temperature cools to 30°F, the unit is ready to go!
4. STARTUP INSTRUCTIONS (CONT.)
FIG. 4
4A - REFRIGERATION LINES
WARNING:
GAS REFRIGERATION LINES IN CONDENSING UNIT AREA ARE SHIPPED UNDER PRESSURE
Содержание K99597F15
Страница 1: ...INSTRUCTION MANUAL KBP PREP TABLE ...
Страница 20: ...NOTES ...