Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 8 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2400-LI_J1939_UM_REV1.0
10.
Set startup keys message(28h)
This command enables the transmission during power up of the state of the keys.
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
28h
Startup keys message
Byte 3
XXh
XX:
00h Disabled (default)
01h Enabled
Byte 4,7
FFh
Not used
Example:
Direction
Identifier
Format
Message
Data
To
Keypad
18EF2100h Ext
04 1B 28 01 FF FF
FF FF
Enable startup keys
message
11.
Get software revision (2Ah)
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
2Ah
Get software revision
Byte 3,7
FFh
Not used
Answer:
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
2Ah
Get software revision
Byte 3,6
XXh XXh XXh XXh
SW revision ASCII
Byte 7
00h
Not used
Example
Direction
Identifier
Format Message
Data
To Keypad
18EF2100h Ext
04 1B 2A FF FF FF FF
FF
Get software
revision
From
Keypad
18EFFF21h
Ext
04 1B 2A 56 32 2E
36 00
V2.6
12.
Set startup LED show (34h)
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
34h
Startup LED show
Byte 3
XXh
XX:
00h OFF
01h Complete led show (default)
02h Fast flash
Byte 4,7
FFh
Not used
Example
Direction
Identifier
Format Message
Data
To
Keypad
18EF2100h Ext
04 1B 34 00 FF FF
FF FF
Set Startup LED show
OFF