Bloomfield 9421 (SS2-HE) Скачать руководство пользователя страница 15

PROGRAMMING INSTRUCTIONS (continued) 

13 

 
 
 
 
 
 
 
 
 
 
 

PRECISE BREWING 
TEMPERATURE™: 
 
The brew cycle will not start   
until the water in the tank is at 
the proper temperature. 
 
If START BREW key is pressed 
and held for 3 seconds during 

Brew Wait

” the brew will  

proceed immediately.

 

 
 
 

Note:   the following safety 
features prevent multiple    
unattended brews: 
 

When the BREW LED is on or 
flashing, repeated pressing of 
the START BREW switch will be 
ignored, (there will be a beep 
each time it is pressed). 
 
A Brew will only be activated or 
put in Brew Wait when the 
BREW LED is off. 
 
Only one brew can be stored in 
“Brew Wait” at a time.  

FEATURES 

 
1.

   

Energizing the Brewer:

   Turn the brewer on by pressing the 

POWER

 key. The brewer will start to fill the tank with the 

message on the screen “

filling…

”.  With the proper water 

supply the tank should be filled in about 2½ minutes.  Once 
filled, the heating element will come on until the proper tank 
temperature has been reached, (which will take about 20 
minutes on 120-Volt models or about 12 minutes on 120/240 
Volt models)

    
2.    Brewing (Precise Temperature Brewing™ — PTB™)

: In 

regular operating mode, the Satellite Brewer maintains the 
tank temperature /- 1ºF of the brew temperature.  
Normally this will mean that a brew will be started as soon as 
the BREW switch is depressed.  However, there may be a 
slight delay if the BREW switch is depressed immediately  
after a brew has been completed (notably on 120v models).  
If the tank temperature is below the brew temperature, the 
brew will be delayed going into the “Brew Wait” mode, with 
the brew light flashing, and the message on the screen 

heating…

”.  As soon as the correct temperature is reached 

the brew will commence with the BREW LED on continuously 
during the brew.  The time remaining in the brew will count 
down on the display.  During the brew if the BREW switch is 
depressed, it will be ignored.  Only if the brew is complete 
can another brew be started.  

 

    

       To over-ride the Brew Wait Mode

, press and hold the 

START BREW key for 3 seconds when the brewer is in Brew 
Wait mode (i.e. when BREW LED is flashing).  The brew will 
proceed immediately regardless of water temperature.  This 
feature should only be used when testing water volume,    
otherwise the brew will proceed with the water below the  
precise brew temperature.  

 

3.    Brew Cancel:

  To cancel a brew in progress, or to cancel a 

       brew waiting, depress the STOP BREW key: two beeps will 
       sound and the BREW LED will go out.  Water flowing to the 
       brew basket will be stopped immediately, but, if there is     
       already water in the brew basket, it will take a few moments         
       before this drips through as coffee 

 

4.  Normal Operation (Non Brewing):

   When the unit is not 

brewing, the Brewer maintains the water temperature at the 
Precise Temperature for Brewing™ (PTB™).   The heating 
element will cycle on and off automatically to maintain this 
temperature.  The TANK HEAT LED will glow any time the 
heating element is energized. 

             

 

Содержание 9421 (SS2-HE)

Страница 1: ...569 www wellsbloomfield com p n 74340 Rev C M673 040402 cps 673 OWNERS MANUAL for SS2 SERIES DUAL SATELLITE COFFEE BREWERS with ELECTRONIC PROGRAMMABLE CONTROL and EXTERNALLY HEATED SATELLITE SERVERS...

Страница 2: ...f its sub agencies This service will be provided on customer s premises for non portable models Portable models a device with a cord and plug must be taken or shipped to the closest Authorized Service...

Страница 3: ...d maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 4 AGENCY A...

Страница 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 SS 2 Satellite Brewing System Features Operating Controls...

Страница 5: ...dispensed here Lists manufacturer model and serial number Also lists voltage and wattage rating of brewer Controls brewer ON MODE and OFF MODE Located on lower right rear of brewer Turns main power to...

Страница 6: ...r wiring Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instru...

Страница 7: ...ss than 3 8 copper tubing for installations exceeding 12 Brewer should be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must be installed...

Страница 8: ...applied to the brewer the display will read BLOOMFIELD briefly and a beep will sound Press the POWER key The inlet valve will energize and the tank will begin filling The display will read Filling Fil...

Страница 9: ...ly installed inside the spray heads Check the brew chambers Check that the brew chamber is clean Check that the wire basket is properly installed in the brew chamber DAILY START UP Press system switch...

Страница 10: ...brew head Insert Satellites Slide one satellite under each brew chamber until it is fully seated Press appropriate WARMER SWITCH to ON SATELLITE LED for left or right side will glow Select Brew Volume...

Страница 11: ...ee from the brew water tube and is controlled by a signal from the CONTROL BOARD The bypass valve is opened for a length of time as determined from programmed values The bypass valve discharges throug...

Страница 12: ...ve and empty brew baskets 4 Remove spray disks and gaskets from spray heads 5 Wipe inside of spray head and area around spray head with a soft clean cloth or sponge moistened with clean water 6 Wash s...

Страница 13: ...rd Then pull ears forward Lift guard off of retaining clip b Remove sight glass tube from silicone elbow Run the sight glass brush through the tube at least ten times c Reassemble the tube to the sili...

Страница 14: ...key Clock Settings Press POWER key to enter ON mode Press 3rd 4th keys at the same time Check Tank Temperature Press POWER key to enter ON mode Press 3rd 6th keys at the same time NOTE Time is held in...

Страница 15: ...d immediately after a brew has been completed notably on 120v models If the tank temperature is below the brew temperature the brew will be delayed going into the Brew Wait mode with the brew light fl...

Страница 16: ...e automatic timer turned off To set the automatic timer refer to Time Functions Menu If the Automatic Timer feature is programmed off the brewer can be turned on and off by pressing the POWER key as n...

Страница 17: ...ead no volume prog i e no volume programmed 9 Clock Time Battery Backup The Satellite Brewer has a battery backup system which will maintain the proper time during power failures or when the brewer is...

Страница 18: ...s If a particular brew volume has utilized the pulse or pre infusion option that volume will be displayed with an asterisk after the volume As an example Volume 2 would indicate that the second progra...

Страница 19: ...Heats slow Connected to wrong voltage Verify supply voltage Scale build up on heating elements De lime hot water tank Damaged heating element Replace element Slow to fill Insufficient water pressure B...

Страница 20: ...op panel then remove the tank lid assembly Do not disconnect the tank assembly at this time 3 Siphon all water from the hot water tank 4 Mix 10 gallons of deliming solution according to the manufactur...

Страница 21: ...spray disks 13 Reconnect brewer to electrical supply 14 Install the brew chamber without filter paper or grounds 15 Place an empty satellite under the brew chamber Run at least five 1 1 2 gallon brew...

Страница 22: ...EXPLODED VIEW CABINET AND EXTERIOR COMPONENTS 20...

Страница 23: ...21...

Страница 24: ...EXPLODED VIEW INTERIOR COMPONENTS 22 26 32 38 39 36 33 3 41 1 14 30 29 21 19 16 17 47 18 5 8 6 7 37 42 43 45 31 3 9 15 40 48 49 30 34 46 10 34 50 13 4 27 3 28 24 22 44 12 25 27 20 35 11 2 23 29...

Страница 25: ...A 2 23 83319 PLUG TANK LID 298 DIA 1 24 83320 PLUG TANK LID 687 DIA 1 25 83325 TANK LID ASSY 1 26 84336 TUBE TANK TO TEE 2 0 2 27 8043 11 ELBOW OUTLET 2 28 83384 TUBE VENT EXTENSION 2 29 83537 TUBE SI...

Страница 26: ...24 WIRING DIAGRAM...

Страница 27: ...4390 FAUCET MODEL ES 1 4 2 8700 25L SEAT CUP 3S10 1 4 3 84392 HANDLE 13SBE SNAP 1 4 4 84394 C RING 18 1 1 4 5 8600 26 NUT HEX 1 4 6 84395 SHANK 1 5 84299 HOUSING SIGHT GAUGE 1 6 84300 BRACKET SIGHT GA...

Страница 28: ...Telephone 775 345 0444 Service 888 492 2782 website www wellsbloomfield com 5850 Keaton Cresent Mississauga Ontario Canada L5R 3K2 Telephone 905 507 1700 Fax 905 507 1777 Toll Free 877 507 1700 websi...