![Blodgett Combi Manual Control BCM Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/blodgett-combi/manual-control-bcm/manual-control-bcm_service-and-installation-manual_2773810026.webp)
BCP & BCM
,
ERROR CODES & CAUSES
28
–
Main Alarm Error
–No 24V signal to high limit board
29
–
Door Sensor Error
– Wrong door sensor signal
34
–
Water Pressure Low
– Water Pressure Switch (located on the larger solenoid assembly) is closed.
(Opens at 22 PSI)
36
–
No Detergent
– Time Based detergent monitoring is disabled.
38
–
Detergent In Oven
– Combi wash interrupted while the detergent was in the oven. Run Combi
Wash in Step 0 to clear detergent prior to inserting product.
39
–
Insufficient Memory
– The units memory is not sufficient for the current operation.
40
-
IO Board Hot-
The IO Board senses a temperature above 140°F.
41
– Main Alarm -
42
–
Error in SW
– Software Error. Reboot software to current version.
For Gas Ovens
44
-
Dammper Error
-Failure during initialization of exhaust at oven start-up.
45
-
24V Error
-24V missing or failure of main contactor output.
50
-
Switch On
-Pressure switch on when gas-air control unit running (timeout 20 sec.)
51
-
Switch Off
-Pressure switch not on when gas-air control unit running (timeout 20 sec.)
52
-
Gas Valve
-Gas valve does not open (automatic gas burner control has failed (timeout 20 sec.))
53
-
No Fan RPM
-Gas-air control unit does not revolve when pressure switch is on.
54
-
Fan Error
-Gas-air control unit does not run at correct RPM just before ignition.
55
-
Gas Fail
-Warning: Ignition failed.
56
-
Gas Error
-Flame fails to occur after 3 attempts.
57
-
Gas Stop
-Warning: Gas failure during operation.