Attaching the Hydraulic Lines
Remove cap or plug and ensure that mating parts of the hydraulic connection are clean and
free from dirt or other contaminants. Carefully thread the connection together and tighten
appropriately.
Filling the Reservoir
The reservoir is filled via the breather connection on the top of the reservoir. Conventional
petroleum based hydraulic fluid is usually specified but care should be taken to ensure that
it is compatible with the environment it will be operated in, particularly for the ambient tem-
perature range.
Note: The compensator should be open, (unloaded) for all
cold starts, only closing once oil has warmed up.
Note: The Hydraulic Power Unit is factory set for the correct
operating pressure for proper operation of the FloorHand and
should not need to be adjusted. For troubleshooting or to
correct unauthorized tampering, a factory instruction sheet
is included at the end of this section for the Parker P2 series
pump. Any adjustments other than P-Max will void warranty.
Figure 4
Содержание 9PU-7200
Страница 5: ...5 DESCRIPTION DESCRIPTION ...
Страница 9: ...9 COMMISSIONING COMMISSIONING ...
Страница 14: ...14 INSTALLATION INSTALLATION ...
Страница 17: ...OPERATIONS 17 OPERATIONS ...
Страница 22: ...MAINTENANCE INSPECTION 22 MAINTENANCE INSPECTION ...
Страница 24: ...24 SPARE PARTS SPARE PARTS ...
Страница 26: ...26 DRAWINGS DRAWINGS ...
Страница 27: ...27 DRAWINGS Figure 9 ...
Страница 28: ...28 DRAWINGS Figure 10 ...
Страница 29: ...29 DRAWINGS Figure 11 ...
Страница 30: ...30 DRAWINGS Figure 12 ...
Страница 31: ...31 DRAWINGS Figure 13 ...
Страница 32: ...32 DRAWINGS Figure 14 Figure 15 ...
Страница 33: ...33 DRAWINGS Figure 16 ...