background image

OPERATION 

IMPORTANT: 

All E-Max™ brewers are 
tested and set at the  factory.  
If programming adjust-
ments are necessary,   
refer to the appropriate 
section of this manual. 
 

 
To over-ride the Brew 
Wait mode

, press and 

hold the BREW key for    
3 seconds when the 
brewer is in Brew Wait 
mode (i.e. when brew light 
is flashing).  The brew will 
proceed immediately    
regardless of water     
temperature.  This feature 
should only be used when 
testing water volume,   
otherwise the brew will 
proceed with the water 
below the precise brew 
temperature.  
 
 

Note:   

the following 

safety features have been 
incorporated to prevent 
multiple unattended 
brews: 

 

The brew key is disabled 
during a brew cycle.  This 
minimizes the possibility 
of double   brewing.  

 

When the “Brew” light is 
on or flashing, repeated 
pressing of the BREW 
switch will be ignored, 
(there will be a beep each 
time it is pressed).  A 
Brew will only be activated 
when the “Brew” light is 
off. 

1.

 

Energizing the Brewer:

 When electricity has been connected to 

 

the unit, there will be a momentary flash of the power light.  Turn        

 the brewer on by pressing the POWER key. The 
brewer will start to fill the tank.  With the proper   
water supply the tank should be filled in about 2½ 
minutes.  Once filled, the heating  element will come 
on until the proper tank  temperature has been 
reached, (which will take about 20 minutes on    
120-Volt models or about 12 minutes on 120/240 
Volt models)

 

2.  Brewing (Precise Temperature for Brewing™ — PTB™):

 In the 

 

regular operating mode, the E-Max™ maintains the tank            

temperature /- 1ºF of the brew temperature. 
Normally this will mean that a brew will be started 
as soon as the BREW key is pressed.  However, 
there may be a slight  delay if the BREW key is 
pressed immediately after a brew has been      
completed (notably on 120 volt models).  If the tank 
temperature is below the brew temperature, the 
brew will be delayed, going into the “

Brew Wai

t” 

mode, with the brew light flashing.  As soon as the 
correct temperature is reached the brew will     

commence with the brew light on continuously during the brew.  When 
the brew begins the main warming station will be turned on             
automatically (if it is not already on). During the brew cycle, if the 
BREW key is pressed, it will be ignored.  Only when the brew is       
complete can another brew be started. 
 

3. Brew 

Cancel:

 To cancel a brew in progress, press the CANCEL 

KEY: two beeps will sound and the “Brew” light  
will go out.  Water flowing to the brew chamber  
will be stopped immediately, but if there is 
already water in the brew chamber, it will take a       
few moments before this drips through as 
coffee. 
 
 

 
 

4.  Normal Operation (Non Brewing):

 When the unit is not brewing, 

 

the E-Max™ maintains the water temperature at the Precise 

 

Temperature for Brewing™ (PTB™).   The heating element will   

 

cycle on and off automatically to maintain this temperature. 

 

5.  After Hours Mode:  

If no brew is detected for a pre-selected length 

 

of time, the brewer will enter the After Hours mode.  Temperature 

 

will be allowed to drop to save energy.  Pressing the BREW KEY 

 

returns the brewer to normal operation. 

OPERATING INSTRUCTIONS 

654 p/n 

73674

 E-Max™ 

Prog

ra

mm

ing 

M

a

n

ual 

Содержание E-MAX

Страница 1: ...NV 89439 telephone 888 492 2782 fax 888 492 2783 www wellsbloomfield com p n 73674 Rev I ECN 13315 M654 070718 cps 654 PROGRAMMING MANUAL for E MAX COFFEE AND TEA BREWERS E Max BREWERS are covered un...

Страница 2: ...CALIBRATION 18 PULSE BREW AND PRE INFUSION 19 TEST PROGRAM E MAX 24 ADDENDUM Extract of Service Bulletin 26 xi Thank You for purchasing this Wells Bloomfield appliance Proper installation professional...

Страница 3: ...structions and warnings in the corresponding Service Manual must be read and understood by all operators and users Except as noted this piece of equipment is made in the USA and has American sizes on...

Страница 4: ...gular operating mode the E Max maintains the tank temperature within 1 F of the brew temperature Normally this will mean that a brew will be started as soon as the BREW key is pressed However there ma...

Страница 5: ...the spray head Place one 1 genuine Bloomfield paper filter into the brew chamber Add your choice of pre measured ground coffee Shake the brew chamber gently to level the coffee Slide the brew chamber...

Страница 6: ...Key 6 AIRPOT THERMAL BREWERS TEA BREWERS WITH VOLUME KEY 1 BREW Key 1 2 BREW CANCEL Key 2 3 POWER Key 3 4 STANDARD VOLUME Key 4 5 SMALL VOLUME Key 5 6 LARGE VOLUME Key 6 TEA BREWERS WITHOUT VOLUME KE...

Страница 7: ...e brewer will remain ON until the automatic programmed off time when it will turn OFF and resume normal automatic timed functioning Similarly if turned OFF during the automatic timed ON mode the brewe...

Страница 8: ...rmal operation heating the water to the Precise Temperature for Brewing PTB before starting the brew The power light will be on continuously and the Brew light will flash until the correct water tempe...

Страница 9: ...it will go into the over temperature mode as above with all lights flashing except the LCD will read overheat error and Call for Service To reset press and hold the 2nd key for 3 seconds or re energi...

Страница 10: ...brewers and on Tea brewers with volume keys the 4th key is STANDARD Volume and the 6th key is Large Volume On Tea brewers without volume keys the 4th key is hidden under the E and the 6th key is hidd...

Страница 11: ...then press 3rd key ON OFF ITEM to get to the required ITEM 3 To Increase Decrease or Change settings when in the programming mode press the 5th or 6th keys Suggestion If the key is pressed and held t...

Страница 12: ...10 PROGRAMMING TABLE 654 p n 73674 E Max Programming Manual...

Страница 13: ...11 PROGRAMMING TABLE continued 654 p n 73674 E Max Programming Manual...

Страница 14: ...Vol 1 This number will be displayed on the LCD when volumes are being changed Pulse Brew To access the pulse or pre infusion programs terminate Brew Vol with the 4th key See Pulse Brew details outline...

Страница 15: ...6th keys Decanter Brewers If the Quality Timer is activated each warmer plate will count down from the programmed time when the warmer plate is turned on Once the count down time is reached the appro...

Страница 16: ...n the keypad switches can only be activated by pressing and holding the CANCEL key for 6 seconds Then the keypad will be active until a brew has been completed Or if a brew is not started the keypad w...

Страница 17: ...e re loaded value if defaults are loaded Re loading of defaults should be used only if major programming problems have occurred and it is necessary to return to factory settings 15 MAX WATER LOCATION...

Страница 18: ...Calibration is on the screen The probe is factory set and should not need resetting unless the control ler board or probe is changed See Calibration Instructions following the Factory Settings menu it...

Страница 19: ...ce empty decanter or other vessel under the faucet and begin drawing water from the faucet 6 When the inlet valve comes on stop drawing water from the faucet and count the number of seconds before the...

Страница 20: ...out the level sensor Insert the thermometer into the brewer Allow time for the thermometer temperature to stablize 5 Once the actual tank temperature has been established look at the values on the scr...

Страница 21: ...the water over a longer period of time thus preventing any overflow problems 1 Select the Brew Volume that will be using the pulse brew feature i e go to selected volume BrewVol1 2 3 or 4 in the Brew...

Страница 22: ...is required this will also be calculated automatically The outflow rate of water from the spray head is required to calculate valve time for different volumes Spray head outflow rates are based on th...

Страница 23: ...ucing 3 pulse cycles each with a 20 second delay Init Vlv Time 10 Pulse Delay 20 Pulse Valve On 54 Total Valve 172 21 1 PRE INFUSION ON ON OFF 30 sec 20 sec 152 sec OFF DRIP OUT 60 sec One Pulse Cycle...

Страница 24: ...36 Pulse Valve On 58 Total Valve 236 Pulse Feature Examples TEA BREWERS 1 Pre Infuse Standard 3 gal Brew Total valve time of 319 seconds required for 128 oz of water Init Vlv Time 60 Pulse Delay 30 Pu...

Страница 25: ...4 seconds To calcu late the Pulse Valve time Total Valve Time minus Initial Valve Time divided by 4 pulse cycles Init Vlv Time 63 Pulse Delay 34 Pulse Valve On 64 Total Valve 319 Bypass Delay 20 Bypas...

Страница 26: ...l return to the off mode 1 Software Firmware Revision will be displayed i e MFW275 Rev3 4 Press ON OFF to advance 2 Data revision will be displayed i e Data Rev2 1 Press ON OFF to advance 3 RTC Real T...

Страница 27: ...Probes XXX XXX The left number determines whether the WATER sensing probe is in contact with water A number of 0 or close to 0 means that water is in contact with the probe while a number of 255 or cl...

Страница 28: ...replacing a flat spray disk or old style embossed spray disk with an revised embossed spray disk the back pressure of the spray head will be changed Note the altered flow rates for E Max when the new...

Страница 29: ...me Initial Valve sec Pulse Delay sec Pulse Valve sec Total Valve sec Bypass Delay E Max T Bypass Valve E Max T After Hours 0 to 6 hr QualityTime Timer Weekday ON hr min Weekday OFF hr min Weekend ON h...

Страница 30: ...ION CUSTOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association Commercial Food Equipment Service Association WELLS BLOOMFIELD LLC 2 ERIK CIRCLE P O Box...