The appliance must be completely cooled before proceeding. Make sure the gas supply is off and all control
knobs are in the “OFF” position. You must remove all cooking grate to expose the main burners in the appliance.
Keep all burner ports free of obstructions with a small metal object. Clean out any debris inside the burner head
and inspect the burner inlet to ensure it is free of any obstructions. Use a rod or pipe cleaner to remove any debris
within the burner if necessary.
SPIDER
AND
INSECT
WARNING
Spiders and other insects can nest in the burner of this and any other Power Burner, which causes the gas
to flow from the front of the burner. This dangerous “condition” can cause a fire behind the valve panel,
damaging the Power Burner and making the Power Burner unsafe to operate. Inspect the burners before
each use. Symptoms of insect nests can include any of the following conditions:
1) The smell of gas in conjunction with the burner flames appearing yellow.
2) The Power Burner does not reach temperature.
3) The Power Burner heats unevenly.
4) The burner makes popping noises.
Fuel Conversion
CAUTION:
This should only by performed by a licensed gas professional.
Gas Regulator :
Currently all Natural Gas burners are supplied with a regulator which is appropriate for use with Natural
Gas or low pressure Propane.
1. When converting to Propane Gas, the most common Propane canister used is a smaller sized
portable canister (typically 5 gallons or 20 pounds).The pre-installed regulator will need to be
converted to LP gas (see below) and add a secondary low pressure hose and regulator with an
outbound pressure set to approximately 11
”
of water column pressure. If an individual is intending
on using Propane provided from a larger tank permanently installed on location, the regulator
included with the appliance will only need to be converted for use with LP fuel (see NG-LP
Regulator Conversion below). Please be aware that this included regulator can only withstand
an inbound pressure of .5 PSI or roughly 14 inches of water column pressure. Any higher
pressure on location will have to be further regulated before connecting to the regulator on the
appliance. Please consult your local Propane gas provider to confirm the gas pressure on the supply
line feeding the appliance.