Technical Manual
9-12
Information for Discontinuous Totalizing automatic Weighing out by Tare
Accumulation and Long-term Data Store.
Long-term Store to be read by FTP client, not legal read if system not legal.
Do a ‘Clock Set-up’ from the master to G5 PM in a daily manner.
If accumulation shall be done at print command for weighing values under or
over load (+/-9e) then the ‘Allow Under-/Overload’ shall be set to ‘Allowed (with
warning)’ in the G5 PM, the legal requirements check are then not done in the
G5 PM.
If accumulation shall be done at print command for weighing values under ‘Min.
Weight Print‘ then the ‘Allow Print Low Weight’ shall be set to ‘Allowed (with
warning)’ in the G5 PM, the legal requirements check are then not done in the
G5 PM.
It is three decimals in Accumulated weight, at display, at printout and in Long-
term Store.
In Printer set up set ‘Gross After Print’ to ‘Yes’ for automatic change from Net
weight to Gross weight on display at a print command.
For weighing and mV/V values it is an extra figure in calibration menu, G5 PM
can always be configure with extra weighing resolution (not in legal application).
For very frequent weighing use Long-term Store with FTP not Printer.
For Digital Output configure ‘Output Source’ to ‘Print Weight Warning’ for
suitable digital output.
Automatic Catchweighing Instrument
OIML 51-1:2006
Weighing instrument
For G5 PM to be a legal part in an Automatic catchweighing instrument the
following system requirements has to be fulfilled.
1. Settings shall be in accordance with above settings (chapter 2) except for
some application dependent settings.
2. A master shall take care of all system aspects regarding controlling parts
integrated in the instrument (as starting and stopping motors, warnings,
controlling G5 PM etc.).
3. The master shall communicate with G5 PM over Ethernet Modbus TCP/IP
or Serial communication, RS485 Modbus RTU, if a printer is required it will
occupy the RS485 port (see G5 Weighing Instrument Technical Manual).
4. G5 PM will by the Modbus protocol respond with weight, status and other
data depending on register that is read, it is up to master to check status
from G5 PM when fetching weight or accumulated data.
5. The master can also send commands to the G5 PM, for example the Print
command.
6. G5 PM shall have accuracy class Y(a) (500 to 10000 scale intervals).
7. Minimum capacity shall not be less than 20e.
8. The units of mass to be used are gram (g), kilogram (kg) and tonne (t).