background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE: 
If water is not sensed at the 
water level sensor within 20 
minutes: 
     Heater will be disabled 
     Error message NO WATER      
     SENSED will be displayed 
 
Call the PHONE NUMBER 
displayed for service. 

GETTING STARTED 

 

Check the brewer and satellites: 

 

       Check that the brewer is clean and the drip tray (if used)  
       is empty. 

 

       Check that the satellites are empty and clean with lids 
       properly installed. 
 
Check the spray heads: 

 

       Remove the brew chambers.  Check the spray heads.  Verify 
       that the spray disks are clean and properly installed.  Verify 
       that the gaskets are properly installed inside the spray heads. 
 
Check the brew chambers: 

 

       Check that the brew chamber is clean. 

 

       Check that the wire basket is properly installed in the  
       brew chamber. 

 
DAILY START-UP 

 

Press system switch (back of brewer, lower right corner) to ON: 

 

       Brewer will “beep” and briefly display the message 
       BLOOMFIELD. 
 
Press POWER KEY to enter 

ON

  mode: 

 

       Brewer water tank will begin filling.  The message FILLING 
       will be displayed. 

 

       When the tank is full, TANK HEAT LED will glow, and the 
       message HEATING is displayed indicating that  the tank  
       heater is 

ON

 

Press WARMER SWITCHES to 

OFF

 until you are ready to begin 

a brew. 
 
When the tank is filled and up to temperature, time and date are 
displayed.  The brewer is ready to operate. 

OPERATING INSTRUCTIONS 

Fig. 3  Control Panel 

Содержание 9421 (SS2-HE)

Страница 1: ...569 www wellsbloomfield com p n 74340 Rev C M673 040402 cps 673 OWNERS MANUAL for SS2 SERIES DUAL SATELLITE COFFEE BREWERS with ELECTRONIC PROGRAMMABLE CONTROL and EXTERNALLY HEATED SATELLITE SERVERS...

Страница 2: ...f its sub agencies This service will be provided on customer s premises for non portable models Portable models a device with a cord and plug must be taken or shipped to the closest Authorized Service...

Страница 3: ...d maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 4 AGENCY A...

Страница 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 SS 2 Satellite Brewing System Features Operating Controls...

Страница 5: ...dispensed here Lists manufacturer model and serial number Also lists voltage and wattage rating of brewer Controls brewer ON MODE and OFF MODE Located on lower right rear of brewer Turns main power to...

Страница 6: ...r wiring Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instru...

Страница 7: ...ss than 3 8 copper tubing for installations exceeding 12 Brewer should be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must be installed...

Страница 8: ...applied to the brewer the display will read BLOOMFIELD briefly and a beep will sound Press the POWER key The inlet valve will energize and the tank will begin filling The display will read Filling Fil...

Страница 9: ...ly installed inside the spray heads Check the brew chambers Check that the brew chamber is clean Check that the wire basket is properly installed in the brew chamber DAILY START UP Press system switch...

Страница 10: ...brew head Insert Satellites Slide one satellite under each brew chamber until it is fully seated Press appropriate WARMER SWITCH to ON SATELLITE LED for left or right side will glow Select Brew Volume...

Страница 11: ...ee from the brew water tube and is controlled by a signal from the CONTROL BOARD The bypass valve is opened for a length of time as determined from programmed values The bypass valve discharges throug...

Страница 12: ...ve and empty brew baskets 4 Remove spray disks and gaskets from spray heads 5 Wipe inside of spray head and area around spray head with a soft clean cloth or sponge moistened with clean water 6 Wash s...

Страница 13: ...rd Then pull ears forward Lift guard off of retaining clip b Remove sight glass tube from silicone elbow Run the sight glass brush through the tube at least ten times c Reassemble the tube to the sili...

Страница 14: ...key Clock Settings Press POWER key to enter ON mode Press 3rd 4th keys at the same time Check Tank Temperature Press POWER key to enter ON mode Press 3rd 6th keys at the same time NOTE Time is held in...

Страница 15: ...d immediately after a brew has been completed notably on 120v models If the tank temperature is below the brew temperature the brew will be delayed going into the Brew Wait mode with the brew light fl...

Страница 16: ...e automatic timer turned off To set the automatic timer refer to Time Functions Menu If the Automatic Timer feature is programmed off the brewer can be turned on and off by pressing the POWER key as n...

Страница 17: ...ead no volume prog i e no volume programmed 9 Clock Time Battery Backup The Satellite Brewer has a battery backup system which will maintain the proper time during power failures or when the brewer is...

Страница 18: ...s If a particular brew volume has utilized the pulse or pre infusion option that volume will be displayed with an asterisk after the volume As an example Volume 2 would indicate that the second progra...

Страница 19: ...Heats slow Connected to wrong voltage Verify supply voltage Scale build up on heating elements De lime hot water tank Damaged heating element Replace element Slow to fill Insufficient water pressure B...

Страница 20: ...op panel then remove the tank lid assembly Do not disconnect the tank assembly at this time 3 Siphon all water from the hot water tank 4 Mix 10 gallons of deliming solution according to the manufactur...

Страница 21: ...spray disks 13 Reconnect brewer to electrical supply 14 Install the brew chamber without filter paper or grounds 15 Place an empty satellite under the brew chamber Run at least five 1 1 2 gallon brew...

Страница 22: ...EXPLODED VIEW CABINET AND EXTERIOR COMPONENTS 20...

Страница 23: ...21...

Страница 24: ...EXPLODED VIEW INTERIOR COMPONENTS 22 26 32 38 39 36 33 3 41 1 14 30 29 21 19 16 17 47 18 5 8 6 7 37 42 43 45 31 3 9 15 40 48 49 30 34 46 10 34 50 13 4 27 3 28 24 22 44 12 25 27 20 35 11 2 23 29...

Страница 25: ...A 2 23 83319 PLUG TANK LID 298 DIA 1 24 83320 PLUG TANK LID 687 DIA 1 25 83325 TANK LID ASSY 1 26 84336 TUBE TANK TO TEE 2 0 2 27 8043 11 ELBOW OUTLET 2 28 83384 TUBE VENT EXTENSION 2 29 83537 TUBE SI...

Страница 26: ...24 WIRING DIAGRAM...

Страница 27: ...4390 FAUCET MODEL ES 1 4 2 8700 25L SEAT CUP 3S10 1 4 3 84392 HANDLE 13SBE SNAP 1 4 4 84394 C RING 18 1 1 4 5 8600 26 NUT HEX 1 4 6 84395 SHANK 1 5 84299 HOUSING SIGHT GAUGE 1 6 84300 BRACKET SIGHT GA...

Страница 28: ...Telephone 775 345 0444 Service 888 492 2782 website www wellsbloomfield com 5850 Keaton Cresent Mississauga Ontario Canada L5R 3K2 Telephone 905 507 1700 Fax 905 507 1777 Toll Free 877 507 1700 websi...

Отзывы: