Example:
23. OBJECT 1018H: IDENTITY DATA
a. Number of mapped objects
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
18h
CAN Object 1018h
Byte 2
10h
Byte 3
00h
Sub index
Byte 4,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 18 10 00 00 00 00 00
Keypad Reply
595
Std
4F 18 10 00 04 00 00 00
4
Number of mapped objects: 4
Example:
Example:
b. Vendor ID
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
18h
CAN Object 1018h
Byte 2
10h
Byte 3
01h
Sub index
Byte 4,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 18 10 01 00 00 00 00
Keypad Reply
595
Std
43 18 10 01 5A 03 00 00
000035Ah
Vendor Id: 000035Ah
c. Product code
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
18h
CAN Object 1018h
Byte 2
10h
Byte 3
02h
Sub index
Byte 4,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 18 10 02 00 00 00 00
Keypad Reply
595
Std
43 18 10 02 00 00 00 00
00h
Product code: 0h
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - [email protected]
28
FOR REFERENCE ON
LY