IQ VVC-208 Control

SETBACK

1.  Used to manually reduce the set temperature tem-

porarily during times of infrequent cooking. Press the 

SETBACK key once to reduce the set temperature to 

the pre-programmed setback temperature.

2.  Press the SETBACK key again to exit Setback and 

warm back up to the operating temperature. 

PROGRAMMING

Programming Mode for the Vision Controller is entered 

by pressing the “P” key for three (3) seconds. The follow-

ing programming mode is available on the VVC-208 as 

follows:

ACCESS LEVEL

PASSCODE

Employees

1724

Managers

6647

PROGRAM AREA

EMPLOYEE MANAGER

System

n/a

x

Recipe

x

na/

Product Name Library

x

x

Alarm Library

x

x

SCK Address

x

x

NOTE: Pressing the “P” key saves the previous param-

eter.

NOTE:  If no key is pressed within 2 minutes while in Pro-

gramming mode, the controller will automatically 

return to idle mode.

NOTE:  All scrolling will loop back through allowed values.

CHANGING THE MENU STRIP

1

Turn off the oven power.

2

With a Phillips screwdriver, remove the two screws 

that secure the bezel of the VVC-208 in place. Re-

move the bezel.

3

Remove the existing menu strip(s) by lifting the tab 

and pulling the menu strip out from the bottom of 

the controller.

4

Using the tab as a guide, slide the new menu strip 

in.

5

Replace the bezel and screws that secure it to the 

controller.

6

Turn on the oven power.

Содержание KFC CTBR-AP

Страница 1: ...ECTRIC CONVECTION OVEN INSTALLATION OPERATION MAINTENANCE BLODGETT OVEN COMPANY www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 802 658 6600 Fax 802 864 0183 PN 34532 Rev H...

Страница 2: ...Your Service Agency s Address Model Serial number Oven installed by Installation checked by...

Страница 3: ...Improper installa tion adjustment alternation service or maintenance can cause property damage in jury or death Read the instl lation operation and mainte nance instructions thoroughly before installi...

Страница 4: ...rmally lost is recirculated within the cooking chamber before being vented from the oven resulting in substantial reductions in energy consumption and en hanced oven performance electrical ratings vol...

Страница 5: ...Smoke and Grease Laden Vapors from Commercial Cooking Equipment NFPA 96 Latest Edition General export installations Installation must conform with Local and National instal lation standards Local inst...

Страница 6: ...the shelf holes with the bolt holes found near the bottom of each leg 6 Insert a carriage bolt from the outside of the leg through the leg and through the shelf corner bracket 7 Place a lock washer an...

Страница 7: ...f the oven with the bolt holes in the stand 6 Insert a bolt and washer from the top down through each of the two holes 7 Place a nut and washer on each of the bolts and tight en securely 8 Replace the...

Страница 8: ...gurations available for the CTBR AP Two CTBR AP ovens CTB biscuit oven stacked on top of a CTBR AP CTBR AP stacked on top of a Mark V See the following pages for stacking instructions for all configur...

Страница 9: ...in the top of the lower sec tion near the left hand corners 6 Lay the upper section on its back Attach the self ad hesive gasket tape to the front and side edges on the bottom of the unit 7 Set the u...

Страница 10: ...ttom of the unit 8 Set the CTBR AP upright on top of the Mark V 9 Remove the control compartment cover and access panel from the CTBR AP 10 Align the front and rear bolt holes of the CTBR AP with the...

Страница 11: ...llation Oven Assembly Figure 6 Crown Trim Stacking Plate Stud Stud View A Top Cap Stacking Plate Gasket Tape See View A Attaching the Stacking Plate to the Mark V Attaching the CTBR AP to the Stacking...

Страница 12: ...ld with the vent guard Align the mounting holes in the vent shield with top holes in the vent guard 2 Insert the flue extension over the flue on the Mark V Attach using screws provided NOTE If the ove...

Страница 13: ...this manual are fa miliar with the functions of the oven and or have had previous experience with the operation of the equipment described Ad herence to the procedures recommended herein will assure t...

Страница 14: ...oduct Buttons Used to activate cook cycles and for certain pro gramming functions 6 SCAN Key Used for recipe review during idle Used to review time remaining during multiple cooks press hold 7 COOL DO...

Страница 15: ...t is programmed for each product key 1 Press the SCAN key 2 Select any product key previously programmed LED will be lit above the key 3 Press the DOWN arrow key to scroll through the list 4 Press SCA...

Страница 16: ...a Employee Manager System n a X Recipe X na Product Name Library X X Alarm Library X X SCK Address X X NOTE Pressing the P key saves the previous param eter NOTE If no key is pressed within 2 minutes...

Страница 17: ...he P key 3 Choose a Product Key Recipe SELECT PRODUCT TO PROGRAM Choices are ALL NAME TIME TEMPERATURE TIMING SENSI TIVITY FAN SPEED FAN CYCLE FAN PULSE ON FAN PULSE OFF ALARM TIME ALARM NAME ALARM DO...

Страница 18: ...va lent of Degrees C Press the P key to advance to the next stage or parameter 7 Set Stage 1 Timing STAGE 1 TIMING STRAIGHT FLEX or SENSITIVITY Press the LEFT or RIGHT arrow keys to select the type of...

Страница 19: ...14 if the Alarm Time for this stage is zero Press the P key to advance to the next stage or parameter 12 Set Alarm 1 Name Selectable ALARM 1 NAM ACTION Press the UP or DOWN arrow keys to scroll throu...

Страница 20: ...AUTOMATIC MANUAL Press the LEFT or RIGHT ar row keys to select how the hold alarm is to be cancelled Press the P key to advance to the next step or parameter 19 Set Hold Fan Speed HOLD FAN SPEED HIGH...

Страница 21: ...ct Appliance Type APPLIANCE TYPE ELECTRIC HALF ELECTRIC FULL HALF AP FULL MARK V Press the LEFT or RIGHT arrow keys to select from a pre pro grammed list of appliances NOTE Changing appliance type cle...

Страница 22: ...ct keys to select the Setback temperature in the range of 140 300 F Press the P key to lock in your entry 9 Set Hold Time HOLD TIME HH MM Type in the length of hold time required The value is in the r...

Страница 23: ...keys to scroll to Exit 15 Press the P key to return to idle mode Product or Alarm Name Libraries 6647 key press display action 1 Enter Program mode To enter programming mode press and hold the P key f...

Страница 24: ...library traditional method 4B Once name is located press the SCAN key to toggle from predictive text input to traditional text input 4C Use the LEFT and RIGHT arrow keys to move the cursor Press HOLD...

Страница 25: ...r entry Scroll to SCK Address Press P to advance 3 Set SCK Address SCK ADDRESS XX Press the LEFT or RIGHT ar row keys to scroll through the SCK address to be used for this controller The range is from...

Страница 26: ...se the L shaped brush to clean behind the probe 2 Use a damp towel to wipe the probe Cleaning Behind the Baffle Panel 1 Use the hand brush to clean around the heating ele ment area behind the baffle p...

Отзывы: