PROGRAMMING - OPERATOR LEVEL (continued) 

12. View 

Filter 

Statistics: 

 To view filter statistics, turn the brewer off.  Press and hold the 1st key 

 

(Brew), and depress the 3rd (ON/OFF) key.  Total water volume will be displayed (TotalVol.).  

 

Press the 3rd key to view the Filter Life (FltrLife:).  Press the 3rd key to view the percentage of 

 

the filter that has been used.  (If the filter option is used, the filter life volume needs to be entered 

 

in the program – see page 14, Service & Counters Menu.)  

 

13.  Diagnostic Messages – Programmed Safety Features:

  When the E-Max™ senses a problem,   

 

it will automatically turn off all elements and valves, flash lights, display the message  

 

Call For Service

” and  display one of the messages below.  (Additionally:  a service phone  

 

number may appear if it has been programmed  into the system.)   

        *  To reset the brewer it can be re-energized (or press and hold the 2nd key for 3 seconds for all 
 

 

faults except the Valve Fault, which must be reset by re-energizing).  The brewer will try to        

 

 

re-start, but if the same problem persists, the appropriate error message will appear again.   

 

 

Consult the Trouble Shooting section to determine how  to solve the problem. 

 

A.  “Probe/Heater Error”

:  Overheating Detection (1): If the heating element is on for 5  minutes 

 

 

and the temperature does not change by +2°F (1°C) in the five minute period,  the unit will go 

 

 

into the Over Temperature Mode 

with all lights flashing

.  When in this mode the brewer turns 

 

 

off  the heating elements, the solenoid valves are turned off; the switches disabled; (and all 

 

 

lights flashing continuously).  The LCD display will read “

Probe/Heater Error

”, followed by the       

  

message 

Call for Service

”, and then the service phone number (if it has been entered into 

 

 

memory).  To reset press and hold the 2nd key for 3 seconds, or re-energize the brewer.   

 

 

(Possible causes of problem: high limit needs to be re-set; defective high limit, element, triac, 

 

 

water level probe or control board.) 

 

B.  “Overheat Error”:

  Overheating Detection (2):  If the E-Max™ senses a temperature over the 

 

 

 Maximum Temperature set in the program (factory set at 208ºF or 98ºC) it will go into the over 

 

 

 temperature mode as above with all lights flashing, except the LCD will read “

overheat error

”,  

  

and 

Call for Service

”. To reset press and hold the 2nd key for 3 seconds, or re-energize the 

 

 

brewer. (Possible cause of problem is a defective triac, temperature probe or related wiring 

  

and 

connections.) 

 

C.  “No Water Sensed” — Time-Out —Inlet Valve:

 When filling for the first time, the inlet valve 

 

 

 will remain open for 4¼ minutes, (the screen will read “

filling…

”).  If water is not detected at 

 

 

the end of this time the E-Max™ will shut down with the message “

no water sensed

”.  The 

 

 

 valves and all elements are turned off, and the Brew and Power light flash alternately with the 

 

 

Heat light, until the brewer is reset.  To reset press and hold the 2nd key for 3 seconds, or         

 

 

re-energize the brewer. (Possible causes of the problem are: no incoming water; slow flow of  

 

 

incoming water (i.e. less than 45 oz/minute); sensor not reading (check for placement,       

 

 

connections or lime scale). 

 

D.  “No Water Sensed” — Time-Out – Brew Valve:

 During the brew the inlet solenoid valve 

 

 

 cycles on intermittently to maintain the proper level in the tank.  If the valve is open for          

 

 

60 seconds without water being detected at the proper level, the brewer will go into the same 

 

 

error mode as above (“

no water sensed

”). To reset press and hold the 2nd key for 3 seconds, 

 

 

or re-energize the brewer. (Possible causes of the problem are: no incoming water; slow flow 

 

 

of incoming water, sensor not reading, etc.). 

 

E.  Keyswitch Locked:  

If a key switch is depressed for 10 seconds this error message will  

 

 

occur.  Lights will flash alternately and the brewer will turn off all valves and elements.  Press 

 

 

and hold the 2nd key for 3 seconds to reset the brewer (or re-energize the brewer).  If the 

 

 

problem re-occurs this indicates a defective switch on the key pad. 

 

F.  “Valve Fault”-  Faulty Valve Detection:

 When an electric or switching problem is detected 

 

 

with either the inlet or brew valve the brewer turns off all elements and valves and displays 

 

 

valve fault…

”.  All of the lights will be turned on.  Before re-setting the brewer the valves 

 

 

must be checked to determine the problem.  The brewer must be re-energized to re-set,  

 

 

(pressing the 2nd key for 3 seconds will not reset a valve fault). 

654 p/n 

73674

 E-Max™ 

Prog

ra

mm

ing 

M

a

n

ual 

Содержание E-MAX

Страница 1: ...NV 89439 telephone 888 492 2782 fax 888 492 2783 www wellsbloomfield com p n 73674 Rev I ECN 13315 M654 070718 cps 654 PROGRAMMING MANUAL for E MAX COFFEE AND TEA BREWERS E Max BREWERS are covered un...

Страница 2: ...CALIBRATION 18 PULSE BREW AND PRE INFUSION 19 TEST PROGRAM E MAX 24 ADDENDUM Extract of Service Bulletin 26 xi Thank You for purchasing this Wells Bloomfield appliance Proper installation professional...

Страница 3: ...structions and warnings in the corresponding Service Manual must be read and understood by all operators and users Except as noted this piece of equipment is made in the USA and has American sizes on...

Страница 4: ...gular operating mode the E Max maintains the tank temperature within 1 F of the brew temperature Normally this will mean that a brew will be started as soon as the BREW key is pressed However there ma...

Страница 5: ...the spray head Place one 1 genuine Bloomfield paper filter into the brew chamber Add your choice of pre measured ground coffee Shake the brew chamber gently to level the coffee Slide the brew chamber...

Страница 6: ...Key 6 AIRPOT THERMAL BREWERS TEA BREWERS WITH VOLUME KEY 1 BREW Key 1 2 BREW CANCEL Key 2 3 POWER Key 3 4 STANDARD VOLUME Key 4 5 SMALL VOLUME Key 5 6 LARGE VOLUME Key 6 TEA BREWERS WITHOUT VOLUME KE...

Страница 7: ...e brewer will remain ON until the automatic programmed off time when it will turn OFF and resume normal automatic timed functioning Similarly if turned OFF during the automatic timed ON mode the brewe...

Страница 8: ...rmal operation heating the water to the Precise Temperature for Brewing PTB before starting the brew The power light will be on continuously and the Brew light will flash until the correct water tempe...

Страница 9: ...it will go into the over temperature mode as above with all lights flashing except the LCD will read overheat error and Call for Service To reset press and hold the 2nd key for 3 seconds or re energi...

Страница 10: ...brewers and on Tea brewers with volume keys the 4th key is STANDARD Volume and the 6th key is Large Volume On Tea brewers without volume keys the 4th key is hidden under the E and the 6th key is hidd...

Страница 11: ...then press 3rd key ON OFF ITEM to get to the required ITEM 3 To Increase Decrease or Change settings when in the programming mode press the 5th or 6th keys Suggestion If the key is pressed and held t...

Страница 12: ...10 PROGRAMMING TABLE 654 p n 73674 E Max Programming Manual...

Страница 13: ...11 PROGRAMMING TABLE continued 654 p n 73674 E Max Programming Manual...

Страница 14: ...Vol 1 This number will be displayed on the LCD when volumes are being changed Pulse Brew To access the pulse or pre infusion programs terminate Brew Vol with the 4th key See Pulse Brew details outline...

Страница 15: ...6th keys Decanter Brewers If the Quality Timer is activated each warmer plate will count down from the programmed time when the warmer plate is turned on Once the count down time is reached the appro...

Страница 16: ...n the keypad switches can only be activated by pressing and holding the CANCEL key for 6 seconds Then the keypad will be active until a brew has been completed Or if a brew is not started the keypad w...

Страница 17: ...e re loaded value if defaults are loaded Re loading of defaults should be used only if major programming problems have occurred and it is necessary to return to factory settings 15 MAX WATER LOCATION...

Страница 18: ...Calibration is on the screen The probe is factory set and should not need resetting unless the control ler board or probe is changed See Calibration Instructions following the Factory Settings menu it...

Страница 19: ...ce empty decanter or other vessel under the faucet and begin drawing water from the faucet 6 When the inlet valve comes on stop drawing water from the faucet and count the number of seconds before the...

Страница 20: ...out the level sensor Insert the thermometer into the brewer Allow time for the thermometer temperature to stablize 5 Once the actual tank temperature has been established look at the values on the scr...

Страница 21: ...the water over a longer period of time thus preventing any overflow problems 1 Select the Brew Volume that will be using the pulse brew feature i e go to selected volume BrewVol1 2 3 or 4 in the Brew...

Страница 22: ...is required this will also be calculated automatically The outflow rate of water from the spray head is required to calculate valve time for different volumes Spray head outflow rates are based on th...

Страница 23: ...ucing 3 pulse cycles each with a 20 second delay Init Vlv Time 10 Pulse Delay 20 Pulse Valve On 54 Total Valve 172 21 1 PRE INFUSION ON ON OFF 30 sec 20 sec 152 sec OFF DRIP OUT 60 sec One Pulse Cycle...

Страница 24: ...36 Pulse Valve On 58 Total Valve 236 Pulse Feature Examples TEA BREWERS 1 Pre Infuse Standard 3 gal Brew Total valve time of 319 seconds required for 128 oz of water Init Vlv Time 60 Pulse Delay 30 Pu...

Страница 25: ...4 seconds To calcu late the Pulse Valve time Total Valve Time minus Initial Valve Time divided by 4 pulse cycles Init Vlv Time 63 Pulse Delay 34 Pulse Valve On 64 Total Valve 319 Bypass Delay 20 Bypas...

Страница 26: ...l return to the off mode 1 Software Firmware Revision will be displayed i e MFW275 Rev3 4 Press ON OFF to advance 2 Data revision will be displayed i e Data Rev2 1 Press ON OFF to advance 3 RTC Real T...

Страница 27: ...Probes XXX XXX The left number determines whether the WATER sensing probe is in contact with water A number of 0 or close to 0 means that water is in contact with the probe while a number of 255 or cl...

Страница 28: ...replacing a flat spray disk or old style embossed spray disk with an revised embossed spray disk the back pressure of the spray head will be changed Note the altered flow rates for E Max when the new...

Страница 29: ...me Initial Valve sec Pulse Delay sec Pulse Valve sec Total Valve sec Bypass Delay E Max T Bypass Valve E Max T After Hours 0 to 6 hr QualityTime Timer Weekday ON hr min Weekday OFF hr min Weekend ON h...

Страница 30: ...ION CUSTOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association Commercial Food Equipment Service Association WELLS BLOOMFIELD LLC 2 ERIK CIRCLE P O Box...

Отзывы: