OPERATION
Fig. 4 Brewer Operation Diagram
START-UP
For initial start-up, or if the brewer has not been used for an
extended period of time:
• Be sure spray disk and brew gasket are properly installed in the
brew head.
• Be sure the water supply is properly connected and the water sup-
ply valve is turned ON.
• Be sure faucet water tank drain cap is securely installed.
• Be sure the WATER TANKS ARE FILLED.
IMPORTANT:
Fill the water tanks before pressing heater switches
ON
:
1. Insert the brew chamber (empty) and place an empty decanter in
place under the brew chamber. Be sure heater switches are OFF.
2. Press main power switch ON.
3. Press “BREW” button and allow brew cycle to complete. Repeat
until water flows from the brew head. If SERVICE FAUCET TANK
lights, press main power switch OFF, then ON to reset.
4. Place an empty container under the hot water faucet. Hold the
faucet open until water flows and all air is purged.
5. Press the tank heater switches ON. The heating elements will
begin heating the water in the tanks. When the water in a tank has
reached the proper temperature, the associated “READY” light will
glow.
A.
IMPORTANT:
Tanks must be full of
water before pressing
either TANK HEATER
SWITCH “
on
”. Heating
elements will be dam-
aged if allowed to oper-
ate without being fully
submerged in water.
Damage caused by
operating the brewer
without water in the tank
is
NOT COVERED BY
WARRANTY
.
If no water is detected at
water level probe after
two minutes, unit will shut
down and the SERVICE
FAUCET TANK light will
glow.
6
915 2M-Z15131 Owners Manual for 8783MCD
IL2326
Содержание 8783D3FM
Страница 21: ...915 2M Z15131 Owners Manual for 8783MCD WIRING DIAGRAM 19...
Страница 22: ...NOTES 915 2M Z15131 Owners Manual for 8783MCD 20...
Страница 23: ...915 2M Z15131 Owners Manual for 8783MCD NOTES 21...
Страница 24: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www wellsbloomfield com...