Operating Instructions for Suspended Jacks
16
7
Maintenance and Repair
WARNING
Risk of injury and material damage
Perform maintenance and repair of the lift always without a load.
Safety notes
Maintenance and repair work on the jack may be performed only by specialists.
Disconnect the jack from the compressed air supply or from the electrical mains before carrying
out any maintenance and repair work.
After maintenance and repair work on the hydraulic system, the system must be vented.
Always retighten screwed connections loosened during maintenance and repair work.
Do not clean the jack with a high-pressure or steam jet.
As there is a high risk of slipping on an oily workshop floor, always catch oil in a suitable
container and dispose of it correctly.
When handling oil, grease, and chemical substances, the safety regulations for the product must
be observed.
Do not use aggressive cleaning agents to clean the lift.
Use only original spare parts of the manufacturer (
11) and approved supplies (
7.7).
Pay attention to safe and environment-friendly disposal of lubricants and auxiliary materials (e.g.
hydraulic oil) and replaced parts.
7.1
Maintenance Intervals
Lifts in continuous operation or in especially contaminated surroundings shall be serviced more
frequently.
Weekly
Perform function test. (
Check compressed air supply. (
Top up anti-rust oil. (
Check the hydraulic oil level. (
Check connection cables/hoses for damage and abrasion.
Lubricate castors.
Clean the jack and apply rust preventives.
Annually
Perform the safety test. (
Change the hydraulic oil. (
Clean and grease the bearings of all castors.
Check track width of the transversely adjustable undercarriage (
Check screw connections of the undercarriage and tighten, if necessary (
Every 5 years
Replace hydraulic hoses. (
7.2
Perform Function Test
Test the full functionality of the jack without load.
Test the full functionality of the jack with load.
In case of a malfunction, stop the lift immediately and secure it. Have any faults repaired
immediately, and insure problem-free operation.
7.3
Check Compressed Air Supply
Check and maintain the filter and water separator according to the manufacturer’s instructions.
Check supply pressure. (
H P
Содержание GH Series
Страница 4: ...Operating Instructions for Suspended Jacks 4 9 10 8 6 2 7 3 4 5 Series Blitz S 15 Vario H ...
Страница 43: ......