background image

INSTALLATION INSTRUCTIONS

READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION

REFER TO EXPLODED VIEWS PAGES 18 - 21 FOR
COMPONENT NAMES/NUMBERS

Unpack the unit.  Inspect all components for completeness and 
condition.  Ensure that all packing materials have been removed 
from the unit. 

Verify that the Spray Head Gasket (#33) and Spray Disk (#34) 
are properly installed.  

LEVELING THE UNIT

Verify that an adjustable leg is installed at each corner of the 
brewer, and that a rubber foot is installed on each leg.

Set Brewer in its operating location.  Level the Brewer.  A spirit 
level should be placed on the top of the unit, at the edge, as a 
guide when making level adjustments.

Level the unit from left to right and front to back by turning the  
adjustable feet.  Be sure all four feet touch the counter to prevent 
tipping.

PLUMBER’S INSTALLATION INSTRUCTIONS 

Brewer should be connected to a 

POTABLE WATER, COLD 

WATER

 line.  Flush water line before connecting to Brewer. 

DO NOT use a saddle valve with a self-piercing tap for the water 
line connection.  Such a tap can become restricted by waterline 
debris.  For systems that must use a saddle tap,  shut off the 
main water supply and drill a 3/16” (minimum) tap for the saddle     
connection, in order to insure an ample water supply.  Remember 

WRÀXVKWKHOLQHSULRUWRLQVWDOOLQJWKHVDGGOH

The brewer must be installed on a water line with average     
pressure between 20 PSI and 90 PSI.  If your water pressure   
exceeds 90 PSI at anytime, a pressure regulator must be
installed in the water supply  line to limit the pressure to not more 
than 90 PSI in order to avoid damage to lines and solenoid.

3OXPEHUPXVWSURYLGHWZR´IHPDOHÀDUHZDWHUVXSSOLHVIRUWKLV

brewer.

A water shut-off valve should be installed on the incoming water 
line in a convenient location (Use a low restriction type valve, 

VXFKDVDWXUQEDOOYDOYHWRDYRLGORVVRIZDWHUÀRZWKUXWKH

valve.

IMPORTANT:

To enable the installer to make 
a quality installation and to  
minimize installation time, the 
following suggestions and tests 
should be done before the     
actual unit installation is started:

CAUTION:

EQUIPMENT DAMAGE

DO NOT plug in or energize this 
appliance until all Installation 
Instructions are read and       
followed.  Damage to the 
Brewer will occur if these
instructions are not followed.

CAUTION:

UNSTABLE
EQUIPMENT HAZARD

It is very important for safety 
and for proper operation that the 
brewer is level and stable when 

VWDQGLQJLQLWV¿QDORSHUDWLQJ

position.  Provided adjustable, 
non-skid legs must be installed 
at each corner of the unit.    
Failure to do so will result in 
movement of the brewer which 
can cause personal Injury and/
or damage to brewer.

NOTE:

  Water supply inlet line 

must meet certain minimum
criteria to insure successful
operation of the brewer.

%ORRP¿HOGUHFRPPHQGV´

copper tubing for installation of 
less than 12 feet and 3/8” for 
more than 12 feet from a 1/2” 
water supply line.  

4

C

E

DO NOT

C

C

U
E

625 p/n 2M-75873 8792, 8793 Dual Coffee Brewer

Содержание GOURMET 1000 8792

Страница 1: ...ER MODEL 8792 Includes Installation Operation Use Care Servicing Instructions 2060 Cessna Dr Suite 100 Vacaville CA 95688 telephone 707 448 5151 fax 707 448 1521 www bloomfieldworldwide com Model 8792...

Страница 2: ...pensers i e tea and coffee carry a 90 days parts warranty only excludes decanters c decanters are not covered by this warranty THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTI...

Страница 3: ...RMATION 3 INSTALLATION INSTRUCTIONS 4 OPERATION 6 BREWING COFFEE 8 CLEANING INSTRUCTIONS 9 TROUBLESHOOTING SUGGESTIONS 10 SERVICING INSTRUCTIONS 11 16 EXPLODED VIEWS PARTS LISTS 18 WIRING DIAGRAMS 22...

Страница 4: ...BREW CHAMBERS REMOVED BREW NOZZLE SPRAY HEAD GASKET TIMER ACCESS SPRAY DISK AIRPOT BREWER AIRPOT BREWING POSITION BREW CHAMBER BREW SWITCH READY TO BREW LIGHT POUR OVER OPENING POUR OVER COVER HOT WAT...

Страница 5: ...appliance use limitations and associated hazards Operating instructions and warnings must be read and understood by all operators and users Except as noted this piece of equipment is made in the USA a...

Страница 6: ...sure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order t...

Страница 7: ...LQH EHWZHHQ WKH EDFN RZ SUHYHQWHU DQG WKH brewer inlet as far away from the brewer as space will allow 7KLV ZLOO UHOLHYH WKH H FHVVLYH EDFN SUHVVXUHV WKDW FDQ FDXVH faucet leaks and solenoid malfuncti...

Страница 8: ...out 3 full 64 oz decanters of water per side Once both tanks are full of water connect the brewer to electrical power The heating elements will begin heating the water in the WDQN KHQ WKH ZDWHU KDV UH...

Страница 9: ...water tank This forces an identical amount of hot water out of the tank and through the spray head into the brew chamber 7KH VROHQRLG XVHV D RZ FRQWURO GHYLFH VR WKDW RZ LV FRQVLVWHQW EHWZHHQ S V L DQ...

Страница 10: ...ap water Lift the pour over cover and pour the entire contents of the FRQWDLQHU LQWR WKH SRXU RYHU RSHQLQJ ZKLFK ZLOO OO WKH EDVLQ Water from the basin will displace a like amount of heated water from...

Страница 11: ...rm water and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry Wipe the exterior of the brewer with a soft clean cloth or sponge moistened wi...

Страница 12: ...WHU per brew Brew chamber dispense hole plugged Thoroughly clean brew chamber Too much cofIHH RU WRR QH D JULQG Adjust coffee amount and grind Sprays water from brew head Spray gasket improperly insta...

Страница 13: ...held by two screws at the bottom and a retaining lip at the top SOLENOID DOOR Remove solenoid door to access solenoid plumbing connections Each solenoid door is held by two screws and a retaining lip...

Страница 14: ...CAUTION SHOCK HAZARD These procedures involve exposed electrical circuits These procedures are to EH SHUIRUPHG E TXDOL HG technical personnel only NOTE Optimum brewing temperature range is 195 F to 20...

Страница 15: ...EMOVE TANK LID ASSEMBLY 8QSOXJ EUHZHU RU WXUQ FLUFXLW EUHDNHU OFF Turn OFF water supply 5HPRYH WRS SDQHO 3XOO YHQW WXEH DQG LQOHW HOERZ RXW RI basin pan 3XOO ZDWHU LQOHW WXEH RXW RI EDVLQ SDQ 5HPRYH E...

Страница 16: ...hose to be easily slid off of the solenoid bypass outlet c Install hose on new valve by pressing end of hose onto bypass outlet until it is fully seated Disconnect wiring Remove two screws holding sol...

Страница 17: ...FHSW ZKHQ IDXFHW YDOYH LV WXUQHG 2 5HPRYH WDQN OLG DVVHPEO SHU DERYH 5HPRYH WZR KH QXWV KRW ZDWHU FRLO WR FRYHr Pull coil from mounting holes 5HDVVHPEOH LQ UHYHUVH RUGHr REPAIR HOT WATER FAUCET 5HPRYH...

Страница 18: ...up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solution according to the manufac turer s directions Carefully pour the deliming solution into the water...

Страница 19: ...49 HOT WATER COIL RIGHT SIDE ONLY S E D I S H T O B ELBOW INLET Z18254 K 2 9 5 60 2V 70102 TUBE VENT SILICONE BOTH SIDES S E D I S H T O B E N O C I L I S T E L T U O K N A T W O B L E 3 0 1 0 7 K 2 1...

Страница 20: ...1 0 7 C 2 7 2 E D I S T H G I R S S 6 1 1 x 8 1 1 x 2 3 5 1 T A L F R E H S A W 1 8 6 2 7 C 2 8 2 29 WS 82556 FAUCET ASSEMBLY PRESSURE RIGHT SIDE 33 2I 70139 GASKET SPRAY HEAD ALL 34 A6 72727 SPRAY D...

Страница 21: ...RIGHT SIDE 2E 75754 SOLENOID SINGLE 120V 50 GPM LEFT SIDE 2E Z16608 SOLENOID BYPASS 120V 30GPM 8792AF 240V 2E Z16741 SOLENOID SINGLE 120V 30GPM 8792AF 240V 50 WS 812 51 T STAT BLACK GRAY BODY INCL SEA...

Страница 22: ...TH 72 Support Lower BOTH 73 2A 71732 LEG ASSEMBLY LEVELLING BOTH 75 2K 70229 BUSHING HEYCO BOTH 101 ASSEMBLY BODY BOTH 102 FRONT PANEL BOTH 104 2Q 75089 DOOR SOLENOID ACCESS PLASTIC BOTH 105 2F 76666...

Страница 23: ...WIRING DIAGRAM 22 p n 74810 625 p n 2M 75873 8792 8793 Dual Coffee Brewer...

Страница 24: ...2060 Cessna Dr Suite 100 Vacaville CA 95688 phone 707 448 5151 fax 707 448 1521 www bloomfieldworldwide com...

Отзывы: