background image

 

 

Factors affecting the flue draught include: 

 

Insufficient flue height 

 

Trees or other buildings nearby causing turbulence 

 

High and gusty winds 

 

Outside temperature and weather conditions 

 

Blocked flue 

For advice on the correction of persistent flue problems 
consult your supplier/installer for more detail. 

 

 

 

Depending on the type of wood burnt and frequency, the 
ashes will need removing every 2 to 6 weeks. 

Excess ashes should be removed when necessary, placed in a 
non-combustible container with a tightly fitting lid and moved 
outdoors immediately to a location clear of combustible 
materials. 

 

 

 

If a flue/chimney fire occurs: 

 

Shut air slide control fully to smother the fire 

 

Do not use the appliance after a flue fire until an 
accredited installer has assessed the cause and any 
resultant damage. 

 

 

 

 

The appliance, when cool, can be cleaned with a cloth. 

 

Over the years, the black paint will fade and can be 
touched up with Stove Bright metallic black paint. 

 

To clean the glass, we recommend using a household 
window cleaner or general purpose cleaner with a soft 
cloth. 

 

Do not use abrasive cleaner or scourer pads. 

 

 

 

 

 

 

 

 

Check inside of flue prior to each season for any build-
up of creosote (wood tar). To do this: 

o

 

First remove the baffle (refer to “2. Replacement 
of Baffle” under Maintenance & Servicing 
section). 

o

 

Using a small mirror and torch hold the mirror on 
an angle below the flue with the torch shining at it 
and look for black creosote build-up. If only a fine 
black powdery layer then that is normal, but if 
built up layers of creosote can be seen, then the 
flue needs cleaning. 

o

 

Refit the baffle if no cleaning is required. 

 

To clean the flue: 

o

 

A flue cleaning brush can be purchased from most 
wood heater retail outlets or large hardware 
stores. 

o

 

The objective is to pull the brush down through 
the flue. 

o

 

With the baffle removed, tie a rope to one end 
of the brush, and drop the rope from the top 
(outside on top of the roof) down the flue. 

o

 

Grab the end of the rope inside the firebox and 
pull the brush through. 

o

 

Check the inside of the flue with the mirror 
and torch. Repeat if necessary. 

o

 

Once clean, remove any excess creosote from 
the firebox and replace the baffle. 

 

Alternatively, get a flue cleaning service to do the job 
for you (it’s a dirty job). 

 

Check flue integrity by checking that the 900mm 
flue sections have not separated at the joins. 

 

 

 

 

 

 

 

 

 

 

7. ASH REMOVAL 

 

8. FLUE/CHIMNEY FIRE 

 

9. CLEANING PAINT WORK & GLASS 

 

10. CLEANING THE FLUE 

 

Содержание B600

Страница 1: ...nd Stylish Keep instructions in a safe place for future reference DO NOT DISCARD THESE INSTRUCTIONS Pecan Engineering Pty Limited proudly supports the activities of Landcare Australia through its membership of the AHHA B600 B900 B605 B905 ...

Страница 2: ...ZS4013 WARNING DO NOT USE FLAMMABLE LIQUIDSOR AEROSOLS TO START OR REKINDLE THEFIRE WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHENIT IS OPERATING WARNING DO NOT STORE FUEL WITHINHEATER INSTALLATION CLEARANCES WARNING WHEN OPERATING THIS APPLIANCE ASAN OPEN FIRE USE A FIRE SCREEN WARNING OPEN AIR CONTROL AND DAMPERWHEN FITTED BEFORE OPENING FIRINGDOOR CAUTIO...

Страница 3: ... frequencies in the home such as wireless internet or child monitor refer to 11 Change Fan Controller Frequency in the Maintenance Servicing section for details on changing the frequency First few times the appliance is lit it will give off some odorous fumes This is caused by the paint curing Do not touch the paint work while it is curing otherwise it can leave a permanent mark on the appliance O...

Страница 4: ... the air slide 4 5mm The air slide can be adjusted to any position so desired depending on wanted heat output versus burn time Fan may be turned to low speed setting or off if the heater is putting out sufficient heat without the fan on Reload with more wood 1 Open air slide before opening door 2 Rake break up any existing coals 3 Load the wood with the length orientated front to back 4 Better res...

Страница 5: ...k inside of flue prior to each season for any build up of creosote wood tar To do this o First remove the baffle refer to 2 Replacement of Baffle under Maintenance Servicing section o Using a small mirror and torch hold the mirror on an angle below the flue with the torch shining at it and look for black creosote build up If only a fine black powdery layer then that is normal but if built up layer...

Страница 6: ...ught Contact the installer should this happen Trouble starting the fire If all ash has been removed from the firebox then it can upset the supply of air to the base of the fire It can aid the fire by retaining some ash when cleaning out the firebox The purpose of the firebricks in the appliance is to increase thermal mass and to guarantee the longevity of the steel firebox Over time the firebricks...

Страница 7: ...e rod Over time the screws securing the door hinge plate to the heater may loosen resulting in the door dropping i e visually appears on slight angle and no longer 100 horizontal This can result in a poor door seal and unnecessary amounts of oxygen entering the firebox and wood burning too quickly To fix this and reposition the door 1 With the supplied Allen key loosen the two screws on the hinge ...

Страница 8: ...x screws 6 Dispose of the old glass in a responsible manner This task may be easier with the door removed from the appliance and laid horizontally on a work bench 1 Remove any old seal from the door 2 Clean out the groove in the door that the seal was bedded in using a flat end screw driver or equivalent 3 Run a thin bead of clear roof and gutter silicone along the groove 4 Starting at one end pre...

Страница 9: ... To access the remote control receiver B600 B900 Models located in the base unit in the rear panel on the left hand side removed via two screws with a M6 Allen key B605 B905 located underneath at the rear of the base unit in a steel cabinet that can be removed via two screws with a M6 Allen key Fan Controller Remove the battery cover and batteries With a small screwdriver or equivalent change the ...

Страница 10: ......

Страница 11: ......

Страница 12: ...Pecan Engineering Pty Limited 13 Acorn Road Dry Creek South Australia 5094 T 08 8349 8332 F 08 8260 6643 Email info pecan eng com au ...

Отзывы: