background image

SERVICING INSTRUCTIONS (continued)

10. Reinstall tank lid assembly into hot water tank.  Make sure  

the lid gasket is properly in place, then reinstall the 

 

hold-down clamps.

11.  Remove spray disks and gaskets.  Rinse both brew heads  

with clean water.  Using a stiff brush, scrub spray disk to  

remove any lime or calcium build-up.  Reinstall gaskets  

and spray disks.

13. Reconnect brewer to electrical supply .
14. Install the brew chamber without filter paper or grounds. 
15. Place an empty server under the brew chamber.   Run at  

least five 1-1/2 gallon brew cycles and  discard all water  

generated at the end of each cycle.

 

Repeat for the other side.

16. Rinse server with clean water.  Reinstall one empty       

satellite under each brew chamber.

Brewer is ready to use.

DRAINING HOT WATER TANK

1.  Disconnect brewer from the electrical supply
2.  Remove the top panel assembly (4 Screws)
3.  Remove the front panel assyembly (4 Screws)
4.  Release the drain hose & hose clamp assy from the retaining 

clip.

5.  Bring the drain hose down out the front panel so its lower 

than the tank.

6.  Remove the red hose cap.
6.  Open the hose clamp and drain into container.

CAUTION: 

Tank holds 6 gallons of water and can may contain 

HOT WATER, 

7.  When tank is empty, close the hose clamp and place the red 

cap back into position.

8.  Place the end of the hose back into its retaining clip.

NOTE: 

 Normally, silicone 

hoses do not need to be 

delimed.  Should deliming hoses 

become necessary, Bloomfield 

recommends replacing the 

hoses.

IMPORTANT:

  DO NOT allow 

any internal components to 

come into contact with the any 

deliming solution.  Take care to 

keep all internal components 

dry.

13

655   2M-Z17970 Owners Manual E-Maxl Thermal Brewer

Содержание 2795TF

Страница 1: ...orldwide com p n 2M Z17970 Rev A M655 140422 655 OWNERS MANUAL for 2795TF SERIES THERMAL COFFEE BREWER with E Max CONTROL MODEL 2795TF Includes Installation Operation Use Care Servicing Instructions E...

Страница 2: ...f thermostats microswitches and replacement of fuses and indicating lights are not covered under warranty 5 All problems due to inadequate water supply such as fluctuating or high or low water pressur...

Страница 3: ...he appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 GENERAL INFORMATION PRECAUTIONS 4 AGENCY APPROVAL INFORMATION 4...

Страница 4: ...THERMAL SERVER HOT WATER DRIP TRAY 6th KEY LARGE VOLUME 5th KEY SMALL VOLUME 4th KEY STANDARD VOLUME 1st KEY START BREW LED INDICATORS VIEW SCREEN CONTROL PANEL BREW HEAD BREW CHAMBER REMOVED 2nd KEY...

Страница 5: ...ber Also lists voltage and wattage rating of brewer Glows when the tank water is up to temperature Located on lower right rear of brewer Turns main power to brewer ON or OFF Holds coffee grounds durin...

Страница 6: ...procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagra...

Страница 7: ...less and not less than 3 8 copper tubing for installations exceeding 12 Brewer must be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must...

Страница 8: ...ng mode the E Max T maintains the tank temperature within 1 F of the brew temperature Normally this will mean that a brew will be started as soon as the BREW key is pressed However there may be a slig...

Страница 9: ...your choice of pre measured tea leaves Shake the brew chamber gently to level the tea leaves Slide the brew chamber back into place 2 Place an empty dispenser under the brew chamber 3 If any volume ot...

Страница 10: ...n the automatic timed OFF mode the brewer can be started by depressing the ON OFF switch The brewer will remain ON until the automatic programmed off time when it will turn OFF and resume normal autom...

Страница 11: ...quently this feature saves energy and extend component life While in the After Hours mode the power light will flash continuously When the BREW switch is pressed the E Max T automatically reverts back...

Страница 12: ...mperature set in the program factory set at 208 F or 98 C it will go into the over temperature mode as above with all lights flashing except the LCD will read overheat error and Call for Service To re...

Страница 13: ...through the brew basket but is diverted from the grounds by a bypass channel The remainder of the water is discharged through the BREW HEAD and flows over the grounds in the brew basket at a PRESET o...

Страница 14: ...A bristle brush may be used to clean around the bypass diverters Rinse with clean water and allow to air dry Be sure bypass diverters are properly installed 8 Wipe exterior of brewer and servers with...

Страница 15: ...urfaces with dry cloth 6 Reinstall funnel assembly lids drip tray Install satellites on brewer 7 Rinse servers with an empty brew chamber in place press the BREW key and run 1 full cycle into each ser...

Страница 16: ...Do not disconnect the tank assembly at this time 3 Drain all water from the hot water tank see DRAINING HOT WATER TANK procedures 4 Mix 10 gallons of deliming solution according to the manufacturer s...

Страница 17: ...eady to use DRAINING HOT WATER TANK 1 Disconnect brewer from the electrical supply 2 Remove the top panel assembly 4 Screws 3 Remove the front panel assyembly 4 Screws 4 Release the drain hose hose cl...

Страница 18: ...lid assembly in a safe location 4 Mix de liming solution according to the manufacturer s directions Add the de liming solution to the water tank Set lid assembly back on tank Allow to sit for 30 minu...

Страница 19: ...the brewer cools then functions normally 5 Heating element may be encrusted with lime or scale build up DELIME BREWER AS DETAILED ON PAGE 16 2 Overheat Error RESET by holding CANCEL switch for 3 secon...

Страница 20: ...y pressing the BREW key Y u will hear a beep and the display will change to Test Switch 2 2 Test 2nd key by pressing the CANCEL key You will hear a beep and the display will change to Test Switch 3 3...

Страница 21: ...tput 1 Inlet Output 2 Dump Output 3 Heater Output 4 Bypass Output 5 Future not functional at this time Output 6 Future not functional at this time 3 Each component should turn ON in order with only on...

Страница 22: ...TF E Max Thermal Brewer 1 2 3 4 5 8 9 10 30 11 12 13 14 16 17 18 20 24 25 1 27 28 29 26 1 SEE DETAIL A 21 22 23 19 15 6 3 7 EXPLODED VIEW 2795TF CABINET AND EXTERIOR COMPONENTS 18 655 2M Z17970 Owners...

Страница 23: ...I 72215 1 GASKET SPRAY HEAD 1 5 ID 13 A6 72727 1 SPRAY HEAD DISC EMBOSSED 14 D7 76652 1 CHAMBER BREW ASSY 15 D7 Z16812 1 BRKT BYPASS PLASTIC BREW 16 2U 71061 1 FAUCET HOT WATER 17 2E 37465 1 TERM BLOC...

Страница 24: ...W 2795TF INTERIOR COMPONENTS 20 655 2M Z17970 Owners Manual E Maxl Thermal Brewer SK2732 Rev 12 23 13 Model 2795TF E Max Thermal Brewer Tank Assy 7 13 14 17 18 19 20 21 22 16 15 6 1 2 3 4 5 8 11 12 9...

Страница 25: ...FILL 90 DEGREE 8 2I 72390 1 GROMMET 375 ID TRANSLUCE 9 2K 70103 2 ELBOW OUTLET 10 2A 73384 3 TUBE SPRAY HEAD 2 3 8 LG 11 A6 73521 1 PROBE ASSY WATER LEVEL 12 2A 73532 1 SLEEVE WATER LEVEL PROBE 13 2I...

Страница 26: ...OT 3 DUMP LINE 2 INLET LINE 1 HEATER LINE 3 WP1 2 WP2 1 WP3 1 2 3 4 HI LIMIT THERMOSTAT HI LIMIT THERMOSTAT TRIAC WARMER SWITCH 2121 ONLY WARMER ELEMENT 2121 ONLY HEATING ELEMENT LEFT 120V 1500W HEATI...

Страница 27: ...27 655 2M Z17970 Owners Manual E Maxl Thermal Brewer NOTES...

Страница 28: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www bloomfieldworldwide com...

Отзывы: