background image

BrewEasy™ Compact Tri-Clamp V1 

© Blichmann Engineering, LLC 2021 

For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts

7

Tips for success:

•  Do not skip the pH measurements! If your mash is much above the recommended pH you risk astringency in your 

beer among other detrimental changes. Adding water salts and acid may be necessary to achieve proper pH in 

any all-grain brewing system.

•  During dough-in, an occasional gentle stirring will break up any clumps and release air pockets. The dough-in 

process is vital for problem free recirculation.

•  Let the grain sit (dough-in) for about 10 min to absorb the liquor and for the air to purge out of the grain. 

•  Consult the two recommended books, How to Brew and Water by John Palmer and Colin Kaminski (published by 

the Brewers Association) to learn how to properly adjust your mash pH and to educate yourself on good brewing 

practices.

•  Measure the specific gravity periodically. The SG of the mash is the same as the pre-boil wort SG. Make adjust-

ments to your wort such as adding malt extract, water, or mashing longer to achieve the desired SG of the pre-boil 

wort

Tip:

 As with any new system it will take a few batches to dial in your efficiency and water usage requirements. Always 

make careful notes, and closely follow recommendations found in this manual.  If you are new to all grain brewing we 

suggest reading John Palmer’s book “

How to Brew”

, published by the Brewers Association before your first batch.  This 

manual is not intended to be a complete all-grain brewing text.

IMPORTANT: 

The quality of your finished beer will be directly related to the quality of your brewing water. If you have 

especially hard water in your area, it is strongly recommended that you dilute your tap water with distilled or reverse 

osmosis water or build your brewing water from scratch. For optimum results, the mash pH must fall within a range 

of 5.2 – 5.6 at room temperature. Additionally, a minimum of 100 ppm of Ca is required. For more information, further 

reading is recommended, specifically John Palmer & Colin Kaminski’s book “

Water

”, published by the Brewers 

Association.

IMPORTANT: 

 We highly recommend the purchase of a digital pH meter for monitoring pH.  Test strips, while 

inexpensive, do not provide adequate precision for brewing.  Despite many pH meters being automatic temperature 

correcting, pH levels change with temperature. If you are reading the meter at mash temperatures, the range for mash 

pH is between 5.1 and 5.4 pH. This will result in a room temperature pH at the recommended range of 5.2-5.6 pH.

Cleaning Procedures

Cleaning of the BrewEasy™ Compact system is very straight-forward. Clean any components that will contact the

liquid, wort, or other brewing ingredients with a mild detergent (non- chlorine) or Powdered Brewery Wash (PBW)

before your first use and after every subsequent use. Soak the hoses in a PBW solution, rinse with hot tap water and 

soak in a non-chlorine sanitizer.

Содержание BrewEasy Compact TC

Страница 1: ...ntact your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Important should specifically be followed to ensure satisfactory results with the product WARNING CAUTION IMPORTANT IMPORTANTINFORMATION PLEASEREADANDTHOROUGHLYUNDERSTANDTHISMANUALPRIORTOUSE FORIMPORTANTSAFETYINFORMATION Brewing has inherent hazards and requires care focus and a mindset of safety ...

Страница 2: ...ander 120V Electric 120V BrewCommander 1 Comes with 120V selection aBrewCommander Gas Gas BrewCommander 1 Optional with gas selection BMA 002F A Brewmometer F 1 Optional with gas selection Recirculation Kit Parts BE 001996 00 Sparge Tube Kit 1 BE 500004 00 Sparge Tube Port Bulkhead 1 BE 000067 00 Retaining O ring 2 KTL 010 00 Retaining Washer 2 BE 000623 01 Wort Flow Meter 1 BE 000359 00 Silicone ...

Страница 3: ...386 00 4 Rotating DipTube BE 001686 02 5 1 5 Gasket BE 000868 00 6 1 5 Clamp BE 000633 00 7 G2Tri ClampValve BE 002055 00 1 2 3 4 5 6 7 The following steps contain assembly procedures for optional accessories that may not pertain your system Step Three If you purchased your system with a controller install the temperature probe into the tri clamp adapter cap and install on the back left tri clamp ...

Страница 4: ...ht barb QuickConnectors go on the hose that attaches to the drain valve and the pump inlet TIP On straight QuickConnectors leave approximately 1 8 of space between the QuickConnector nut and silicone hose before tightening the plastic clamp TIP Install the QuickConnectors is such a way that minimizes the potential for kinks that can restrict flow TIP Do not mount the pump higher than the standard ...

Страница 5: ...nto the two smaller holes on the back right side of your kettle The threaded ends should point outward and will be used to connect the power cable to the BoilCoil Slide the rectangular metal frame onto the two protruding ends and using a 7 8 socket wrench tighten the nuts onto the threads of the BoilCoil Plug the power cable into the BoilCoil and connect the other end to the BrewCommander Step Sev...

Страница 6: ...ded 10 minutes turn the pump on and allow the BrewEasy to continuous ly recirculate the wort for the duration of the mashing period Set the flow of the pump to 0 75 gallons per minute and monitor this flow by checking the flow meter throughout the mash If desired after starch conversion you can heat the mash to the desired mash out temperature using the same method described in the Mashing section...

Страница 7: ...eading John Palmer s book How to Brew published by the Brewers Association before your first batch This manual is not intended to be a complete all grain brewing text IMPORTANT The quality of your finished beer will be directly related to the quality of your brewing water If you have especially hard water in your area it is strongly recommended that you dilute your tap water with distilled or reve...

Страница 8: ...nty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limited warranty 2 Blichm...

Отзывы: