OP
ER
AT
ION
S
20
Is the Power Supply to the
HPU on?
Have a licensed
electrician bypass the
low oil level shut off and test.
Replace if necessary. Does
the problem persist?
Check the HPU oil
level. Is the unit showing
atleast 3/4 full in the sight
glass?
HPU is equipped
with a low oil shut off
switch.
SEE WARNING.
Continue Operation.
Check that the cords are
connected and turn on the
breaker.
Fill the HPU to minimum
3/4 up the sight glass.
Have a licensed electrician
troubleshoot the main contactor or
contact
Blohm + Voss Oil Tools LLC.
Yes
No
No
Yes
Yes
START
WARNING:
MANuALLY OvERRIDING ThE LOW OIL LEvEL ShuT OFF
SWITCh BY hOLDING IN ThE CONTACTOR WILL BuRN-OuT
ThE CONTACTOR, ThuS vOIDING ANY WARRANTY ON
ELECTRICAL COMPONENTS.
HPU will not power up.
No