6-11
Flow rate
No used in the current program version. Always 0.
Input signal (mV/V)
This register holds the current input signal in mV/V. This register could be used for fault
finding in the system.
Analog output value
This register hold the value sent to the analog output. The registers can be used for
fault finding in the system. The value is rounded to 3 decimals.
Status of digital inputs 1 - 4
Bits set to 1 in this register have the following meaning:
Bit no Function
0
Digital input 1 activated.
1
Digital input 2 activated.
2
Digital input 3 activated.
3
Digital input 4 activated.
Note: If this register (bits) is read as float value,
see description of Data representation.
Status of digital outputs 1 - 4
Bits set to 1 in this register have the following meaning:
Bit no Function
0
Digital output 1 activated.
1
Digital output 2 activated.
2
Digital output 3 activated.
3
Digital output 4 activated.
Note: If this register (bits) is read as float value,
see description of Data representation.