background image

BrewEasy™ Compact Tri-Clamp V1 

© Blichmann Engineering, LLC 2021 

For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts

1

BrewEasy

 Compact TC

Assembly, Operation, & Maintenance

Congratulations on your purchase and thank you for selecting the BrewEasy™ Compact 

from Blichmann Engineering™. We are confident that it will provide you years of service 

and many gallons of outstanding beer. This manual will familiarize you with the use, 
assembly, and sanitation procedures for the product.

Sections labeled “Warning” can lead to serious injury or death if not followed. Please thoroughly read these sections 

and understand them completely before use. If you do not understand them or have any questions, contact your  

retailer or Blichmann Engineering (www.BlichmannEngineering.com) before use.

 

Sections labeled “Caution” can lead to equipment damage or unsatisfactory performance of the equipment. Please 

read these sections thoroughly. If you have any questions, contact your retailer or Blichmann Engineering  

(www.BlichmannEngineering.com) before use.

 

Sections labeled “Important” should specifically be followed to ensure satisfactory results with the product. 

WARNING:

CAUTION:

 

IMPORTANT:

IMPORTANT INFORMATION

PLEASE READ AND THOROUGHLY UNDERSTAND THIS MANUAL PRIOR TO USE  

FOR IMPORTANT SAFETY INFORMATION!

Brewing has inherent hazards and requires care, focus, and a mindset of safety and precaution.  Hot liquids, steam, flame, 

electricity, heavy lifting, slippery surfaces, cuts, and harsh chemicals to name a few.  

•  Always thoroughly read and understand all product manuals before using the product.

•  Always keep children and pets safely away from the brewing area.

•  Always wear protective clothing, safety glasses/goggles, shoes, and burn/chemical resistant gloves.

•  Always use GFCI protected circuits for ALL electrical equipment.

• 

Always keep flame away from flammable surfaces.

•  Always brew on hard surfaces such as concrete.

•  Always disconnect electrical equipment from power and propane tanks after each use.

•  Never lift hot and/or heavy liquids.

•  Never use drugs or alcohol while brewing.

•  Never leave the brewing area unattended.

Содержание BrewEasy Compact TC

Страница 1: ...ntact your retailer or Blichmann Engineering www BlichmannEngineering com before use Sections labeled Important should specifically be followed to ensure satisfactory results with the product WARNING CAUTION IMPORTANT IMPORTANTINFORMATION PLEASEREADANDTHOROUGHLYUNDERSTANDTHISMANUALPRIORTOUSE FORIMPORTANTSAFETYINFORMATION Brewing has inherent hazards and requires care focus and a mindset of safety ...

Страница 2: ...ander 120V Electric 120V BrewCommander 1 Comes with 120V selection aBrewCommander Gas Gas BrewCommander 1 Optional with gas selection BMA 002F A Brewmometer F 1 Optional with gas selection Recirculation Kit Parts BE 001996 00 Sparge Tube Kit 1 BE 500004 00 Sparge Tube Port Bulkhead 1 BE 000067 00 Retaining O ring 2 KTL 010 00 Retaining Washer 2 BE 000623 01 Wort Flow Meter 1 BE 000359 00 Silicone ...

Страница 3: ...386 00 4 Rotating DipTube BE 001686 02 5 1 5 Gasket BE 000868 00 6 1 5 Clamp BE 000633 00 7 G2Tri ClampValve BE 002055 00 1 2 3 4 5 6 7 The following steps contain assembly procedures for optional accessories that may not pertain your system Step Three If you purchased your system with a controller install the temperature probe into the tri clamp adapter cap and install on the back left tri clamp ...

Страница 4: ...ht barb QuickConnectors go on the hose that attaches to the drain valve and the pump inlet TIP On straight QuickConnectors leave approximately 1 8 of space between the QuickConnector nut and silicone hose before tightening the plastic clamp TIP Install the QuickConnectors is such a way that minimizes the potential for kinks that can restrict flow TIP Do not mount the pump higher than the standard ...

Страница 5: ...nto the two smaller holes on the back right side of your kettle The threaded ends should point outward and will be used to connect the power cable to the BoilCoil Slide the rectangular metal frame onto the two protruding ends and using a 7 8 socket wrench tighten the nuts onto the threads of the BoilCoil Plug the power cable into the BoilCoil and connect the other end to the BrewCommander Step Sev...

Страница 6: ...ded 10 minutes turn the pump on and allow the BrewEasy to continuous ly recirculate the wort for the duration of the mashing period Set the flow of the pump to 0 75 gallons per minute and monitor this flow by checking the flow meter throughout the mash If desired after starch conversion you can heat the mash to the desired mash out temperature using the same method described in the Mashing section...

Страница 7: ...eading John Palmer s book How to Brew published by the Brewers Association before your first batch This manual is not intended to be a complete all grain brewing text IMPORTANT The quality of your finished beer will be directly related to the quality of your brewing water If you have especially hard water in your area it is strongly recommended that you dilute your tap water with distilled or reve...

Страница 8: ...nty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warranty of fitness for a particular purpose or merchantability on items excluded from coverage as set forth in this limited warranty 2 Blichm...

Отзывы: