Example:
Example:
•
PKP 2600
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
02h
CAN Object 6002h
Byte 2
60h
Byte 3
00h
Sub index
Byte 4
XYh
X: R8 R7 R6 R5
Red LED
Y: R4 R3 R2 R1
Red LED
Byte 5
ZKh
Z: G4 G3 G2 G1
Green LED
K: R12 R11 R10 R9
Red LED
Byte 6
ABh
A: G12 G11 G10 G9
Green LED
B: G8 G7 G6 G5
Green LED
Byte 7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
23 02 60 00 00 00 00 00
No LED blinks
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
To Keypad
615
Std
23 02 60 00 10 20 40 00
Only red LED #5,
green LED #2 and
#11 blink.
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
To Keypad
615
Std
23 02 60 00 00 00 05 00
Only green LED #5
and #7 blink.
Keypad Reply
595
Std
60 02 60 00 00 00 00 00
b) Read LED blink
•
PKP 2200
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
02h
CAN Object 6002h
Byte 2
60h
Byte 3
00h
Sub index
Byte 4,7
00h
Not Used
Direction
Identifier
Format
Message
Data
Example:
Example:
Example:
To Keypad
615
Std
40 02 60 00 00 00 00 00
Keypad Reply
595
Std
43 02 60 00 FF 00 00 00
All LED blink
To Keypad
615
Std
40 02 60 00 00 00 00 00
Keypad Reply
595
Std
43 02 60 00 81 00 00 00
Red LED #1and
green LED #4 blink
To Keypad
615
Std
40 02 60 00 00 00 00 00
Keypad Reply
595
Std
43 02 60 00 08 00 00 00
Red LED #4 blink
Blink S.r.l.
Via
Montefeltro, 6
- 20156 Milano - Italy - Tel. +39 02 3088583 - Fax +39 02 33406697
www.blinkmarine.com - [email protected]
22
FOR REFERENCE ON
LY