655   2M-Z17970 Owners Manual E-Maxl Thermal Brewer

655   2M-Z17970 Owners Manual E-Maxl Thermal Brewer

OPERATING (continued)

8. Clock

A.  Time – Battery Backup. 

 The E-Max T has a battery backup system which will maintain the proper 

time during power failures, or when the brewer is unplugged (even for very prolonged periods of time).  

Normally there will not be a need to set the time except for Daylight Saving  Time changes, or moving the 

brewer to different time zones.

B.  Changing Day and Time:

  To change time, turn the E-Max T off.  Press the 2nd key twice followed by 

the 1st key twice to access the time change mode, (i.e. press CANCEL, CANCEL, BREW, BREW).  In 

the time change mode the screen will read “Day:” followed by the current day setting.  Use the 6th key 

to advance the day, or the 5th key to reverse.  When day has been properly set, press the 3rd key.  The 

screen will now read “Time:” with the set time on the screen, the hour and am or pm flashing.  Use the 

5th key to go back or the 6th key to advance the hour, making sure that the am or pm is correct.  When 

the hour and am/pm is correctly set, press the 3rd key, and the screen will read “Time:” with the set time 

on the screen, minutes flashing.  As previously use the 5th or 6th keys to adjust the minutes, and press 

the 3rd key when complete.  E-Max T will return to the off mode.  (Changing time can also be done in the 

regular programming mode.  Consult the E-Max 

Programming Manual

)

C.  After Hours:  Consult the  E-Max Programming Manual to set the After Hours mode.  The factory 

programming has the After Hours mode turned OFF. The After Hours can be programmed to come on 

from 1 to 6 hours after the last brew.  When the E-Max T goes into the After Hours mode, the water in the 

tank will be allowed to drop from the normal brewing temperature and will reheat less frequently – this 

feature saves energy and extend component life.  While in the After Hours mode, the power light will 

flash continuously.  When the BREW switch is pressed the E-Max T automatically reverts back to normal 

operation, heating the water to the Precise Temperature for Brewing (PTB), before starting the brew.  

(The power light will be on continuously and the Brew light will flash until the correct water temperature is 

reached.)

9.  Countdown Quality Timer:

  Refers to coffee warmers, not applicable for Thermal Brewers.

10. Pulse or Pre-Infusion Volume Options: 

 

To set these features, refer to E-Max 

Programming Manual, Brew Settings Menu.  If 

a particular brew volume has utilized the pulse 

or pre-infusion option, that volume will be 

displayed with an asterisk (*) after the volume.  

 

As an example 

“Volume#2 3 G*”

 would 

indicate that the second programmed brew 

volume has utilized the pulse or pre-infusion 

program options.

11.  Keypadlock:

  This feature is OFF in the 

standard factory settings.  To set the feature 

refer to E-Max Programming Manual, Machine 

Settings Menu.  If the Keypadlock feature is 

activated, there will be no response by the 

brewer when the keys are depressed (except 

for the beep after a key is depressed).  To 

temporarily “unlock” the keypad, press and 

hold the CANCEL key for 6 seconds.  A beep 

will be heard indicating the keypad is now 

“unlocked”, — a brew can be initiated, warmer plates turned on or off, etc.  The keypad will remain 

unlocked until the brew is completed, then automatically return to keypadlock mode.  If a brew is not 

initiated 60 seconds after  “unlocking”, the system will time out and return to the “locked” position.

DEFAULT PROGRAMS

Type: Satellite

Position

1 Gal

1/2 Gal

1-1/2 Gal

Total Valve

215

142

322

Press 4th Key

Init. Valve Time

30

Pulse Delay

5

Pulse Valve On

10

25

Bypass Tiem

150

20

200

Brew Complete

45

30

60

Approximate Flow Rates

To determine brew time for a volume divide ounces by flow rate:

Brew Valve:  .50oz sec
Bypass Valve .27oz sec

Содержание 2795TF

Страница 1: ...orldwide com p n 2M Z17970 Rev A M655 140422 655 OWNERS MANUAL for 2795TF SERIES THERMAL COFFEE BREWER with E Max CONTROL MODEL 2795TF Includes Installation Operation Use Care Servicing Instructions E...

Страница 2: ...f thermostats microswitches and replacement of fuses and indicating lights are not covered under warranty 5 All problems due to inadequate water supply such as fluctuating or high or low water pressur...

Страница 3: ...he appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 GENERAL INFORMATION PRECAUTIONS 4 AGENCY APPROVAL INFORMATION 4...

Страница 4: ...THERMAL SERVER HOT WATER DRIP TRAY 6th KEY LARGE VOLUME 5th KEY SMALL VOLUME 4th KEY STANDARD VOLUME 1st KEY START BREW LED INDICATORS VIEW SCREEN CONTROL PANEL BREW HEAD BREW CHAMBER REMOVED 2nd KEY...

Страница 5: ...ber Also lists voltage and wattage rating of brewer Glows when the tank water is up to temperature Located on lower right rear of brewer Turns main power to brewer ON or OFF Holds coffee grounds durin...

Страница 6: ...procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagra...

Страница 7: ...less and not less than 3 8 copper tubing for installations exceeding 12 Brewer must be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must...

Страница 8: ...ng mode the E Max T maintains the tank temperature within 1 F of the brew temperature Normally this will mean that a brew will be started as soon as the BREW key is pressed However there may be a slig...

Страница 9: ...your choice of pre measured tea leaves Shake the brew chamber gently to level the tea leaves Slide the brew chamber back into place 2 Place an empty dispenser under the brew chamber 3 If any volume ot...

Страница 10: ...n the automatic timed OFF mode the brewer can be started by depressing the ON OFF switch The brewer will remain ON until the automatic programmed off time when it will turn OFF and resume normal autom...

Страница 11: ...quently this feature saves energy and extend component life While in the After Hours mode the power light will flash continuously When the BREW switch is pressed the E Max T automatically reverts back...

Страница 12: ...mperature set in the program factory set at 208 F or 98 C it will go into the over temperature mode as above with all lights flashing except the LCD will read overheat error and Call for Service To re...

Страница 13: ...through the brew basket but is diverted from the grounds by a bypass channel The remainder of the water is discharged through the BREW HEAD and flows over the grounds in the brew basket at a PRESET o...

Страница 14: ...A bristle brush may be used to clean around the bypass diverters Rinse with clean water and allow to air dry Be sure bypass diverters are properly installed 8 Wipe exterior of brewer and servers with...

Страница 15: ...urfaces with dry cloth 6 Reinstall funnel assembly lids drip tray Install satellites on brewer 7 Rinse servers with an empty brew chamber in place press the BREW key and run 1 full cycle into each ser...

Страница 16: ...Do not disconnect the tank assembly at this time 3 Drain all water from the hot water tank see DRAINING HOT WATER TANK procedures 4 Mix 10 gallons of deliming solution according to the manufacturer s...

Страница 17: ...eady to use DRAINING HOT WATER TANK 1 Disconnect brewer from the electrical supply 2 Remove the top panel assembly 4 Screws 3 Remove the front panel assyembly 4 Screws 4 Release the drain hose hose cl...

Страница 18: ...lid assembly in a safe location 4 Mix de liming solution according to the manufacturer s directions Add the de liming solution to the water tank Set lid assembly back on tank Allow to sit for 30 minu...

Страница 19: ...the brewer cools then functions normally 5 Heating element may be encrusted with lime or scale build up DELIME BREWER AS DETAILED ON PAGE 16 2 Overheat Error RESET by holding CANCEL switch for 3 secon...

Страница 20: ...y pressing the BREW key Y u will hear a beep and the display will change to Test Switch 2 2 Test 2nd key by pressing the CANCEL key You will hear a beep and the display will change to Test Switch 3 3...

Страница 21: ...tput 1 Inlet Output 2 Dump Output 3 Heater Output 4 Bypass Output 5 Future not functional at this time Output 6 Future not functional at this time 3 Each component should turn ON in order with only on...

Страница 22: ...TF E Max Thermal Brewer 1 2 3 4 5 8 9 10 30 11 12 13 14 16 17 18 20 24 25 1 27 28 29 26 1 SEE DETAIL A 21 22 23 19 15 6 3 7 EXPLODED VIEW 2795TF CABINET AND EXTERIOR COMPONENTS 18 655 2M Z17970 Owners...

Страница 23: ...I 72215 1 GASKET SPRAY HEAD 1 5 ID 13 A6 72727 1 SPRAY HEAD DISC EMBOSSED 14 D7 76652 1 CHAMBER BREW ASSY 15 D7 Z16812 1 BRKT BYPASS PLASTIC BREW 16 2U 71061 1 FAUCET HOT WATER 17 2E 37465 1 TERM BLOC...

Страница 24: ...W 2795TF INTERIOR COMPONENTS 20 655 2M Z17970 Owners Manual E Maxl Thermal Brewer SK2732 Rev 12 23 13 Model 2795TF E Max Thermal Brewer Tank Assy 7 13 14 17 18 19 20 21 22 16 15 6 1 2 3 4 5 8 11 12 9...

Страница 25: ...FILL 90 DEGREE 8 2I 72390 1 GROMMET 375 ID TRANSLUCE 9 2K 70103 2 ELBOW OUTLET 10 2A 73384 3 TUBE SPRAY HEAD 2 3 8 LG 11 A6 73521 1 PROBE ASSY WATER LEVEL 12 2A 73532 1 SLEEVE WATER LEVEL PROBE 13 2I...

Страница 26: ...OT 3 DUMP LINE 2 INLET LINE 1 HEATER LINE 3 WP1 2 WP2 1 WP3 1 2 3 4 HI LIMIT THERMOSTAT HI LIMIT THERMOSTAT TRIAC WARMER SWITCH 2121 ONLY WARMER ELEMENT 2121 ONLY HEATING ELEMENT LEFT 120V 1500W HEATI...

Страница 27: ...27 655 2M Z17970 Owners Manual E Maxl Thermal Brewer NOTES...

Страница 28: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www bloomfieldworldwide com...

Отзывы: