Be certain your appliance is properly installed and grounded by a qualified technician in accordance with
applicable codes. To guarantee the electrical safety of this appliance, continuity must exist between the
appliance and an effective grounding system. It is imperative that this basic safety requirement be met.
The manufacturer cannot be held responsible for damages caused by the lack or inadequacy of an effective
grounding system.
This appliance conforms to all uniform electrical safety codes and electrical grounding regulations. Install
unit according to I.A.W. local codes or with National Electrical Code ANSI/NFPA 70 or CSA C22.1 in their
absence.
Gas Safety and Installation Warnings
•
All gas connections should be made by a Professional qualified technician and in accordance with local
codes and ordinances. The installation must conform with local codes or, in the absence of
local codes, with either the national Fuel Gas Code, ANSI Z223.1/NFPA 54, or CAN/CGA-B149.1,
Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code.
•
Always check the Rating Plate to make sure the gas supply you are hooking up to is the gas type
the appliance is manufactured for.
•
Check the rating label on the left hand outside of the double side burner. Rating label for single
burner is located inside of the burner hood.
•
Do not twist the gas supply hose.
•
Before each use, visually inspect the gas supply hose for cracks, cuts or excessive wear. Replace
the hose if necessary. Check for gas leaks.
•
Gas Specifications: Be sure that the gas supplied to the appliance conforms to the model you
purchased. A Natural Gas appliance requires natural gas to operate; an LP appliance requires liquid
propane gas to operate.
•
Never connect the appliance to an unregulated gas supply line. Appliances operated without a regulator
are unsafe and will not be serviced until installed properly and safely. Unsafe operation without a gas
regulator will void the warranty of the appliance.
RATING PLATE LOCATION