Blower Engineering Instructional Manual
3
2.2 Working conditions
2.2.1 Speed of rotation –
The maximum speed of rotation is shown in Table I. The minimum
speed of rotation depends on the maximum allowed differential temperature.
2.2.2 Pressure –
The inlet pressure ranges from 3 psig (20.7 kPa) to 15 psig (103.4 kPa). The maxi-
mum differential pressure is shown in Table I, and depends on the size of the blower. The maximum
compression ratio for all sizes of blowers is 2.
2.2.3 Temperature –
The inlet temperature of the gas ranges from -13ºF (-25ºC) to 122ºF (50ºC).
The maximum differential temperature allowed is shown in Table I, and depends on the size of
the blower. The maximum temperature of the gas allowed at the discharge is 266ºF (130ºC).
Table I: Operation Limits
2.3 Capacity adjustment
Capacity can only be adjusted in one of the two following ways:
• Varying the speed of rotation. This can be achieved via belt drives
or
by varying the
electric motor supply voltage frequency
or
with a double polarity motor.
• Bleeding off of excess capacity via a regulating valve on the outlet
Do not use the safety valve for this purpose because it will suffer excessive wear.
Do not re-circulate the excess gas into the blower inlet without cooling because it could
cause excessive heating.
WARNING: Do not adjust the gas capacity by using throttle valves placed on the
inlet or outlet piping.
TL
Arrangement
Delta T
Size
Vertical
Horiz.
psig
“Hg
ºF
ºC
TL10
4800
4800
13
13
190
105
TL20
4800
4800
13
13
190
105
TL30
4800
4800
15
15
200
110
TL40
4800
4800
15
15
200
110
TL41
4800
4800
11
12
165
90
TL50
4800
3000
15
15
200
110
TL60
4800
3000
15
15
200
110
TL61
4800
3000
11
12
165
90
TL70
3800
2200
15
15
200
110
TL80
3800
2200
15
15
200
110
TL81
3800
2200
11
12
165
90
TL90
3000
1900
15
15
200
110
TL100
3000
1900
15
15
200
110
TL101
3000
1900
10
12
150
83
TL110
2400
1500
15
15
200
110
TL120
2400
1500
12
13
180
100
TL600
1800
1125
15
15
200
110
TL900
1800
1125
12
13
180
100