This module sets and reads the LED Blink States.
Each bit position represents the corresponding LED. A one indicates the LED is blinking a zero indicates
the LED is not blinking. If the blink message is sent when the LED is already ON, the LED blinks in
alternative mode.
10
14. OBJECT 2002H: DIGITAL OUTPUT MODULE
a) Set LED Blink
• PK2300
B) Read LED Blink
• PK2300
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
02h
CAN Object 2002h
Byte 2
20h
Byte 3
XXh
XX: Sub index
01h: Red Led
02h: Green Led
03h: Blue Led
Byte 4
YYh
0 0 L6 L5 L4 L3 L2 L1 LED position
Byte 5,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 02 20 01 04 00 00 00
Set red LED #3 blink
Keypad Reply
595
Std
60 02 20 00 00 00 00 00
To Keypad
615
Std
2F 02 20 03 20 00 00 00
Set blue LED #6 blink
Keypad Reply
595
Std
60 02 20 00 00 00 00 00
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
02h
CAN Object 2002h
Byte 2
20h
Byte 3
XXh
XX: Sub index
01h: Red Led
02h: Green Led
03h: Blue Led
Byte 4,7
00h
Not used
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 02 20 01 00 00 00 00
Read red LED blink
Keypad Reply
595
Std
4F 02 20 01 3F 00 00 00
All red LED blink
To Keypad
615
Std
40 02 20 02 00 00 00 00
Read green LED blink
Keypad Reply
595
Std
4F 02 20 02 01 00 00 00
Green LED #1 blink
To Keypad
615
Std
40 02 20 03 00 00 00 00
Read blue LED blink
Keypad Reply
595
Std
4F 02 20 03 00 00 00 00
No blue LED blink