Lit. No. 68251, Rev. 09
21
May 1, 2021
ELECTRICAL INSTALLATION — SNOWPLOW SIDE
1. Connect the red power wire from the snowplow
harness to the pump motor terminal stud.
Hardware provided on pump.
2. Place the 3/8" lock washer, the black ground
wire (from the harness), and the red ground wire
on the coil harness (from the manifold) over
the tapped hole on the pump and secure with
3/8" x 3/4" screw.
3. Remove the nut and washer from the
POWER HITCH™ connect/disconnect toggle
switch and insert it through the back of the
mounting bracket on the A-frame. Align the
notches on the switch and bracket. Replace
the washer and nut and tighten until the switch
is
fi
rmly in place. Attach the connector on the
snowplow harness to the switch.
NOTE: Use caution when connecting. Switches
can break if this is done forcefully.
4. Attach the connector on the harness to the
connector on the coil harness.
5. Position the harness braid in the notch on the
switch bracket and secure it with a cable tie.
NOTE: The diode loop harness should be inside of
the pump cover.
6. Install the pump and manifold cover by aligning
the notches in the cover with the welded bolts
on the A-frame brackets. Secure with clamping
knob. Verify that the cover is positioned over the
protective toggle switch hood. Pop the front of the
cover on the threaded stud and secure it with the
remaining knob.
The pump cover installs over
the top of the draw latch
switch bracket.
Содержание POWER PLOW 810-1
Страница 50: ...Lit No 68251 Rev 09 50 May 1 2021 NOTES...
Страница 51: ...Lit No 68251 Rev 09 51 May 1 2021 NOTES...