- 18 - 

User Menu B1-B7 

 

B1 Save pre-settings 

In this function, you save the preset time and temperature. 

 

If, for instance, the end user uses HOT AIR at 180°C for 30 minutes, the standard setting can be 
changed as follows: 
 

1.

 

Change time and temperature. 

2.

 

Enter user menu (keep pressing alarm key for 5 sec.)  

3.

 

Select B1 (save pre-settings). 

4.

 

Press alarm key to accept. 

 

You can only save the settings when the control lamp next to the alarm key flashes. 
 

B2 Timer start 

(Please see user manual) 
 

B3 Sound level low 

In this function, you adjust the sound that is heard when a key is activated. The sound level can be 
adjusted from 0 to 9 (0 is no sound at all). 
You adjust the sound level by pressing the step key. 

 
B4 Sound level high 

In this function, you adjust the sound that comes from the alarm. The sound level can be adjusted 
from 1 to 9 (1 is very low). 
You adjust the sound by pressing the step key. 
 

B5 Sound frequency 

In this function, you adjust the sound frequency. 
The sound frequency can be adjusted from 1 to 9. 
You adjust the sound by pressing the step key. 
You test the sound by pressing the alarm key. 

 
B6 Interior light 

In this function, you adjust the interior light. 
The light can be set at 0 or 5. 
 

0= Light is always on. 

 

5= Light goes out when the oven has been idle for 5 minutes. 

You adjust the interior light by pressing the step key. 

 
B7 Current temperature 

In this function, you choose whether the oven should display the current temperature or the preset 
temperature. 
You choose between 0 and 1 
 

0= The preset temperature is shown. 

 

1= The current temperature is shown. 

You change the setting with the step key. 

Содержание Manual Control BCM

Страница 1: ...GB Service Installation Manual For BCM Electric Oven Manual Control...

Страница 2: ...est Mode D21 D28 15 User Menu 17 User Menu B1 B7 18 User Menu B8 B13 19 User Menu B14 B21 20 User Menu B22 B24 21 Error Codes 22 Error Code List 23 Error Codes Guide Notes 24 Sequence of operation Off...

Страница 3: ...the BLODGETT ovens are equipped with a drain system that removes surplus water from the oven chamber This water may be condensed water from the products or it may occur when the oven chamber is cooled...

Страница 4: ...rmity with the above requirements the installation of a water filter in front of the water connection to the oven is recommended 1 1 connection for raw water for the condensation jet cold water Locate...

Страница 5: ...or 5 Installation and Connection Electrical connection survey of supply lines The electrical connection must be carried out by an authorised electrician in accordance with existing rules and regulatio...

Страница 6: ...for correct electrical connection Check connection to drip tray Check for correct mounting of drip tray Check for correct fall of hose from drip tray and check for leaks Check for correct exhaust and...

Страница 7: ...injection time with turn switch B model only PRG Change oven temperature with turn switch Change time with turn switch Core temperature on C and K models Injection time on B model Program key Step ke...

Страница 8: ...the computer control of the oven model in question The program display shows a description of the U function in question Display shows setting Not active Display shows U No Display shows description...

Страница 9: ...urrent temperature by pressing the temperature key 0 OFF 1 ON When you have chosen the temperature scale confirm by pressing the alarm key if the control lamp flashes After that the controller initial...

Страница 10: ...F 1 ON U12 Drain cooling You activate and deactivate drain cooling by pressing the step key 0 OFF 1 ON U13 Timer start You activate or deactivate timer start by pressing the step key 0 OFF 1 ON U14 De...

Страница 11: ...Not active Not active Possible to choose a d function with turn switch Not active Test Mode To enter test mode press hot air key and combi steam key for 2 sec To exit test mode turn switch left Change...

Страница 12: ...te the function by pressing the step key However this function can only be activated when there is water in the steam generator To pulse press the alarm key 0 OFF 1 ON D3 Fan right hand high low This...

Страница 13: ...nals 4 and 5 In the display next to Time it is possible to read which outlet is active OFOF both outlets are off ONOF outlet 4 is active and outlet 5 is off OFON outlet 4 is off and outlet 5 is active...

Страница 14: ...wn To adjust the temperature press the time key until the digit in the display flashes Then adjust upwards or downwards until the correct temperature is shown Finally press the time key again to save...

Страница 15: ...onnected which is why there is only one input signal D23 Thermo switch fan Here it is possible to read the status of S2 and S2A In the display next to Time it is shown whether the circuit is connected...

Страница 16: ...eset thermo switch Q3 which is located at the bottom of the oven below the operation panel D37 Motor RPM 1 Here it is possible to read the number of revolutions for fan motor 1 The number of revolutio...

Страница 17: ...etting Not active Not active Not active Not active Not active Press key for 5 sec to access user menu Turn switch Main switch Start Stop User Menu To enter user menu press alarm key for 5 sec To exit...

Страница 18: ...und level high In this function you adjust the sound that comes from the alarm The sound level can be adjusted from 1 to 9 1 is very low You adjust the sound by pressing the step key B5 Sound frequenc...

Страница 19: ...emperature display digit flashes 2 Turn the switch to the desired setting of hours 3 Press the key next to the temperature display digit stops flashing You can set the hours from 0 to 23 The oven s cl...

Страница 20: ...xt to the temperature display digit flashes 2 Turn the switch to the desired time 3 Press the key next to the temperature display digit stops flashing You set the time from 2 to 50 sec B18 Pulsing int...

Страница 21: ...eriod of time B23 Language In this function you change the language of the computer Press step key and select 1 2 3 or 4 There are also four language variants A D see below To change the language you...

Страница 22: ...PRG Error codes All keys can be used to acknowledge an error message Display shows error Er No Display shows description of error Turn switch Main switch Start Stop...

Страница 23: ...rror code 13 GENER 130 Generator too hot Temperature in steam generator higher than 130 C If fault recurs descale generator Error code 14 FAN SPEED Fan running too slow Error code 15 CPU HOT CPU board...

Страница 24: ..._____________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________...

Страница 25: ...fill in 5 minutes 12 SSR Hot one of the two SSR Heat Sink Automatic Reset Snap Disks that are wired in series is Open Open at 248 F 13 Generator 265 RTD Probe in Generator 100 Ohm Probe reads over 26...

Страница 26: ...0 F 41 Main Alarm 42 Error in SW Software Error Reboot software to current version For Gas Ovens 44 Dammper Error Failure during initialization of exhaust at oven start up 45 24V Error 24V missing or...

Страница 27: ...sensor SE1 open the DC voltage is 2 5 on J1 pin 34 The IO board verifies the following with AC voltage The high limit stat of the motor is closed sending 24 VAC to J1 pin 10 The high limit stat of th...

Страница 28: ...model 1 and 2 if no boiler DC coming from J2 pin 22 and 23 The IO board will get a resistance input from P1 oven temperature sensor PT100 on J1 pin 37 and 38 telling the IO board when to switch off t...

Страница 29: ...d will cut off the MV2 valve When the HIGH level is registered the SSR gets DC voltage on the terminal 2 DC coming from J2 pin 22 and 25 to heat up the water If the level sensor register LOW level not...

Страница 30: ...n 100 speed If the temperature is above 150 C 302 F the MV1 injection valve will be activated 24 VAC IO board J2 pin 8 for 0 1 sec and then off for 1 sec the sequence will continue until the temperatu...

Страница 31: ...B C K controller Keyboard Testpins CPU Power 5V 3 3V 24V AC Programming connector Start IO reset Short Encoder Power 24V AC Start IO COM IO 5V Clock Must flash 1 sec Short flash at start up RS232 Not...

Страница 32: ...j 2011 Dias 6 Back side B C K controler Keyboard Buzzer Memory key connector Programming connector Buzzer Battery 3V RS232 not used Encoder Power 1 6 Power Power 1 2 1 2 COM IO COM IO 3 3 GND GND 4 4...

Страница 33: ...e 76 P3 8 100k Ohm Boiler Probe 69 P1 9 100k Ohm Cavity Probe 68 P1 10 100k Ohm Cavity Probe 88 SE3A 11 Not used 87 SE3 12 Speed sensor Motor sig 211 SE1 13 Speed sensor Motor 5V 90 X90 13 Not used 21...

Страница 34: ...c Mode d Level stic mode allows you to navigate through all components to test them without the oven Press and hold the Hot Air and Combi keys simultaneously t displayed next to the PROG key and then...

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ......

Страница 41: ......

Страница 42: ......

Страница 43: ...Dias 2 HOUN A S 9 maj 2011 Dias 2 Wiring diagram Page 1 High limit Input Output Supply Com to CPU Oven light Cooling fan empty pump CombiWash pump vent Input to IO board To high limit components High...

Страница 44: ...no 1 Solid state relay no 2 Main fuse for transformer fase Ring element 400 motor 1 Ring element 470 motor 1 Ring element 400 motor 2 Ring element 470 motor 2 Main fuse for transformer neutral Main te...

Страница 45: ...no 3 Solid state relay no 4 Connection to main contactor Please note this is only for K KPE Element steam boiler High limit steam boiler 135 C Top element steam boiler Temp sensor steam boiler Elemen...

Страница 46: ...tor Frequency inverter Connection to main fuse F5 Fuse for interior light Fuse for IO and CPU board Fuse for all 24V output Connection to neutral terminal Buzzer Sound Interior light Plug on IO board...

Страница 47: ...larm sens print Sensor for ClimaOptima Doorsensor singel door Temp sensor drain Core probe temp sensor 2 Core probe temp sensor 1 Oven temp sensor Sensor for water pressure Restart switch Doorsensor i...

Страница 48: ...t SSR High limit SSR if more than 2 SSR Solenoid valve filling boiler Solenoid valve CombiWash Lamp in restart button Connections to frequency inverter Connections to solid stat relay High limit motor...

Страница 49: ...n to Fuse F3 Connection to terminal 2 ext vent Connection to Fuse F5 Connection to Fuse F5 Rinse pump Detergent pump Connection to Fuse F3 Connection to terminal 1 Connection to neutral terminal Empty...

Отзывы: